ZTE-AN-OPTICAL-MODULE-PERF-MIB :: zxAnOpticalC15MTxPower

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsZTE-AN-OPTICAL-MODULE-PERF-MIBzxAnOpticalC15MTxPower

zxAnOpticalC15MTxPower

Module: ZTE-AN-OPTICAL-MODULE-PERF-MIB

OID (symbolic): ZTE-AN-OPTICAL-MODULE-PERF-MIB::zxAnOpticalC15MTxPower

OID (numeric): 1.3.6.1.4.1.3902.1082.30.45.2.3.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The optical module transmitted power value in current 15-minute interval.

What is zxAnOpticalC15MTxPower?

The optical module's transmit power for the current, still-accumulating 15-minute interval, in thousandths of a dBm (e.g. a raw value of -1000 means -1.000 dBm); watch this alongside zxAnOpticalC15MRxPower to catch a laser degrading before the link actually drops.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.30.45.2.3.1.2
snmpwalk -v2c -c public <target> ZTE-AN-OPTICAL-MODULE-PERF-MIB::zxAnOpticalC15MTxPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.30.45.2.3.1.2.1
snmpget -v2c -c public <target> ZTE-AN-OPTICAL-MODULE-PERF-MIB::zxAnOpticalC15MTxPower.1

Start monitoring ZTE access-network (AN) equipment, OLT/ONU platforms with pluggable optical modules (historical optical-power/bias-current/temperature status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-OPTICAL-MODULE-PERF-MIB::zxAnOpticalC15MTxPower OID value, configure state conditions and alerts, and monitor any ZTE access-network (AN) equipment, OLT/ONU platforms with pluggable optical modules (historical optical-power/bias-current/temperature status) from a single console.

How to Use in IPNetwork Monitor

Select a ZTE access-network (AN) equipment, OLT/ONU platforms with pluggable optical module (historical optical-power/bias-current/temperature status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type zxAnOpticalC15MTxPower into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The optical module transmitted power value in current 15-minute interval. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteUAS-MIB
1.3.6.1.4.1.3902.1082zxAccessNodeZTE-AN-SMI
1.3.6.1.4.1.3902.1082.30zxAnInterfaceZTE-AN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1082.30.45zxAnOpticalModulePerfMibZTE-AN-OPTICAL-MODULE-PERF-MIB
1.3.6.1.4.1.3902.1082.30.45.2zxAnOpticalModulePerfObjectsZTE-AN-OPTICAL-MODULE-PERF-MIB
1.3.6.1.4.1.3902.1082.30.45.2.3zxAnOpticalCurr15MinPerfTableZTE-AN-OPTICAL-MODULE-PERF-MIB
1.3.6.1.4.1.3902.1082.30.45.2.3.1zxAnOpticalCurr15MinPerfEntryZTE-AN-OPTICAL-MODULE-PERF-MIB
1.3.6.1.4.1.3902.1082.30.45.2.3.1.2zxAnOpticalC15MTxPowerZTE-AN-OPTICAL-MODULE-PERF-MIB