All MIBs › ANS-GS-MIB
Category: Device Management
Description: ANS CO+RE gateway services management for high-speed network interconnection.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ANS-GS-MIB?
ANS-GS-MIB is an Advanced Network Systems (broadband access equipment, built on ANS-COMMON-MIB/ANS-EQUIPMENT-MIB) proprietary MIB reporting ATM user-port and service-port bandwidth/addressing detail on a subscriber access node (NIU/STU). Its user-port table, keyed by system-node/subrack/position/index, records port type, max/available downstream/upstream bandwidth, VPI/VCI ranges, label, operational/admin status, usage state, and ATM format, while a companion service-port table extends similar fields. As a configuration/status MIB it lets an administrator confirm available ATM bandwidth and VPI/VCI range on a subscriber access port. It is deployed on Advanced Network Systems broadband access nodes. Engineers can download the ANS-GS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ANS-GS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Advanced Network Systems broadband access nodes
Monitoring Examples
An administrator checks ansAccessUserPortAvailBwDs and ansAccessUserPortMaxVpi to confirm remaining ATM bandwidth and VPI range on a subscriber access port.
What Can Be Monitored
- ATM port bandwidth and VPI/VCI range configuration
This MIB depends on
Related MIBs
Imported Objects
From ANS-COMMON-MIB
| DateAndTime | |
| RowPointer | |
| RowStatus | |
| mlpmpR115 | OBJECT-IDENTITY |
From ANS-EQUIPMENT-MIB
| ansBoardPosition | OBJECT-TYPE |
| ansBoardSubrackIndex | OBJECT-TYPE |
| ansBoardSystemNodeIndex | OBJECT-TYPE |
From RFC1213-MIB
| DisplayString |
From SNMPv2-SMI
| IpAddress | |
| OBJECT-TYPE |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| connections | 1.3.6.1.4.1.193.96.115.4 | |||
| accessUserPort | 1.3.6.1.4.1.193.96.115.4.1 | |||
| ansAccessUserPortTable | 1.3.6.1.4.1.193.96.115.4.1.1 | not-accessible | Entries in the ansAccessUserPortTable represents the physical ATM interface towards the STU located in the NIU and will be of type 'ATM'. | |
| ansAccessUserPortEntry | 1.3.6.1.4.1.193.96.115.4.1.1.1 | not-accessible | ||
| INT ansAccessUserPortSystemNode | 1.3.6.1.4.1.193.96.115.4.1.1.1.1 | INTEGER | read-only | Reference to the system node the user port is contained within. |
| INT ansAccessUserPortSubrack | 1.3.6.1.4.1.193.96.115.4.1.1.1.2 | INTEGER | read-only | Reference to the subrack the user port belongs to. |
| INT ansAccessUserPortPosition | 1.3.6.1.4.1.193.96.115.4.1.1.1.3 | INTEGER | read-only | Reference to the board the user port belongs to. |
| INT ansAccessUserPortIndex | 1.3.6.1.4.1.193.96.115.4.1.1.1.4 | INTEGER | read-only | Reference to the interface within the board. |
| ANS ansAccessUserPortType | 1.3.6.1.4.1.193.96.115.4.1.1.1.5 | AnsPortType | read-only | Indicates the type of physical interface that is connected to the port. |
| INT ansAccessUserPortMaxBwDs | 1.3.6.1.4.1.193.96.115.4.1.1.1.6 | INTEGER | read-only | Maximum cell rate this port is capable of in the downstream direction. |
| INT ansAccessUserPortMaxBwUs | 1.3.6.1.4.1.193.96.115.4.1.1.1.7 | INTEGER | read-only | Maximum cell rate this port is capable of in the upstream direction. |
| INT ansAccessUserPortAvailBwDs | 1.3.6.1.4.1.193.96.115.4.1.1.1.8 | INTEGER | read-only | Available bandwidth in cells per second over the port in the downstream direction. |
| INT ansAccessUserPortAvailBwUs | 1.3.6.1.4.1.193.96.115.4.1.1.1.9 | INTEGER | read-only | Available bandwidth in cells per second over the port in the upstream direction. |
| INT ansAccessUserPortMinVpi | 1.3.6.1.4.1.193.96.115.4.1.1.1.10 | INTEGER | read-only | The smallest VPI accepted in both directions through this user port. |
| INT ansAccessUserPortMaxVpi | 1.3.6.1.4.1.193.96.115.4.1.1.1.11 | INTEGER | read-only | The largest VPI accepted in both directions through this user port. |
| INT ansAccessUserPortMinVci | 1.3.6.1.4.1.193.96.115.4.1.1.1.12 | INTEGER | read-only | The smallest VCI accepted in both directions through this user port. |
| INT ansAccessUserPortMaxVci | 1.3.6.1.4.1.193.96.115.4.1.1.1.13 | INTEGER | read-only | The largest VCI accepted in both directions through this user port. |
| STR ansAccessUserPortLabel | 1.3.6.1.4.1.193.96.115.4.1.1.1.14 | DisplayString | read-write | A settable name or description of this user port. |
| INT ansAccessUserPortOperStatus | 1.3.6.1.4.1.193.96.115.4.1.1.1.15 | INTEGER | read-only | |
| INT ansAccessUserPortAdminStatus | 1.3.6.1.4.1.193.96.115.4.1.1.1.16 | INTEGER | read-write | |
| INT ansAccessUserPortUsageState | 1.3.6.1.4.1.193.96.115.4.1.1.1.17 | INTEGER | read-only | |
| INT ansAccessUserPortAtmFormat | 1.3.6.1.4.1.193.96.115.4.1.1.1.18 | INTEGER | read-write | |
