| OID symbolic | OID numeric | Type | Access | Description |
| acModule | 1.3.6.1.4.1.2785.2.2 | | | Appian Communications OSAP Modules MIB contain the definitions for
module hardware information and status. |
| acModuleTraps | 1.3.6.1.4.1.2785.2.2.0 | | | |
| NTF acModuleCfgMismatchTrap | 1.3.6.1.4.1.2785.2.2.0.1 | | | The configured module type does not match with the actual module present. |
| NTF acModuleResetFailedTrap | 1.3.6.1.4.1.2785.2.2.0.2 | | | The module couldn't be reset. |
| NTF acModuleSwVersionTrap | 1.3.6.1.4.1.2785.2.2.0.3 | | | Two different version of software are currently running within the same
chassis. This is an unsupported operational mode. |
| NTF acModuleRemovalTrap | 1.3.6.1.4.1.2785.2.2.0.4 | | | A module has been removed from this chassis. |
| NTF acModuleInsertedTrap | 1.3.6.1.4.1.2785.2.2.0.5 | | | A module has been inserted into this chassis. |
| NTF acModuleFailureTrap | 1.3.6.1.4.1.2785.2.2.0.6 | | | The module in this slot did not pass diagnostics or has been marked as a failed
board by operational software. |
| acModuleTable | 1.3.6.1.4.1.2785.2.2.1 | | not-accessible | A table containing the module information for each module within the
chassis. This table is automatically created during system initialization
and updated when modules are removed and inserted. When a module is
removed, the row is automatically removed. |
| acModuleEntry | 1.3.6.1.4.1.2785.2.2.1.1 | | not-accessible | Module information record containing hardware, software, firmware, name
data for a specific node.slot within a chassis. Row's in this table are
automatically instantiated at system initialization. |
| ACN acModuleNodeId | 1.3.6.1.4.1.2785.2.2.1.1.1 | AcNodeId | accessible-for-notify | The unique node identification number representing a chassis within a
ring of OSAP's. |
| ACS acModuleSlot | 1.3.6.1.4.1.2785.2.2.1.1.2 | AcSlotNumber | accessible-for-notify | The slot number within the chassis where this module resides. |
| ACM acModuleNumber | 1.3.6.1.4.1.2785.2.2.1.1.3 | AcModuleNumber | accessible-for-notify | The module number within the slot where this module resides. |
| ACA acModuleAdminStatus | 1.3.6.1.4.1.2785.2.2.1.1.4 | AcAdminStatus | read-write | The administrative status. See AcAdminStatus for the semantics. |
| ACM acModuleCfgType | 1.3.6.1.4.1.2785.2.2.1.1.5 | AcModuleType | read-write | The acModuleCfgType field enumeration is used to uniquely identify the
module type which is currently in a slot within the chassis, as
defined by the AppianVista EMS. |
| ACM acModuleType | 1.3.6.1.4.1.2785.2.2.1.1.6 | AcModuleType | read-only | The acModuleType field enumeration is used to uniquely identify the
module type which is currently in a slot within the chassis. |
| ACO acModuleOpStatus | 1.3.6.1.4.1.2785.2.2.1.1.7 | AcOpStatus | read-only | This field indicates the current operational status for the module. Only
the following values are applicable to the module: operational, offline,
initializing, selfTesting, upgrading, standby, shuttingDown and failed. |
| INT acModuleRevision | 1.3.6.1.4.1.2785.2.2.1.1.8 | INTEGER | read-only | Contains the manufacturing revision number for this module. |
| STR acModuleSerialNumber | 1.3.6.1.4.1.2785.2.2.1.1.9 | DisplayString | read-only | A display string representing the manufacturing serial number as stored
in the modules I2C prom. |
| STR acModuleProductionDate | 1.3.6.1.4.1.2785.2.2.1.1.10 | DisplayString | read-only | The date code when this module was manufactured. This field
is read-only and set by manufacturing in the I2C prom. The format used
is YYWW; with YY = year and WW = week. |
| STR acModuleFirmwareName | 1.3.6.1.4.1.2785.2.2.1.1.11 | DisplayString | read-only | This string contains the name of the firmware file resident on the
switch controller file system. Note: Not all modules contain firmware. |
| INT acModuleFirmwareRevision | 1.3.6.1.4.1.2785.2.2.1.1.12 | INTEGER | read-only | The revision of the firmware. |
| C32 acModuleNumberFailuresEx | 1.3.6.1.4.1.2785.2.2.1.1.13 | Counter32 | read-only | The total number of failure events reported by the module. |
| T/F acModuleReset | 1.3.6.1.4.1.2785.2.2.1.1.14 | TruthValue | read-write | This field allows the user to reset a specified module within the
chassis. Note: If resetting the active SCP on which the management
session is active, loss of connection will result as the standby SCP
gains control. |
| INT acModuleNumberPorts | 1.3.6.1.4.1.2785.2.2.1.1.15 | INTEGER | read-only | A count of the total number of ports located on this module. Not all
modules contain user configurable or usable ports. |
| STR acModuleName | 1.3.6.1.4.1.2785.2.2.1.1.16 | DisplayString | read-only | The official human readable name for the type of module indicated by
acModuleType. |
| ACS acModuleSwVersion | 1.3.6.1.4.1.2785.2.2.1.1.17 | AcSwVersion | read-only | The current software version if any which is operational on this module.
This attribute will be NULL if the physical module does not execute a
software image (re: it is controlled by the switch controller). |
| INT acModuleDiagTestMode | 1.3.6.1.4.1.2785.2.2.1.1.18 | INTEGER | read-write | The diagnostics test mode allows the user to select a basic(1),
advanced(2) or stress(3) series of powerup self tests to be run
when the acModuleOpStatus field is changed to selfTesting(4). A
basic(1) test performs a quick self test and is the mode which is
by default selected at powerup. Advanced(2) mode is used to run
a more thorough series of tests and stress(3) mode is used to
execute a system test packet loopback type of powerup test. In
all test modes, the acModuleDiagStatus field contains a unique
results code (Refer to diagnostics utility guide). The results
of a test request is also written as a string to the
acModuleDiagResultString field. |
| INT acModuleDiagStatus | 1.3.6.1.4.1.2785.2.2.1.1.19 | INTEGER | read-only | The unique results code as returned from the test mode issued
via acModuleDiagTestMode. Refer to the diagnostic utility
guide for details. |
| STR acModuleDiagResultString | 1.3.6.1.4.1.2785.2.2.1.1.20 | DisplayString | read-only | The results of the diagnostic test returned as a printable
ASCII string. Refer to the diagnostics utility guide for
details. |
| ACM acModuleActiveSlot | 1.3.6.1.4.1.2785.2.2.1.1.21 | AcMediaSlotNumber | read-only | The slot number within the chassis where the media module that
is driving this module resides. This attribute is set to 0 for
rows in which the module is either not an IO card or is an IO
card that has no appropriate media card present in the chassis. |
| ACM acModulePrimarySlot | 1.3.6.1.4.1.2785.2.2.1.1.22 | AcMediaSlotNumber | read-only | The slot number within the chassis where the primary media module that
could drive this module resides. This attribute is set to 0 for
rows in which the module is either not an IO card or is an IO
card that has no appropriate media card present in the chassis. |
| ACM acModuleBackupSlot | 1.3.6.1.4.1.2785.2.2.1.1.23 | AcMediaSlotNumber | read-only | The slot number within the chassis where the backup media module that
could drive this module resides. This attribute is set to 0 for
rows in which the module is either not an IO card or is an IO
card that has no appropriate media card present in the chassis. |