Wellfleet-SWSMDS-MIB :: wfSmdsSwUsageStoreInterval

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-SWSMDS-MIB › wfSmdsSwUsageStoreInterval

wfSmdsSwUsageStoreInterval

Module: Wellfleet-SWSMDS-MIB

OID (symbolic): Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreInterval

OID (numeric): 1.3.6.1.4.1.18.3.5.9.7.9.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval.

What is wfSmdsSwUsageStoreInterval?

How often, in minutes (default 10), the billing process writes usage data from the wfSmdsSwUsage MIB out to the file system.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.7.9.8
snmpwalk -v2c -c public <target> Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.7.9.8.1
snmpget -v2c -c public <target> Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.9.7.9.8.1 i <value>

Start monitoring Wellfleet router, Bay Networks/Nortel WAN router (SMDS virtual-circuit provisioning/error-counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreInterval OID value, configure state conditions and alerts, and monitor any Wellfleet router, Bay Networks/Nortel WAN router (SMDS virtual-circuit provisioning/error-counter status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.9wfWanGroupWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.9.7wfSmdsSwGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.9.7.9wfSmdsSwUsageWellfleet-SWSMDS-MIB
1.3.6.1.4.1.18.3.5.9.7.9.8wfSmdsSwUsageStoreIntervalWellfleet-SWSMDS-MIB