MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZHNSYSTEM › sysTr69cServerParameterKey

sysTr69cServerParameterKey

Module: ZHNSYSTEM

OID (symbolic): ZHNSYSTEM::sysTr69cServerParameterKey

OID (numeric): 1.3.6.1.4.1.5504.2.5.2.1.17.2.7

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: ParameterKey provides the ACS a reliable and extensible means to track changes made by the ACS. The value of ParameterKey MUST be equal to the value of the ParameterKey argument from the most recent successful SetParameterValues, AddObject, or DeleteObject method call from the ACS. The CPE MUST set ParameterKey to the value specified in the corresponding method arguments if and only if the method completes successfully and no fault response is generated. If a method call does not complete successfully implying that the changes requested in the method did not take effect, the value of ParameterKey MUST NOT be modified. The CPE MUST only modify the value of ParameterKey as a result of SetParameterValues, AddObject, DeleteObject, or due to a factory reset. On factory reset, the value of ParameterKey MUST be set to empty.

What is sysTr69cServerParameterKey?

Reports the ParameterKey value the ACS uses to confirm its last configuration change (via SetParameterValues, AddObject, or DeleteObject) was applied successfully; it's cleared to empty on a factory reset and otherwise only changes after a successful ACS-initiated change.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5504.2.5.2.1.17.2.7
snmpwalk -v2c -c public <target> ZHNSYSTEM::sysTr69cServerParameterKey

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5504.2.5.2.1.17.2.7.1
snmpget -v2c -c public <target> ZHNSYSTEM::sysTr69cServerParameterKey.1

Start monitoring Zhone Technologies broadband access node, Zhone DSL/fiber gateway (device-identity/timing-sync-mode status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZHNSYSTEM::sysTr69cServerParameterKey OID value, configure state conditions and alerts, and monitor any Zhone Technologies broadband access node, Zhone DSL/fiber gateway (device-identity/timing-sync-mode status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5504ZhoneBITSTORM-HP-160-MIB
1.3.6.1.4.1.5504.2zhoneProductZhone
1.3.6.1.4.1.5504.2.5zhoneWtnZhone
Numeric OIDNameModule
1.3.6.1.4.1.5504.2.5.2zhnSystemZHNSYSTEM
1.3.6.1.4.1.5504.2.5.2.1zhnSystemObjectsZHNSYSTEM
1.3.6.1.4.1.5504.2.5.2.1.17zhnSystemTr69cObjectsZHNSYSTEM
1.3.6.1.4.1.5504.2.5.2.1.17.2sysTr69cServerObjectsZHNSYSTEM
1.3.6.1.4.1.5504.2.5.2.1.17.2.7sysTr69cServerParameterKeyZHNSYSTEM