Wellfleet-SWSMDS-MIB :: wfSmdsSwUsageStoreData

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-SWSMDS-MIB › wfSmdsSwUsageStoreData

wfSmdsSwUsageStoreData

Module: Wellfleet-SWSMDS-MIB

OID (symbolic): Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreData

OID (numeric): 1.3.6.1.4.1.18.3.5.9.7.9.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Setting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.

What is wfSmdsSwUsageStoreData?

Setting this to any non-zero value immediately triggers an update and write of billing usage data to disk; reset to zero afterward to re-arm it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.7.9.17
snmpwalk -v2c -c public <target> Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.7.9.17.1
snmpget -v2c -c public <target> Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.9.7.9.17.1 i <value>

Start monitoring Wellfleet router, Bay Networks/Nortel WAN router (SMDS virtual-circuit provisioning/error-counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-SWSMDS-MIB::wfSmdsSwUsageStoreData OID value, configure state conditions and alerts, and monitor any Wellfleet router, Bay Networks/Nortel WAN router (SMDS virtual-circuit provisioning/error-counter status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.9wfWanGroupWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.9.7wfSmdsSwGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.9.7.9wfSmdsSwUsageWellfleet-SWSMDS-MIB
1.3.6.1.4.1.18.3.5.9.7.9.17wfSmdsSwUsageStoreDataWellfleet-SWSMDS-MIB