| accessServicePort | 1.3.6.1.4.1.193.96.115.4.2 | |||
| ansAccessServicePortTable | 1.3.6.1.4.1.193.96.115.4.2.1 | not-accessible | Entries in the ansAccessServicePortTable represents a bidirectional STM1 port in the RF-shelf. | |
| ansAccessServicePortEntry | 1.3.6.1.4.1.193.96.115.4.2.1.1 | not-accessible | ||
| INT ansAccessServicePortSystemNode | 1.3.6.1.4.1.193.96.115.4.2.1.1.1 | INTEGER | read-only | Indicates wich system node the port is contained within. |
| INT ansAccessServicePortSubrack | 1.3.6.1.4.1.193.96.115.4.2.1.1.2 | INTEGER | read-only | Indicates wich subrack the port is contained within. |
| INT ansAccessServicePortPosition | 1.3.6.1.4.1.193.96.115.4.2.1.1.3 | INTEGER | read-only | Indicates the slot position within the subrack |
| INT ansAccessServicePortIndex | 1.3.6.1.4.1.193.96.115.4.2.1.1.4 | INTEGER | read-only | Indicates physical port index on the board. |
| STR ansAccessServicePortLabel | 1.3.6.1.4.1.193.96.115.4.2.1.1.5 | DisplayString | read-write | Text string that may be used to name the port. |
| INT ansAccessServicePortMaxBwDs | 1.3.6.1.4.1.193.96.115.4.2.1.1.6 | INTEGER | read-only | Maximum cell rate this port is capable of in the downstream direction. |
| INT ansAccessServicePortMaxBwUs | 1.3.6.1.4.1.193.96.115.4.2.1.1.7 | INTEGER | read-only | Maximum cell rate this port is capable of in the upstream direction. |
| INT ansAccessServicePortAvailBwDs | 1.3.6.1.4.1.193.96.115.4.2.1.1.8 | INTEGER | read-only | Available bandwidth in cells per second over the port in the downstream direction. |
| INT ansAccessServicePortAvailBwUs | 1.3.6.1.4.1.193.96.115.4.2.1.1.9 | INTEGER | read-only | Available bandwidth in cells per second over the port in the upstream direction. |
| INT ansAccessServicePortMinVpi | 1.3.6.1.4.1.193.96.115.4.2.1.1.10 | INTEGER | read-only | The smallest VPI value possible over this port in both directions. |
| INT ansAccessServicePortMaxVpi | 1.3.6.1.4.1.193.96.115.4.2.1.1.11 | INTEGER | read-only | The largest VPI value possible over this port in both directions. |
| INT ansAccessServicePortMinVci | 1.3.6.1.4.1.193.96.115.4.2.1.1.12 | INTEGER | read-only | The smallest VCI value possible over this port in both directions. |
| INT ansAccessServicePortMaxVci | 1.3.6.1.4.1.193.96.115.4.2.1.1.13 | INTEGER | read-only | The largest VCI value possible over this port in both directions. |
| INT ansAccessServicePortOperStatus | 1.3.6.1.4.1.193.96.115.4.2.1.1.14 | INTEGER | read-only | |
| INT ansAccessServicePortAdminStatus | 1.3.6.1.4.1.193.96.115.4.2.1.1.15 | INTEGER | read-write | |
| INT ansAccessServicePortUsageState | 1.3.6.1.4.1.193.96.115.4.2.1.1.16 | INTEGER | read-only | |
| INT ansAccessServicePortAtmFormat | 1.3.6.1.4.1.193.96.115.4.2.1.1.17 | INTEGER | read-write | |
| ANS ansAccessServicePortType | 1.3.6.1.4.1.193.96.115.4.2.1.1.18 | AnsPortType | read-only | Indicates the type of physical interface that is connected to the service port. |
| accessServiceUserPort | 1.3.6.1.4.1.193.96.115.4.3 | |||
| ansAccessServiceUserPortTable | 1.3.6.1.4.1.193.96.115.4.3.1 | not-accessible | Entries in the ansAccessServiceUserPortTable represents a bidirectional STM1 port in the RF-shelf. | |
| ansAccessServiceUserPortEntry | 1.3.6.1.4.1.193.96.115.4.3.1.1 | not-accessible | ||
| INT ansAccessServiceUserPortSystemNode | 1.3.6.1.4.1.193.96.115.4.3.1.1.1 | INTEGER | read-only | Indicates wich system node the port is contained within. |
| INT ansAccessServiceUserPortSubrack | 1.3.6.1.4.1.193.96.115.4.3.1.1.2 | INTEGER | read-only | Indicates wich subrack the port is contained within. |
| INT ansAccessServiceUserPortPosition | 1.3.6.1.4.1.193.96.115.4.3.1.1.3 | INTEGER | read-only | Indicates the slot position within the subrack |
| INT ansAccessServiceUserPortIndex | 1.3.6.1.4.1.193.96.115.4.3.1.1.4 | INTEGER | read-only | Indicates physical port index on the board. |
| STR ansAccessServiceUserPortLabel | 1.3.6.1.4.1.193.96.115.4.3.1.1.5 | DisplayString | read-write | Text string that may be used to name the port. |
| INT ansAccessServiceUserPortMaxBwDs | 1.3.6.1.4.1.193.96.115.4.3.1.1.6 | INTEGER | read-only | Maximum cell rate this port is capable of in the downstream direction. |
| INT ansAccessServiceUserPortMaxBwUs | 1.3.6.1.4.1.193.96.115.4.3.1.1.7 | INTEGER | read-only | Maximum cell rate this port is capable of in the upstream direction. |
| INT ansAccessServiceUserPortAvailBwDs | 1.3.6.1.4.1.193.96.115.4.3.1.1.8 | INTEGER | read-only | Available bandwidth in cells per second over the port in the downstream direction. |
| INT ansAccessServiceUserPortAvailBwUs | 1.3.6.1.4.1.193.96.115.4.3.1.1.9 | INTEGER | read-only | Available bandwidth in cells per second over the port in the upstream direction. |
