Wellfleet-OSPF-MIB :: wfOspfNbrPriority

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-OSPF-MIB › wfOspfNbrPriority

wfOspfNbrPriority

Module: Wellfleet-OSPF-MIB

OID (symbolic): Wellfleet-OSPF-MIB::wfOspfNbrPriority

OID (numeric): 1.3.6.1.4.1.18.3.5.3.2.3.7.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: 'The priority of this neighbor in the designated router election algorithm. The value 0 signifies that the neighbor is not eligible to become the designated router on this particular network.' This is the user configurable/changeable neighbor's priority

What is wfOspfNbrPriority?

The configured priority value for this static neighbor in the Designated Router election, where 0 makes the neighbor ineligible for DR/BDR. This is the admin-set configuration value, distinct from wfOspfCurNbrPriority which reflects what the neighbor actually advertises in its live Hello packets.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.3.2.3.7.1.9
snmpwalk -v2c -c public <target> Wellfleet-OSPF-MIB::wfOspfNbrPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.3.2.3.7.1.9.1
snmpget -v2c -c public <target> Wellfleet-OSPF-MIB::wfOspfNbrPriority.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.3.2.3.7.1.9.1 i <value>

Start monitoring Wellfleet/Bay Networks routers (OSPF neighbor-adjacency/LSA-database status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-OSPF-MIB::wfOspfNbrPriority OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks routers (OSPF neighbor-adjacency/LSA-database status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3wfInternetWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2wfIpRoutingWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2.3wfOspfGroupWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2.3.7wfOspfNbrTableRFC7777-MIB
1.3.6.1.4.1.18.3.5.3.2.3.7.1wfOspfNbrEntryRFC7777-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.3.2.3.7.1.9wfOspfNbrPriorityWellfleet-OSPF-MIB