All MIBs › ZHNLAYER2BRIDGING › vlanTLSMode
vlanTLSMode
Module: ZHNLAYER2BRIDGING
OID (symbolic): ZHNLAYER2BRIDGING::vlanTLSMode
OID (numeric): 1.3.6.1.4.1.5504.2.5.42.1.13.1
Node type: OBJECT-TYPE
Type: VlanTLSMode
Access: read-write
Description: This object implements transparent LAN service (TLS) by using a S-Tag (Service Provider tag) to tunnel the customer traffic over a service provider network. The CPE can operate in normal or S-Tag mode. In normal mode, CPE device operates according to the IEEE 802.1Q or 802.1D specifications. In S-TAG mode, the CPE device operates as follows: 1) The CPE's TPID (tag protocol ID) must be provisioned. 2) A S-Tag frame consists of a VLAN ID and a TPID that matches the CPE's provisioned TPID. 3) When the CPE adds a S-TAG, the S-Tag's VLAN ID will be taken from the CPE's default PVID and the TPID will be taken from the CPE's provisioned TPID. 4) The CPE device supports a TLS-Bridge. The ports on this bridge can be either S-TAG or TLS members. S-Tag port - The input frames from the service provider port may or may not have a S-TAG. The CPE will compare the tagged frame's TPID against the provisioned S-TAG TPID. If there is a match, the CPE will bridge the frame based on the VLAN ID in the S-Tag. If there is not a match, the frame is forwarded to the CPU. TLS port - The CPE will add a S-Tag to all input frames from this port regardless of whether the frames have a 802.1Q tag or not. The CPE will bridge the frames based on the VLAN ID in the S-Tag. Only a VLAN-tagged or untagged frames are expected from the ingress of a TLS (customer) port.
What is vlanTLSMode?
Selects whether the CPE runs in normal 802.1Q/802.1D mode or in S-TAG (Transparent LAN Service) mode, where a provisioned TPID is used to wrap customer traffic in a service-provider S-Tag for tunneling across a carrier network; an admin sets sTag mode when the device must support a TLS-Bridge with S-TAG or TLS member ports.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5504.2.5.42.1.13.1 snmpwalk -v2c -c public <target> ZHNLAYER2BRIDGING::vlanTLSMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5504.2.5.42.1.13.1.1 snmpget -v2c -c public <target> ZHNLAYER2BRIDGING::vlanTLSMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5504.2.5.42.1.13.1.1 s <value>
Start monitoring Zhone Technologies VoIP CPE devices (bridge-table capacity/port-membership/VLAN-filter config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZHNLAYER2BRIDGING::vlanTLSMode OID value, configure state conditions and alerts, and monitor any Zhone Technologies VoIP CPE devices (bridge-table capacity/port-membership/VLAN-filter config status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5504 | Zhone | BITSTORM-HP-160-MIB |
| 1.3.6.1.4.1.5504.2 | zhoneProduct | Zhone |
| 1.3.6.1.4.1.5504.2.5 | zhoneWtn | Zhone |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5504.2.5.42 | zhnLayer2Bridging | ZHNLAYER2BRIDGING |
| 1.3.6.1.4.1.5504.2.5.42.1 | layer2BridgingObjects | ZHNLAYER2BRIDGING |
| 1.3.6.1.4.1.5504.2.5.42.1.13 | layer2BridgingGlobalObjects | ZHNLAYER2BRIDGING |
| 1.3.6.1.4.1.5504.2.5.42.1.13.1 | vlanTLSMode | ZHNLAYER2BRIDGING |