| INT ansAccessServiceUserPortMinVpi | 1.3.6.1.4.1.193.96.115.4.3.1.1.10 | INTEGER | read-only | The smallest VPI value possible over this port in both directions. |
| INT ansAccessServiceUserPortMaxVpi | 1.3.6.1.4.1.193.96.115.4.3.1.1.11 | INTEGER | read-only | The largest VPI value possible over this port in both directions. |
| INT ansAccessServiceUserPortMinVci | 1.3.6.1.4.1.193.96.115.4.3.1.1.12 | INTEGER | read-only | The smallest VCI value possible over this port in both directions. |
| INT ansAccessServiceUserPortMaxVci | 1.3.6.1.4.1.193.96.115.4.3.1.1.13 | INTEGER | read-only | The largest VCI value possible over this port in both directions. |
| INT ansAccessServiceUserPortOperStatus | 1.3.6.1.4.1.193.96.115.4.3.1.1.14 | INTEGER | read-only | |
| INT ansAccessServiceUserPortAdminStatus | 1.3.6.1.4.1.193.96.115.4.3.1.1.15 | INTEGER | read-write | |
| INT ansAccessServiceUserPortUsageState | 1.3.6.1.4.1.193.96.115.4.3.1.1.16 | INTEGER | read-only | |
| INT ansAccessServiceUserPortAtmFormat | 1.3.6.1.4.1.193.96.115.4.3.1.1.17 | INTEGER | read-write | |
| ANS ansAccessServiceUserPortType | 1.3.6.1.4.1.193.96.115.4.3.1.1.18 | AnsPortType | read-only | Indicates the type of physical interface that is connected to the service-user port. |
| accessInternalPort | 1.3.6.1.4.1.193.96.115.4.4 | |||
| ansAccessInternalPortTable | 1.3.6.1.4.1.193.96.115.4.4.1 | not-accessible | Entries in the ansAccessInternalPortTable represents a bidirectional STM1 port | |
| ansAccessInternalPortEntry | 1.3.6.1.4.1.193.96.115.4.4.1.1 | not-accessible | ||
| INT ansAccessInternalPortSystemNode | 1.3.6.1.4.1.193.96.115.4.4.1.1.1 | INTEGER | read-only | Indicates wich system node the port is contained within. |
| INT ansAccessInternalPortSubrack | 1.3.6.1.4.1.193.96.115.4.4.1.1.2 | INTEGER | read-only | Indicates wich subrack the port is contained within. |
| INT ansAccessInternalPortPosition | 1.3.6.1.4.1.193.96.115.4.4.1.1.3 | INTEGER | read-only | Indicates the slot position within the subrack |
| INT ansAccessInternalPortIndex | 1.3.6.1.4.1.193.96.115.4.4.1.1.4 | INTEGER | read-only | Indicates physical port index on the board. |
| STR ansAccessInternalPortLabel | 1.3.6.1.4.1.193.96.115.4.4.1.1.5 | DisplayString | read-write | Text string that may be used to name the port. |
| INT ansAccessInternalPortMaxBwDs | 1.3.6.1.4.1.193.96.115.4.4.1.1.6 | INTEGER | read-only | Maximum cell rate this port is capable of in the downstream direction. |
| INT ansAccessInternalPortMaxBwUs | 1.3.6.1.4.1.193.96.115.4.4.1.1.7 | INTEGER | read-only | Maximum cell rate this port is capable of in the upstream direction. |
| INT ansAccessInternalPortAvailBwDs | 1.3.6.1.4.1.193.96.115.4.4.1.1.8 | INTEGER | read-only | Available bandwidth in cells per second over the port in the downstream direction. |
| INT ansAccessInternalPortAvailBwUs | 1.3.6.1.4.1.193.96.115.4.4.1.1.9 | INTEGER | read-only | Available bandwidth in cells per second over the port in the upstream direction. |
| INT ansAccessInternalPortMinVpi | 1.3.6.1.4.1.193.96.115.4.4.1.1.10 | INTEGER | read-only | The smallest VPI value possible over this port in both directions. |
| INT ansAccessInternalPortMaxVpi | 1.3.6.1.4.1.193.96.115.4.4.1.1.11 | INTEGER | read-only | The largest VPI value possible over this port in both directions. |
| INT ansAccessInternalPortMinVci | 1.3.6.1.4.1.193.96.115.4.4.1.1.12 | INTEGER | read-only | The smallest VCI value possible over this port in both directions. |
| INT ansAccessInternalPortMaxVci | 1.3.6.1.4.1.193.96.115.4.4.1.1.13 | INTEGER | read-only | The largest VCI value possible over this port in both directions. |
| INT ansAccessInternalPortOperStatus | 1.3.6.1.4.1.193.96.115.4.4.1.1.14 | INTEGER | read-only | |
| INT ansAccessInternalPortAdminStatus | 1.3.6.1.4.1.193.96.115.4.4.1.1.15 | INTEGER | read-write | |
| INT ansAccessInternalPortUsageState | 1.3.6.1.4.1.193.96.115.4.4.1.1.16 | INTEGER | read-only | |
| INT ansAccessInternalPortAtmFormat | 1.3.6.1.4.1.193.96.115.4.4.1.1.17 | INTEGER | read-write | |
| ANS ansAccessInternalPortType | 1.3.6.1.4.1.193.96.115.4.4.1.1.18 | AnsPortType | read-only | Indicates the type of physical interface that is connected to the internal port. |
| ansAtmCreateCC | 1.3.6.1.4.1.193.96.115.4.5 | |||
| ansAtmCreateCCTable | 1.3.6.1.4.1.193.96.115.4.5.1 | not-accessible | Entries in the ansAtmCreateCCTable represents ATM VP and VP cross-connections between access user ports and access service ports. | |
| ansAtmCreateCCEntry | 1.3.6.1.4.1.193.96.115.4.5.1.1 | not-accessible | ||
| INT ansAtmCCAUPSystemNode | 1.3.6.1.4.1.193.96.115.4.5.1.1.1 | INTEGER | read-only | Reference to the system node the access user port belongs to. |
