zxAnEnvEnergySavingLevel

Module: ZTE-AN-ENVMON-MIB

OID (symbolic): ZTE-AN-ENVMON-MIB::zxAnEnvEnergySavingLevel

OID (numeric): 1.3.6.1.4.1.3902.1082.10.10.2.3.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: level1(1): Level 1 means that the energy saving module action will be taken automatically while the following conditions are detected: 1. There is no card plugged in the slot or the card plugged in the slot has been power off. 2. The actual card type is not same as the configured card type. level2(2): Level 2 means that the energy saving module action will be taken automatically while the following conditions are detected: 1. There is no card plugged in the slot or the card plugged in the slot has been power off. 2. The actual card type is not same as the configured card type. 3. There is no ONU which is configured on the card or on the port. level3(3): Level 3 means that the energy saving module action will be taken automatically while the following conditions are detected: 1. There is no card plugged in the slot or the card plugged in the slot has been power off. 2. The actual card type is not same as the configured card type. 3. There is no ONU which is configured on the card or on the port. 4. If all the uplink ports down, all the cards except the uplink card will be power off.

What is zxAnEnvEnergySavingLevel?

Selects how aggressively the equipment automatically powers down unused resources: level1 shuts down empty or mismatched slots, level2 additionally shuts down ports with no ONU configured, and level3 goes further and powers off all non-uplink cards if every uplink port is down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.10.10.2.3.1.8
snmpwalk -v2c -c public <target> ZTE-AN-ENVMON-MIB::zxAnEnvEnergySavingLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.10.10.2.3.1.8.1
snmpget -v2c -c public <target> ZTE-AN-ENVMON-MIB::zxAnEnvEnergySavingLevel.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3902.1082.10.10.2.3.1.8.1 i <value>

Start monitoring ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-ENVMON-MIB::zxAnEnvEnergySavingLevel OID value, configure state conditions and alerts, and monitor any ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteDPI-MIB
1.3.6.1.4.1.3902.1082zxAccessNodeZTE-AN-SMI
1.3.6.1.4.1.3902.1082.10zxAnEquipmentZTE-AN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1082.10.10zxAnEnvMonMibZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2zxAnEnvMonObjectsZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.3zxAnEnvPowerSupplyObjectsZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.3.1zxAnPowerSupplyGlobalObjectsZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.3.1.8zxAnEnvEnergySavingLevelZTE-AN-ENVMON-MIB