Wellfleet-OSPF-MIB :: wfOspfIfHelloInterval

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-OSPF-MIB › wfOspfIfHelloInterval

wfOspfIfHelloInterval

Module: Wellfleet-OSPF-MIB

OID (symbolic): Wellfleet-OSPF-MIB::wfOspfIfHelloInterval

OID (numeric): 1.3.6.1.4.1.18.3.5.3.2.3.5.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: 'The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for all routers attached to a common network.'

What is wfOspfIfHelloInterval?

Sets how often, in seconds, this interface sends OSPF Hello packets, defaulting to 10 seconds; every router on the same network segment must use the same value or they won't form an adjacency. Admins might shorten this on fast-converging networks or lengthen it (paired with a longer wfOspfIfRtrDeadInterval) on low-bandwidth links to cut Hello overhead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.3.2.3.5.1.11
snmpwalk -v2c -c public <target> Wellfleet-OSPF-MIB::wfOspfIfHelloInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.3.2.3.5.1.11.1
snmpget -v2c -c public <target> Wellfleet-OSPF-MIB::wfOspfIfHelloInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.3.2.3.5.1.11.1 i <value>

Start monitoring Wellfleet/Bay Networks routers (OSPF neighbor-adjacency/LSA-database status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-OSPF-MIB::wfOspfIfHelloInterval OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks routers (OSPF neighbor-adjacency/LSA-database status) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3wfInternetWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2wfIpRoutingWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2.3wfOspfGroupWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2.3.5wfOspfIfTableRFC7777-MIB
1.3.6.1.4.1.18.3.5.3.2.3.5.1wfOspfIfEntryRFC7777-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.3.2.3.5.1.11wfOspfIfHelloIntervalWellfleet-OSPF-MIB