All MIBs › ZTE-AN-ENVMON-MIB › zxAnFanTrayAutoSwitchByCardUp
zxAnFanTrayAutoSwitchByCardUp
Module: ZTE-AN-ENVMON-MIB
OID (symbolic): ZTE-AN-ENVMON-MIB::zxAnFanTrayAutoSwitchByCardUp
OID (numeric): 1.3.6.1.4.1.3902.1082.10.10.2.4.10.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Enable/disable fan auto switch with card installation. If it is enabled, the fan under the card should be switched to running status when the card is installed. Otherwise, the fan should be shutdown.
What is zxAnFanTrayAutoSwitchByCardUp?
Enables or disables automatically starting the fans under a slot as soon as a card is installed there, and shutting them down otherwise. Leaving this disabled means fan operation is controlled by the tray's own settings rather than reacting to individual card installs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.10.10.2.4.10.1.2 snmpwalk -v2c -c public <target> ZTE-AN-ENVMON-MIB::zxAnFanTrayAutoSwitchByCardUp
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.10.10.2.4.10.1.2.1 snmpget -v2c -c public <target> ZTE-AN-ENVMON-MIB::zxAnFanTrayAutoSwitchByCardUp.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3902.1082.10.10.2.4.10.1.2.1 i <value>
Start monitoring ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-ENVMON-MIB::zxAnFanTrayAutoSwitchByCardUp OID value, configure state conditions and alerts, and monitor any ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3902 | zte | DPI-MIB |
| 1.3.6.1.4.1.3902.1082 | zxAccessNode | ZTE-AN-SMI |
| 1.3.6.1.4.1.3902.1082.10 | zxAnEquipment | ZTE-AN-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3902.1082.10.10 | zxAnEnvMonMib | ZTE-AN-ENVMON-MIB |
| 1.3.6.1.4.1.3902.1082.10.10.2 | zxAnEnvMonObjects | ZTE-AN-ENVMON-MIB |
| 1.3.6.1.4.1.3902.1082.10.10.2.4 | zxAnEnvFanObjects | ZTE-AN-ENVMON-MIB |
| 1.3.6.1.4.1.3902.1082.10.10.2.4.10 | zxAnEnvFanTrayTable | ZTE-AN-ENVMON-MIB |
| 1.3.6.1.4.1.3902.1082.10.10.2.4.10.1 | zxAnEnvFanTrayEntry | ZTE-AN-ENVMON-MIB |
| 1.3.6.1.4.1.3902.1082.10.10.2.4.10.1.2 | zxAnFanTrayAutoSwitchByCardUp | ZTE-AN-ENVMON-MIB |