All MIBs › APTIS-V2TRAPS-MIB › cvxSlaveSccInserted
cvxSlaveSccInserted
Module: APTIS-V2TRAPS-MIB
OID (symbolic): APTIS-V2TRAPS-MIB::cvxSlaveSccInserted
OID (numeric): 1.3.6.1.4.1.2637.2.5.1.0.76
Node type: NOTIFICATION-TYPE
Description: The master SCC (System Control Card) has detected that the slave SCC has been inserted into the system. File synchronization will start or resume.
See also traps cvxSlaveSccRemoved and cvxFailedSlaveSccRemoved.
This trap carries a severity of 3 (error).
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' APTIS-V2TRAPS-MIB::cvxSlaveSccInserted snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.2637.2.5.1.0.76
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:55078->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (395858726) 45 days, 19:36:27.26 SNMPv2-MIB::snmpTrapOID.0 = OID: APTIS-V2TRAPS-MIB::cvxSlaveSccInserted
Start monitoring Nortel Networks Aptis DSL access concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APTIS-V2TRAPS-MIB::cvxSlaveSccInserted OID value, configure state conditions and alerts, and monitor any Nortel Networks Aptis DSL access concentrator (legacy) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2637 | aptis | APTIS-MIB |
| 1.3.6.1.4.1.2637.2 | aptis_generic | APTIS-MIB |
| 1.3.6.1.4.1.2637.2.5 | aptis_traps | APTIS-MIB |
| 1.3.6.1.4.1.2637.2.5.1 | aptisProtraps | APTIS-TRAPS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2637.2.5.1.0 | aptisProtrapsV2 | APTIS-V2TRAPS-MIB |
| 1.3.6.1.4.1.2637.2.5.1.0.76 | cvxSlaveSccInserted | APTIS-V2TRAPS-MIB |