APPACCELERATION-STATUS-MIB :: wsWanOutOctets

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAPPACCELERATION-STATUS-MIBwsWanOutOctets

wsWanOutOctets

Module: APPACCELERATION-STATUS-MIB

OID (symbolic): APPACCELERATION-STATUS-MIB::wsWanOutOctets

OID (numeric): 1.3.6.1.4.1.3845.30.4.1.1.1.10

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Number of accelerated octets transmitted on the WAN side. This is also available in the GUI Usage Graph page.

What is wsWanOutOctets?

Counts the total number of accelerated bytes transmitted on the WAN interface of the appliance, useful for tracking outbound WAN traffic volume.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3845.30.4.1.1.1.10
snmpwalk -v2c -c public <target> APPACCELERATION-STATUS-MIB::wsWanOutOctets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3845.30.4.1.1.1.10.1
snmpget -v2c -c public <target> APPACCELERATION-STATUS-MIB::wsWanOutOctets.1

Start monitoring Citrix Application Acceleration WAN-optimization appliances (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APPACCELERATION-STATUS-MIB::wsWanOutOctets OID value, configure state conditions and alerts, and monitor any Citrix Application Acceleration WAN-optimization appliances (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Citrix Application Acceleration WAN-optimization appliance (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type wsWanOutOctets into the Find box to locate it in the OID tree, then select it and click OK. It reports the number of accelerated octets transmitted on the WAN side. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in Octets), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3845citrixCITRIX-COMMON-MIB
1.3.6.1.4.1.3845.30appAccelerationAPPACCELERATION-SMI
1.3.6.1.4.1.3845.30.4appAccelerationMgmtAPPACCELERATION-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3845.30.4.1appAccelerationStatusMIBAPPACCELERATION-STATUS-MIB
1.3.6.1.4.1.3845.30.4.1.1wsStatusMIBObjectsAPPACCELERATION-STATUS-MIB
1.3.6.1.4.1.3845.30.4.1.1.1wsStatusMIBScalarsAPPACCELERATION-STATUS-MIB
1.3.6.1.4.1.3845.30.4.1.1.1.10wsWanOutOctetsAPPACCELERATION-STATUS-MIB