XF-RADIOLINK-PTP-RADIO-MIB :: xfRfSelectedMinOutputPower

MIB Reference — IPNetwork Monitor

All MIBsXF-RADIOLINK-PTP-RADIO-MIBxfRfSelectedMinOutputPower

xfRfSelectedMinOutputPower

Module: XF-RADIOLINK-PTP-RADIO-MIB

OID (symbolic): XF-RADIOLINK-PTP-RADIO-MIB::xfRfSelectedMinOutputPower

OID (numeric): 1.3.6.1.4.1.193.81.3.4.3.1.8.1.1

Node type: OBJECT-TYPE

Type: RfOutputPower

Access: read-write

Description:

Minimum output power in dBm (selected by operator). Default value: 10 dBm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.81.3.4.3.1.8.1.1
snmpwalk -v2c -c public <target> XF-RADIOLINK-PTP-RADIO-MIB::xfRfSelectedMinOutputPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.81.3.4.3.1.8.1.1.1
snmpget -v2c -c public <target> XF-RADIOLINK-PTP-RADIO-MIB::xfRfSelectedMinOutputPower.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.193.81.3.4.3.1.8.1.1.1 s <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.81miniLinkXFXF-TOP-MIB
1.3.6.1.4.1.193.81.3xfMediaSpecificXF-TOP-MIB
1.3.6.1.4.1.193.81.3.4xfRadioLinkXF-TOP-MIB
1.3.6.1.4.1.193.81.3.4.3xfRadioLinkPtpRadioMIBXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1xfRadioLinkPtpRadioObjectsXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1.8xfRfIfPowerTableXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1.8.1xfRfIfPowerEntryXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1.8.1.1xfRfSelectedMinOutputPowerXF-RADIOLINK-PTP-RADIO-MIB