| INT ansAtmCCAUPSubrack | 1.3.6.1.4.1.193.96.115.4.5.1.1.2 | INTEGER | read-only | Reference to the subrack the access user port belongs to. |
| INT ansAtmCCAUPPosition | 1.3.6.1.4.1.193.96.115.4.5.1.1.3 | INTEGER | read-only | Reference to user port's slot position within the subrack. |
| INT ansAtmCCAUPIndex | 1.3.6.1.4.1.193.96.115.4.5.1.1.4 | INTEGER | read-only | Reference to user port's physical interface on the board. |
| INT ansAtmCCAUPVPI | 1.3.6.1.4.1.193.96.115.4.5.1.1.5 | INTEGER | read-only | VPI value at the user port. (100001 = any) Assigned by system. |
| INT ansAtmCCAUPVCI | 1.3.6.1.4.1.193.96.115.4.5.1.1.6 | INTEGER | read-only | VCI value at the user port. (100000 = undefined) Not applicable. (100001 = any) Assigned by system. |
| INT ansAtmCCASPSubrack | 1.3.6.1.4.1.193.96.115.4.5.1.1.7 | INTEGER | read-write | Reference to the subrack the access service port belongs to. |
| INT ansAtmCCASPPosition | 1.3.6.1.4.1.193.96.115.4.5.1.1.8 | INTEGER | read-write | Reference to access service port port's slot position within the subrack. |
| INT ansAtmCCASPIndex | 1.3.6.1.4.1.193.96.115.4.5.1.1.9 | INTEGER | read-write | Reference to access service port's physical interface on the board. |
| INT ansAtmCCASPVPI | 1.3.6.1.4.1.193.96.115.4.5.1.1.10 | INTEGER | read-write | VPI value at the access service port. (100001 = any) Assigned by system. |
| INT ansAtmCCASPVCI | 1.3.6.1.4.1.193.96.115.4.5.1.1.11 | INTEGER | read-write | VCI value at the access service port. (100000 = undefined) Not applicable. (100001 = any) Assigned by system. |
| ANS ansAtmCCType | 1.3.6.1.4.1.193.96.115.4.5.1.1.12 | AnsCCType | read-write | Indicates if the entry is a VC or VP cross-connection. |
| ANS ansAtmCCServiceClass | 1.3.6.1.4.1.193.96.115.4.5.1.1.13 | AnsCCServiceClass | read-write | Indicates ATM bearer service type. cbr1: Highest priority constant bit-rate service, used for circuit emulated POTS. cbr2: Lower priority constant bit-rate service, used for video transmissions. ubr: Lowest priority service, used for datacom. |
| ANS ansAtmCCSourceType | 1.3.6.1.4.1.193.96.115.4.5.1.1.14 | AnsCCSourceType | read-write | Indicates the type of service that is transported on top of the ATM layer. |
| INT ansAtmCCServiceType | 1.3.6.1.4.1.193.96.115.4.5.1.1.15 | INTEGER | read-write | Indicates the type of connection ATM or ETHERNET. |
| INT ansAtmCCPcrAtoB | 1.3.6.1.4.1.193.96.115.4.5.1.1.16 | INTEGER | read-write | Bandwidth in cells per second for the cross-connection in the downstream direction. UBR connections may be given any positive cell rate. The -1 indicates the unspecified value. |
| INT ansAtmCCPcrBtoA | 1.3.6.1.4.1.193.96.115.4.5.1.1.17 | INTEGER | read-write | Bandwidth in cells per second for the cross-connection in the upstream direction. UBR connections may be given any positive cell rate. The -1 indicates the unspecified value. |
| ANS ansAtmCCMulti | 1.3.6.1.4.1.193.96.115.4.5.1.1.18 | AnsCCMulti | read-write | Indicates if the cross- connection is part of a point-to-point or a point-to-multi point connection. |
| ANS ansAtmCCAdminStatus | 1.3.6.1.4.1.193.96.115.4.5.1.1.19 | AnsCCAdminStatus | read-write | Indicetes the administrative state of the cross-connection. |
| ROW ansAtmCCRowStatus | 1.3.6.1.4.1.193.96.115.4.5.1.1.20 | RowStatus | read-write | Used to create cross-connect. To create a cross-connect ansCCRowStatus must be set to 'createAndGo'. |
| ansCeAtmCreateCC | 1.3.6.1.4.1.193.96.115.4.6 | |||
| ansCeAtmCreateCCTable | 1.3.6.1.4.1.193.96.115.4.6.1 | not-accessible | Entries in the ansCeAtmCreateCCTable represents ATM VP and VP cross-connections between access user ports and access service ports. | |
| ansCeAtmCreateCCEntry | 1.3.6.1.4.1.193.96.115.4.6.1.1 | not-accessible | ||
| INT ansCeAtmCCAUPSystemNode | 1.3.6.1.4.1.193.96.115.4.6.1.1.1 | INTEGER | read-only | Reference to the system node the access user port belongs to. |
| INT ansCeAtmCCAUPSubrack | 1.3.6.1.4.1.193.96.115.4.6.1.1.2 | INTEGER | read-only | Reference to the subrack the access user port belongs to. |
| INT ansCeAtmCCAUPPosition | 1.3.6.1.4.1.193.96.115.4.6.1.1.3 | INTEGER | read-only | Reference to user port's slot position within the subrack. |
| INT ansCeAtmCCAUPIndex | 1.3.6.1.4.1.193.96.115.4.6.1.1.4 | INTEGER | read-only | Reference to user port's physical interface on the board. |
| INT ansCeAtmCCAUPVPI | 1.3.6.1.4.1.193.96.115.4.6.1.1.5 | INTEGER | read-only | VPI value at the user port. (100001 = any) Assigned by system. |
| INT ansCeAtmCCAUPVCI | 1.3.6.1.4.1.193.96.115.4.6.1.1.6 | INTEGER | read-only | VCI value at the user port. (100000 = undefined) Not applicable. (100001 = any) Assigned by system. |
| INT ansCeAtmCCASPSubrack | 1.3.6.1.4.1.193.96.115.4.6.1.1.7 | INTEGER | read-write | Reference to the subrack the access service port belongs to. |
