ZTE-AN-ENVMON-MIB :: zxAnCardEnvHis15MinTemp

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZTE-AN-ENVMON-MIB › zxAnCardEnvHis15MinTemp

zxAnCardEnvHis15MinTemp

Module: ZTE-AN-ENVMON-MIB

OID (symbolic): ZTE-AN-ENVMON-MIB::zxAnCardEnvHis15MinTemp

OID (numeric): 1.3.6.1.4.1.3902.1082.10.10.2.1.7.1.3

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The 15 minutes interval average temperature of card.

What is zxAnCardEnvHis15MinTemp?

Records the average card temperature measured over one 15-minute historical interval, part of a rolling history of up to 96 intervals, covering 24 hours, used to spot temperature trends rather than relying only on the current live reading.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.10.10.2.1.7.1.3
snmpwalk -v2c -c public <target> ZTE-AN-ENVMON-MIB::zxAnCardEnvHis15MinTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.10.10.2.1.7.1.3.1
snmpget -v2c -c public <target> ZTE-AN-ENVMON-MIB::zxAnCardEnvHis15MinTemp.1

Start monitoring ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-ENVMON-MIB::zxAnCardEnvHis15MinTemp OID value, configure state conditions and alerts, and monitor any ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) from a single console.

How to Use in IPNetwork Monitor

Select a ZTE Access Node chassis (temperature/power-supply-voltage/fan-speed threshold status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type zxAnCardEnvHis15MinTemp into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The 15 minutes interval average temperature of card. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteDPI-MIB
1.3.6.1.4.1.3902.1082zxAccessNodeZTE-AN-SMI
1.3.6.1.4.1.3902.1082.10zxAnEquipmentZTE-AN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1082.10.10zxAnEnvMonMibZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2zxAnEnvMonObjectsZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.1zxAnEnvParamObjectsZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.1.7zxAnCardEnvHis15MinPerfTableZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.1.7.1zxAnCardEnvHis15MinPerfEntryZTE-AN-ENVMON-MIB
1.3.6.1.4.1.3902.1082.10.10.2.1.7.1.3zxAnCardEnvHis15MinTempZTE-AN-ENVMON-MIB