ZTE-AN-PPPOE-TEST-MIB :: zxAnPppoeTestIfClientIpAddr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZTE-AN-PPPOE-TEST-MIB › zxAnPppoeTestIfClientIpAddr

zxAnPppoeTestIfClientIpAddr

Module: ZTE-AN-PPPOE-TEST-MIB

OID (symbolic): ZTE-AN-PPPOE-TEST-MIB::zxAnPppoeTestIfClientIpAddr

OID (numeric): 1.3.6.1.4.1.3902.1082.70.56.2.3.1.7

Node type: OBJECT-TYPE

Type: InetAddress

Access: read-only

Description: The IP address that is distributed by BAS.

What is zxAnPppoeTestIfClientIpAddr?

This read-only object reports the IP address that was distributed to the test client by the BAS during a successful PPPoE test. Admins check this to confirm the BAS is actually handing out valid addresses through this PPPoE path, useful for validating IP pool configuration end-to-end. A returned address from the expected subscriber IP pool confirms the BAS correctly assigned an address during the test.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.70.56.2.3.1.7
snmpwalk -v2c -c public <target> ZTE-AN-PPPOE-TEST-MIB::zxAnPppoeTestIfClientIpAddr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.70.56.2.3.1.7.1
snmpget -v2c -c public <target> ZTE-AN-PPPOE-TEST-MIB::zxAnPppoeTestIfClientIpAddr.1

Start monitoring ZTE access node (DSLAM/OLT broadband access platform) (PPPoE session-establishment diagnostic test-result status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-PPPOE-TEST-MIB::zxAnPppoeTestIfClientIpAddr OID value, configure state conditions and alerts, and monitor any ZTE access node (DSLAM/OLT broadband access platform) (PPPoE session-establishment diagnostic test-result status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteDPI-MIB
1.3.6.1.4.1.3902.1082zxAccessNodeZTE-AN-SMI
1.3.6.1.4.1.3902.1082.70zxAnServiceSecurityZTE-AN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1082.70.56zxAnPppoeTestMibZTE-AN-PPPOE-TEST-MIB
1.3.6.1.4.1.3902.1082.70.56.2zxAnPppoeTestObjectsZTE-AN-PPPOE-TEST-MIB
1.3.6.1.4.1.3902.1082.70.56.2.3zxAnPppoeTestIfStatusTableZTE-AN-PPPOE-TEST-MIB
1.3.6.1.4.1.3902.1082.70.56.2.3.1zxAnPppoeTestIfStatusEntryZTE-AN-PPPOE-TEST-MIB
1.3.6.1.4.1.3902.1082.70.56.2.3.1.7zxAnPppoeTestIfClientIpAddrZTE-AN-PPPOE-TEST-MIB