| INT ansCeAtmCCASPPosition | 1.3.6.1.4.1.193.96.115.4.6.1.1.8 | INTEGER | read-write | Reference to access service port port's slot position within the subrack. |
| INT ansCeAtmCCASPIndex | 1.3.6.1.4.1.193.96.115.4.6.1.1.9 | INTEGER | read-write | Reference to access service port's physical interface on the board. |
| INT ansCeAtmCCASPVPI | 1.3.6.1.4.1.193.96.115.4.6.1.1.10 | INTEGER | read-write | VPI value at the access service port. (100001 = any) Assigned by system. |
| INT ansCeAtmCCASPVCI | 1.3.6.1.4.1.193.96.115.4.6.1.1.11 | INTEGER | read-write | VCI value at the access service port. (100000 = undefined) Not applicable. (100001 = any) Assigned by system. |
| ANS ansCeAtmCCType | 1.3.6.1.4.1.193.96.115.4.6.1.1.12 | AnsCCType | read-write | Indicates if the entry is a VC or VP cross-connection. |
| ANS ansCeAtmCCServiceClass | 1.3.6.1.4.1.193.96.115.4.6.1.1.13 | AnsCCServiceClass | read-write | Indicates ATM bearer service type. cbr1: Highest priority constant bit-rate service, used for circuit emulated POTS. cbr2: Lower priority constant bit-rate service, used for video transmissions. ubr: Lowest priority service, used for datacom. |
| ANS ansCeAtmCCSourceType | 1.3.6.1.4.1.193.96.115.4.6.1.1.14 | AnsCCSourceType | read-write | Indicates the type of service that is transported on top of the ATM layer. |
| INT ansCeAtmCCPcrAtoB | 1.3.6.1.4.1.193.96.115.4.6.1.1.15 | INTEGER | read-write | Bandwidth in cells per second for the cross-connection in the downstream direction. UBR connections may be given any positive cell rate. The -1 indicetes the unspecified value. |
| INT ansCeAtmCCPcrBtoA | 1.3.6.1.4.1.193.96.115.4.6.1.1.16 | INTEGER | read-write | Bandwidth in cells per second for the cross-connection in the upstream direction. UBR connections may be given any positive cell rate. The -1 indicates the unspecified value. |
| ANS ansCeAtmCCMulti | 1.3.6.1.4.1.193.96.115.4.6.1.1.17 | AnsCCMulti | read-write | Indicates if the cross- connection is part of a point-to-point or a point-to-multi point connection. |
| ANS ansCeAtmCCAdminStatus | 1.3.6.1.4.1.193.96.115.4.6.1.1.18 | AnsCCAdminStatus | read-write | Indicetes the administrative state of the cross-connection. |
| STR ansCeAtmCCTimeSlotPa | 1.3.6.1.4.1.193.96.115.4.6.1.1.19 | DisplayString | read-write | The TS list must have the format: [int1,int2,...]. not_used (unstructured) |
| ANS ansCeAtmCCTypePa | 1.3.6.1.4.1.193.96.115.4.6.1.1.20 | AnsAal1ParsType | read-write | |
| INT ansCeAtmCCFillLevelPa | 1.3.6.1.4.1.193.96.115.4.6.1.1.21 | INTEGER | read-write | |
| INT ansCeAtmCCCdvtPa | 1.3.6.1.4.1.193.96.115.4.6.1.1.22 | INTEGER | read-write | |
| INT ansCeAtmCCMaxBuffSizePa | 1.3.6.1.4.1.193.96.115.4.6.1.1.23 | INTEGER | read-write | (-1) undefined |
| ANS ansCeAtmCCTcModePa | 1.3.6.1.4.1.193.96.115.4.6.1.1.24 | AnsAal1ParsTcMode | read-write | |
| ANS ansCeAtmCCTcTypePa | 1.3.6.1.4.1.193.96.115.4.6.1.1.25 | AnsAal1ParsTcType | read-write | |
| INT ansCeAtmCCTcBtoAPa | 1.3.6.1.4.1.193.96.115.4.6.1.1.26 | INTEGER | read-write | (-1) undefined |
| INT ansCeAtmCCTcAtoBPa | 1.3.6.1.4.1.193.96.115.4.6.1.1.27 | INTEGER | read-write | (-1) undefined |
| ROW ansCeAtmCCRowStatus | 1.3.6.1.4.1.193.96.115.4.6.1.1.28 | RowStatus | read-write | Used to create cross-connect. To create a cross-connect ansCCRowStatus must be set to 'createAndGo'. |
| ansCeCeCreateCC | 1.3.6.1.4.1.193.96.115.4.7 | |||
| ansCeCeCreateCCTable | 1.3.6.1.4.1.193.96.115.4.7.1 | not-accessible | Entries in the ansCeCeCreateCCTable represents ATM VP and VP cross-connections between access user ports and access service ports. | |
| ansCeCeCreateCCEntry | 1.3.6.1.4.1.193.96.115.4.7.1.1 | not-accessible | ||
| INT ansCeCeCCAUPSystemNode | 1.3.6.1.4.1.193.96.115.4.7.1.1.1 | INTEGER | read-only | Reference to the system node the access user port belongs to. |
| INT ansCeCeCCAUPSubrack | 1.3.6.1.4.1.193.96.115.4.7.1.1.2 | INTEGER | read-only | Reference to the subrack the access user port belongs to. |
| INT ansCeCeCCAUPPosition | 1.3.6.1.4.1.193.96.115.4.7.1.1.3 | INTEGER | read-only | Reference to user port's slot position within the subrack. |
| INT ansCeCeCCAUPIndex | 1.3.6.1.4.1.193.96.115.4.7.1.1.4 | INTEGER | read-only | Reference to user port's physical interface on the board. |
| INT ansCeCeCCAUPVPI | 1.3.6.1.4.1.193.96.115.4.7.1.1.5 | INTEGER | read-only | VPI value at the user port. (100001 = any) Assigned by system. |
| INT ansCeCeCCAUPVCI | 1.3.6.1.4.1.193.96.115.4.7.1.1.6 | INTEGER | read-only | VCI value at the user port. (100000 = undefined) Not applicable. (100001 = any) Assigned by system. |
| INT ansCeCeCCASPSubrack | 1.3.6.1.4.1.193.96.115.4.7.1.1.7 | INTEGER | read-write | Reference to the subrack the access service port belongs to. |
