XF-RADIOLINK-PTP-RADIO-MIB :: xfRAUAlarmStatus

MIB Reference — IPNetwork Monitor · Updated September 26, 2026

All MIBs › XF-RADIOLINK-PTP-RADIO-MIB › xfRAUAlarmStatus

xfRAUAlarmStatus

Module: XF-RADIOLINK-PTP-RADIO-MIB

OID (symbolic): XF-RADIOLINK-PTP-RADIO-MIB::xfRAUAlarmStatus

OID (numeric): 1.3.6.1.4.1.193.81.3.4.3.1.1.1.1

Node type: OBJECT-TYPE

Type: Bits

Access: read-only

Description: This object shows the alarm status of the radio unit. atpcCability - The terminal is configured for ATPC, but the radio does not support ATPC. This alarm is activated only if ATPC is turned on (any direction). sdcHwErrorMain - Received RF input signal level for Main path (of SDC TRX) has dropped below the threshold for the receiver. sdcHwErrorDiv - Received RF input signal level for Diversity path (of SDC TRX) has dropped below the threshold for the receiver. sdcDadeCalMismatch - A TRX is connected and its Serial Number doesn't match with the serial number stored into MO xfTRXSdcSerialNumber. insufficientResourceRauXpic - Connected RAU is missing capabilities for XPIC. companionRauMismatch - Connected RAU does not match with the companion one, either in 1+1 RLP or XPIC.

What is xfRAUAlarmStatus?

A read-only BITS field reporting radio-unit-level alarms such as atpcCapability (ATPC turned on but the radio doesn't support it), sdcHwErrorMain/Div (SDC receive path signal dropped below threshold), sdcDadeCalMismatch (connected TRX serial number doesn't match the stored calibration), insufficientResourceRauXpic (radio lacks XPIC capability), and companionRauMismatch (paired RAU in 1+1/XPIC doesn't match). An admin checks this bitmap first when a radio link is degraded, since it points to the specific hardware/configuration mismatch causing the problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.81.3.4.3.1.1.1.1
snmpwalk -v2c -c public <target> XF-RADIOLINK-PTP-RADIO-MIB::xfRAUAlarmStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.81.3.4.3.1.1.1.1.1
snmpget -v2c -c public <target> XF-RADIOLINK-PTP-RADIO-MIB::xfRAUAlarmStatus.1

Start monitoring Ericsson XF/MINI-LINK point-to-point microwave radio unit (TX-power/RX-signal-level status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the XF-RADIOLINK-PTP-RADIO-MIB::xfRAUAlarmStatus OID value, configure state conditions and alerts, and monitor any Ericsson XF/MINI-LINK point-to-point microwave radio unit (TX-power/RX-signal-level status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.81miniLinkXFXF-TOP-MIB
1.3.6.1.4.1.193.81.3xfMediaSpecificXF-TOP-MIB
1.3.6.1.4.1.193.81.3.4xfRadioLinkXF-TOP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.193.81.3.4.3xfRadioLinkPtpRadioMIBXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1xfRadioLinkPtpRadioObjectsXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1.1xfRAUTableXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1.1.1xfRAUEntryXF-RADIOLINK-PTP-RADIO-MIB
1.3.6.1.4.1.193.81.3.4.3.1.1.1.1xfRAUAlarmStatusXF-RADIOLINK-PTP-RADIO-MIB