| INT ansCeCeCCASPPosition | 1.3.6.1.4.1.193.96.115.4.7.1.1.8 | INTEGER | read-write | Reference to access service port port's slot position within the subrack. |
| INT ansCeCeCCASPIndex | 1.3.6.1.4.1.193.96.115.4.7.1.1.9 | INTEGER | read-write | Reference to access service port's physical interface on the board. |
| INT ansCeCeCCASPVPI | 1.3.6.1.4.1.193.96.115.4.7.1.1.10 | INTEGER | read-write | VPI value at the access service port. (100001 = any) Assigned by system. |
| INT ansCeCeCCASPVCI | 1.3.6.1.4.1.193.96.115.4.7.1.1.11 | INTEGER | read-write | VCI value at the access service port. (100000 = undefined) Not applicable. (100001 = any) Assigned by system. |
| ANS ansCeCeCCType | 1.3.6.1.4.1.193.96.115.4.7.1.1.12 | AnsCCType | read-write | Indicates if the entry is a VC or VP cross-connection. |
| ANS ansCeCeCCServiceClass | 1.3.6.1.4.1.193.96.115.4.7.1.1.13 | AnsCCServiceClass | read-write | Indicates ATM bearer service type. cbr1: Highest priority constant bit-rate service, used for circuit emulated POTS. cbr2: Lower priority constant bit-rate service, used for video transmissions. ubr: Lowest priority service, used for datacom. |
| ANS ansCeCeCCSourceType | 1.3.6.1.4.1.193.96.115.4.7.1.1.14 | AnsCCSourceType | read-write | Indicates the type of service that is transported on top of the ATM layer. |
| INT ansCeCeCCPcrAtoB | 1.3.6.1.4.1.193.96.115.4.7.1.1.15 | INTEGER | read-write | Bandwidth in cells per second for the cross-connection in the downstream direction. UBR connections may be given any positive cell rate. The -1 indicetes the unspecified value. |
| INT ansCeCeCCPcrBtoA | 1.3.6.1.4.1.193.96.115.4.7.1.1.16 | INTEGER | read-write | Bandwidth in cells per second for the cross-connection in the upstream direction. UBR connections may be given any positive cell rate. The -1 indicates the unspecified value. |
| ANS ansCeCeCCMulti | 1.3.6.1.4.1.193.96.115.4.7.1.1.17 | AnsCCMulti | read-write | Indicates if the cross- connection is part of a point-to-point or a point-to-multi point connection. |
| ANS ansCeCeCCAdminStatus | 1.3.6.1.4.1.193.96.115.4.7.1.1.18 | AnsCCAdminStatus | read-write | |
| STR ansCeCeCCTimeSlotPa | 1.3.6.1.4.1.193.96.115.4.7.1.1.19 | DisplayString | read-write | The TS list must have the format: [int1,int2,...]. not_used (unstructured) |
| ANS ansCeCeCCTypePa | 1.3.6.1.4.1.193.96.115.4.7.1.1.20 | AnsAal1ParsType | read-write | |
| INT ansCeCeCCFillLevelPa | 1.3.6.1.4.1.193.96.115.4.7.1.1.21 | INTEGER | read-write | |
| INT ansCeCeCCCdvtPa | 1.3.6.1.4.1.193.96.115.4.7.1.1.22 | INTEGER | read-write | |
| INT ansCeCeCCMaxBuffSizePa | 1.3.6.1.4.1.193.96.115.4.7.1.1.23 | INTEGER | read-write | (-1) undefined |
| ANS ansCeCeCCTcModePa | 1.3.6.1.4.1.193.96.115.4.7.1.1.24 | AnsAal1ParsTcMode | read-write | |
| ANS ansCeCeCCTcTypePa | 1.3.6.1.4.1.193.96.115.4.7.1.1.25 | AnsAal1ParsTcType | read-write | |
| INT ansCeCeCCTcBtoAPa | 1.3.6.1.4.1.193.96.115.4.7.1.1.26 | INTEGER | read-write | (-1) undefined |
| INT ansCeCeCCTcAtoBPa | 1.3.6.1.4.1.193.96.115.4.7.1.1.27 | INTEGER | read-write | (-1) undefined |
| STR ansCeCeCCTimeSlotPb | 1.3.6.1.4.1.193.96.115.4.7.1.1.28 | DisplayString | read-write | The TS list must have the format: [int1,int2,...]. not_used (unstructured) |
| ANS ansCeCeCCTypePb | 1.3.6.1.4.1.193.96.115.4.7.1.1.29 | AnsAal1ParsType | read-write | |
| INT ansCeCeCCFillLevelPb | 1.3.6.1.4.1.193.96.115.4.7.1.1.30 | INTEGER | read-write | |
| INT ansCeCeCCCdvtPb | 1.3.6.1.4.1.193.96.115.4.7.1.1.31 | INTEGER | read-write | |
| INT ansCeCeCCMaxBuffSizePb | 1.3.6.1.4.1.193.96.115.4.7.1.1.32 | INTEGER | read-write | (-1) undefined |
| ANS ansCeCeCCTcModePb | 1.3.6.1.4.1.193.96.115.4.7.1.1.33 | AnsAal1ParsTcMode | read-write | |
| ANS ansCeCeCCTcTypePb | 1.3.6.1.4.1.193.96.115.4.7.1.1.34 | AnsAal1ParsTcType | read-write | |
| INT ansCeCeCCTcBtoAPb | 1.3.6.1.4.1.193.96.115.4.7.1.1.35 | INTEGER | read-write | (-1) undefined |
| INT ansCeCeCCTcAtoBPb | 1.3.6.1.4.1.193.96.115.4.7.1.1.36 | INTEGER | read-write | (-1) undefined |
| ROW ansCeCeCCRowStatus | 1.3.6.1.4.1.193.96.115.4.7.1.1.37 | RowStatus | read-write | Used to create cross-connect. To create a cross-connect ansCCRowStatus must be set to 'createAndGo'. |
| ansCrossConnect | 1.3.6.1.4.1.193.96.115.4.8 | |||
| ansCrossConnectTable | 1.3.6.1.4.1.193.96.115.4.8.1 | not-accessible | Entries in the ansCrossConnectTable represents ATM VP and VP cross-connections between access user ports and access service ports. | |
| ansCrossConnectEntry | 1.3.6.1.4.1.193.96.115.4.8.1.1 | not-accessible | ||
| INT ansCCAUPSystemNode | 1.3.6.1.4.1.193.96.115.4.8.1.1.1 | INTEGER | not-accessible | Reference to the system node the access user port belongs to. |
| INT ansCCAUPSubrack | 1.3.6.1.4.1.193.96.115.4.8.1.1.2 | INTEGER | not-accessible | Reference to the subrack the access user port belongs to. |
| INT ansCCAUPPosition | 1.3.6.1.4.1.193.96.115.4.8.1.1.3 | INTEGER | not-accessible | Reference to user port's slot position within the subrack. |
| INT ansCCAUPIndex | 1.3.6.1.4.1.193.96.115.4.8.1.1.4 | INTEGER | not-accessible | Reference to user port's physical interface on the board. |
| INT ansCCAUPVPI | 1.3.6.1.4.1.193.96.115.4.8.1.1.5 | INTEGER | not-accessible | VPI value at the user port. |
| INT ansCCAUPVCI | 1.3.6.1.4.1.193.96.115.4.8.1.1.6 | INTEGER | not-accessible | VCI value at the user port. (100000 = undefined) Not applicable. |
| INT ansCCASPSubrack | 1.3.6.1.4.1.193.96.115.4.8.1.1.7 | INTEGER | read-only | Reference to the subrack the access service port belongs to. |
| INT ansCCASPPosition | 1.3.6.1.4.1.193.96.115.4.8.1.1.8 | INTEGER | read-only | Reference to access service port port's slot position within the subrack. |
| INT ansCCASPIndex | 1.3.6.1.4.1.193.96.115.4.8.1.1.9 | INTEGER | read-only | Reference to access service port's physical interface on the board. |
| INT ansCCASPVPI | 1.3.6.1.4.1.193.96.115.4.8.1.1.10 | INTEGER | read-only | VPI value at the access service port. |
| INT ansCCASPVCI | 1.3.6.1.4.1.193.96.115.4.8.1.1.11 | INTEGER | read-only | VCI value at the access service port. (100000 = undefined) Not applicable. |
| ANS ansCCType | 1.3.6.1.4.1.193.96.115.4.8.1.1.12 | AnsCCType | read-only | Indicates if the entry is a VC or VP cross-connection. |
| ANS ansCCServiceClass | 1.3.6.1.4.1.193.96.115.4.8.1.1.13 | AnsCCServiceClass | read-only | Indicates ATM bearer service type. cbr1: Highest priority constant bit-rate service, used for circuit emulated POTS. cbr2: Lower priority constant bit-rate service, used for video transmissions. ubr: Lowest priority service, used for datacom. |
| INT ansCCPcrAtoB | 1.3.6.1.4.1.193.96.115.4.8.1.1.14 | INTEGER | read-only | Bandwidth in cells per second for the cross-connection in the downstream direction. UBR connections may be given any positive cell rate. The -1 indicates unspecified value. |
| INT ansCCPcrBtoA | 1.3.6.1.4.1.193.96.115.4.8.1.1.15 | INTEGER | read-only | Bandwidth in cells per second for the cross-connection in the upstream direction. UBR connections may be given any positive cell rate. The -1 indicates unspecified value. |
| ANS ansCCSourceType | 1.3.6.1.4.1.193.96.115.4.8.1.1.16 | AnsCCSourceType | read-only | Indicates the type of service that is transported on top of the ATM layer. |
| INT ansCCServiceType | 1.3.6.1.4.1.193.96.115.4.8.1.1.17 | INTEGER | read-only | Indicates the type of connection CE, ATM or ETHERNET. |
| INT ansCCOperStatus | 1.3.6.1.4.1.193.96.115.4.8.1.1.18 | INTEGER | read-only | |
| DAT ansCCLastOperStatusChange | 1.3.6.1.4.1.193.96.115.4.8.1.1.19 | DateAndTime | read-only | The time this VP cross-connect entered its current operational state. |
| ANS ansCCAdminStatus | 1.3.6.1.4.1.193.96.115.4.8.1.1.20 | AnsCCAdminStatus | read-write | |
| ANS ansCCMulti | 1.3.6.1.4.1.193.96.115.4.8.1.1.21 | AnsCCMulti | read-only | Indicates if the cross- connection is part of a point-to-point or a point-to-multi point connection. |
| ROW ansCCRowStatus | 1.3.6.1.4.1.193.96.115.4.8.1.1.22 | RowStatus | read-write | Used to delete cross-connect. A cross-connection is removed by seting the attribute to 'destroy'. |
| ansApplData | 1.3.6.1.4.1.193.96.115.4.9 | |||
| ansApplDataTable | 1.3.6.1.4.1.193.96.115.4.9.1 | not-accessible | ||
| ansApplDataEntry | 1.3.6.1.4.1.193.96.115.4.9.1.1 | not-accessible | ||
| INT ansApplDataSystemNode | 1.3.6.1.4.1.193.96.115.4.9.1.1.1 | INTEGER | read-only | Reference to the system node the access user port belongs to. |
| INT ansApplDataSubrack | 1.3.6.1.4.1.193.96.115.4.9.1.1.2 | INTEGER | read-only | Reference to the subrack the access user port belongs to. |
| INT ansApplDataPosition | 1.3.6.1.4.1.193.96.115.4.9.1.1.3 | INTEGER | read-only | Reference to user port's slot position within the subrack. |
| INT ansApplDataIndex | 1.3.6.1.4.1.193.96.115.4.9.1.1.4 | INTEGER | read-only | Reference to user port's physical interface on the board. |
| INT ansApplDataVPI | 1.3.6.1.4.1.193.96.115.4.9.1.1.5 | INTEGER | read-only | VPI value at the user port. |
| INT ansApplDataVCI | 1.3.6.1.4.1.193.96.115.4.9.1.1.6 | INTEGER | read-only | VCI value at the user port. |
| INT ansApplDataOpState | 1.3.6.1.4.1.193.96.115.4.9.1.1.7 | INTEGER | read-only | |
| INT ansApplDataAdminState | 1.3.6.1.4.1.193.96.115.4.9.1.1.8 | INTEGER | read-write | |
| INT ansApplDataServiceParams | 1.3.6.1.4.1.193.96.115.4.9.1.1.9 | INTEGER | read-only | |
| ansAal1Pars | 1.3.6.1.4.1.193.96.115.4.10 | |||
| ansAal1ParsTable | 1.3.6.1.4.1.193.96.115.4.10.1 | not-accessible | ||
| ansAal1ParsEntry | 1.3.6.1.4.1.193.96.115.4.10.1.1 | not-accessible | ||
| STR ansAal1ParsTimeSlot | 1.3.6.1.4.1.193.96.115.4.10.1.1.1 | DisplayString | read-only | The TS list has the format: [int1,int2,...]. not_used (unstructured) |
| INT ansAal1ParsType | 1.3.6.1.4.1.193.96.115.4.10.1.1.2 | INTEGER | read-only | |
| INT ansAal1ParsFillLevel | 1.3.6.1.4.1.193.96.115.4.10.1.1.3 | INTEGER | read-only | (-1) undefined |
| INT ansAal1ParsCdvt | 1.3.6.1.4.1.193.96.115.4.10.1.1.4 | INTEGER | read-write | (-1) undefined |
| INT ansAal1ParsMaxBuffSize | 1.3.6.1.4.1.193.96.115.4.10.1.1.5 | INTEGER | read-write | (-1) undefined |
| INT ansAal1ParsTcMode | 1.3.6.1.4.1.193.96.115.4.10.1.1.6 | INTEGER | read-only | |
| INT ansAal1ParsTcType | 1.3.6.1.4.1.193.96.115.4.10.1.1.7 | INTEGER | read-only | |
| INT ansAal1ParsTcBtoA | 1.3.6.1.4.1.193.96.115.4.10.1.1.8 | INTEGER | read-only | (-1) undefined |
| INT ansAal1ParsTcAtoB | 1.3.6.1.4.1.193.96.115.4.10.1.1.9 | INTEGER | read-only | (-1) undefined |
| ansEthPars | 1.3.6.1.4.1.193.96.115.4.11 | |||
| ansEthParsTable | 1.3.6.1.4.1.193.96.115.4.11.1 | not-accessible | ||
| ansEthParsEntry | 1.3.6.1.4.1.193.96.115.4.11.1.1 | not-accessible | ||
| INT ansEthParsPcrShaping | 1.3.6.1.4.1.193.96.115.4.11.1.1.1 | INTEGER | read-only | (-1) unspecified. |
| ethernetPort | 1.3.6.1.4.1.193.96.115.4.12 | |||
| ethernetPortTable | 1.3.6.1.4.1.193.96.115.4.12.1 | not-accessible | Entries in the ethernetPortTable represents extension records of the ethernet ports in the ansAccessUserPortTable. | |
| ethernetPortEntry | 1.3.6.1.4.1.193.96.115.4.12.1.1 | not-accessible | ||
| INT ethernetPortFcsEncapsulation | 1.3.6.1.4.1.193.96.115.4.12.1.1.1 | INTEGER | read-write | Turn the sending off FCS checksum on or off. |
| INT ethernetPortMuxOrEncapsulation | 1.3.6.1.4.1.193.96.115.4.12.1.1.2 | INTEGER | read-write | Reference to transfer of ethernet frames. |
| IP ethernetPortIpAddress | 1.3.6.1.4.1.193.96.115.4.12.1.1.3 | IpAddress | read-only | IP adress of the NT when attribute ethernetPortMuxOrEncapsulation is set to pppVc or pppLlc |
| INT ethernetPortType | 1.3.6.1.4.1.193.96.115.4.12.1.1.4 | INTEGER | read-only | Ethernet Type |
| INT ethernetPortOperatingMode | 1.3.6.1.4.1.193.96.115.4.12.1.1.5 | INTEGER | read-write | Ethernet Type |
| pdhPort | 1.3.6.1.4.1.193.96.115.4.13 | |||
| pdhPortTable | 1.3.6.1.4.1.193.96.115.4.13.1 | not-accessible | PDH Port Table | |
| pdhPortEntry | 1.3.6.1.4.1.193.96.115.4.13.1.1 | not-accessible | This entity represents a PDH port for circuit emulation. | |
| INT pdhPortPort | 1.3.6.1.4.1.193.96.115.4.13.1.1.1 | INTEGER | read-only | Port at AT and CE board |
| STR pdhPortTsUsed | 1.3.6.1.4.1.193.96.115.4.13.1.1.2 | DisplayString | read-only | Timeslot used |
| INT pdhPortClockMode | 1.3.6.1.4.1.193.96.115.4.13.1.1.3 | INTEGER | read-write | ... |
| INT pdhPortHaulMode | 1.3.6.1.4.1.193.96.115.4.13.1.1.4 | INTEGER | read-write | ... |
| INT pdhPortLineCode | 1.3.6.1.4.1.193.96.115.4.13.1.1.5 | INTEGER | read-write | hdb3 valid for ansAccessUser/ServicePortType = e1 ami valid for ansAccessUser/ServicePortType = ds1 b8zs valid for ansAccessUser/ServicePortType = ds1 |
| INT pdhPortLoopback | 1.3.6.1.4.1.193.96.115.4.13.1.1.6 | INTEGER | read-write | ... |
| INT pdhPortCas | 1.3.6.1.4.1.193.96.115.4.13.1.1.7 | INTEGER | read-write | ... |
| INT pdhPortFrameFormat | 1.3.6.1.4.1.193.96.115.4.13.1.1.8 | INTEGER | read-write | ... |
| INT pdhPortServiceType | 1.3.6.1.4.1.193.96.115.4.13.1.1.9 | INTEGER | read-write | ... |
| terminalId | 1.3.6.1.4.1.193.96.115.4.14 | |||
| ansTerminalIdTable | 1.3.6.1.4.1.193.96.115.4.14.1 | not-accessible | Entries in the ansTerminalIdTable represent the system node, subrack and position of ATs; These pieces of information can be used as an index into terminal specific tables to obtain complete information | |
| ansTerminalIdEntry | 1.3.6.1.4.1.193.96.115.4.14.1.1 | not-accessible | ||
| STR ansTerminalIdIdent | 1.3.6.1.4.1.193.96.115.4.14.1.1.1 | DisplayString | read-only | An index that uniquely identifies an AT |
| INT ansTerminalIdSystemNode | 1.3.6.1.4.1.193.96.115.4.14.1.1.2 | INTEGER | read-only | Reference to the system node the AT belongs to |
| INT ansTerminalIdSubrack | 1.3.6.1.4.1.193.96.115.4.14.1.1.3 | INTEGER | read-only | Reference to the subrack the AT belongs to |
| INT ansTerminalIdPosition | 1.3.6.1.4.1.193.96.115.4.14.1.1.4 | INTEGER | read-only | Reference to the slot the AT belongs to |
RFC description
Ericsson ADSL access network service MIB for managing access user ports, ATM formats, and service configurations.
Start monitoring Advanced Network Systems (ANS CO+RE) broadband access nodes (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.