WWP-LEOS-PORT-XCVR-MIB

MIB Reference — IPNetwork Monitor

All MIBsWWP-LEOS-PORT-XCVR-MIB

Organization: Ciena, Inc

Last Updated: 2011-07-06

Category: Ciena LEOS Carrier Ethernet

Description:

Monitors Ciena LEOS optical transceiver module parameters including Tx/Rx power, temperature, and voltage.

Imported Objects

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DisplayString
TruthValue

From WWP-SMI

wwpModulesOBJECT-IDENTITY
wwpModulesLeosOBJECT-IDENTITY

What Is WWP-LEOS-PORT-XCVR-MIB?

This Ciena/WWP LEOS proprietary MIB exposes digital diagnostic monitoring (DDM) data for pluggable optical transceiver modules (SFP/SFP+/XFP) installed in switch ports. It exposes hardware environmental telemetry: transmit and receive optical power levels, transceiver temperature, and supply voltage, along with associated alarm/warning thresholds. This is a direct hardware-health monitoring MIB, letting operators detect a degrading or failing optical transceiver, such as falling Rx power indicating a dirty or failing fiber link, or temperature exceeding safe limits, before it causes a link outage. It parallels the functionality of the standards-based SFF-8472 DDM specification and the concept behind the IETF ENTITY-SENSOR-MIB, though implemented as a WWP-LEOS proprietary table. It is deployed on Metro Ethernet switches using pluggable optics, especially in outdoor or environmentally variable installations. Engineers can download the WWP-LEOS-PORT-XCVR-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in WWP-LEOS-PORT-XCVR-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • transceiver Tx optical power
  • transceiver Rx optical power
  • transceiver temperature
  • transceiver supply voltage
  • power/temperature alarm thresholds

Supported Devices

  • Ciena/World Wide Packets Metro Ethernet switch (optical transceiver ports)

Monitoring Examples

No sample objects were provided for this module in the source data. In general, a transceiver DDM MIB of this kind exposes a per-port table of current Tx/Rx power, temperature, and voltage readings with alarm/warning thresholds, which an operator would poll to catch a transceiver whose Rx power has degraded below threshold, an early warning of a failing fiber connection.

OIDs
OID symbolicOID numericTypeAccessDescription
wwpLeosPortXcvrMIB1.3.6.1.4.1.6141.2.60.4Corrected Units changed watts to uW in descriptions.
wwpLeosPortXcvrMIBObjects1.3.6.1.4.1.6141.2.60.4.1
wwpLeosPortXcvr1.3.6.1.4.1.6141.2.60.4.1.1
wwpLeosPortXcvrTable1.3.6.1.4.1.6141.2.60.4.1.1.1not-accessibleThis table contains descriptions and settings for each of the physical transceiver devices.
wwpLeosPortXcvrEntry1.3.6.1.4.1.6141.2.60.4.1.1.1.1not-accessibleThe Transciever Device Entry.
INT wwpLeosPortXcvrId1.3.6.1.4.1.6141.2.60.4.1.1.1.1.1INTEGERread-onlyThe ID for the transceiver.
INT wwpLeosPortXcvrOperState1.3.6.1.4.1.6141.2.60.4.1.1.1.1.2INTEGERread-onlyThe operational state of the transceiver.
INT wwpLeosPortXcvrIdentiferType1.3.6.1.4.1.6141.2.60.4.1.1.1.1.3INTEGERread-onlyType for the transceiver.
INT wwpLeosPortXcvrExtIdentiferType1.3.6.1.4.1.6141.2.60.4.1.1.1.1.4INTEGERread-onlyExtended identifier type for this transceiver.
INT wwpLeosPortXcvrConnectorType1.3.6.1.4.1.6141.2.60.4.1.1.1.1.5INTEGERread-onlyType of connector. unknown(1), sc(2), fiberChannelStyle1(3), fiberChannelStyle2(4), bnc/tnc(5), coaxialHeader(6), fiberJack(7), lc(8), mt-rj(9), mu(10), sg(11), opticalPitTail(12), reserved(13..32), hssdc(33), copperPitTail(34), reserved(35..128), vendorSpecific(129..256).
INT wwpLeosPortXcvrType1.3.6.1.4.1.6141.2.60.4.1.1.1.1.6INTEGERread-onlyType of Transceiver.
STR wwpLeosPortXcvrVendorName1.3.6.1.4.1.6141.2.60.4.1.1.1.1.7DisplayStringread-onlyString containing this transceiver's vendor name.
OCT wwpLeosPortXcvrVendorOUI1.3.6.1.4.1.6141.2.60.4.1.1.1.1.8OCTET STRINGread-onlyString containing this transceiver's vendor OUI.
STR wwpLeosPortXcvrVendorPN1.3.6.1.4.1.6141.2.60.4.1.1.1.1.9DisplayStringread-onlyString containing this transceiver's vendor OUI.
STR wwpLeosPortXcvrRevNum1.3.6.1.4.1.6141.2.60.4.1.1.1.1.10DisplayStringread-onlyString containing this transceiver's part revision number.
STR wwpLeosPortXcvrSerialNum1.3.6.1.4.1.6141.2.60.4.1.1.1.1.11DisplayStringread-onlyString containing this transceiver's part serial number.
INT wwpLeosPortXcvrEncodingType1.3.6.1.4.1.6141.2.60.4.1.1.1.1.12INTEGERread-onlyIf wwpLeosPortXcvrIdentiferType is SFP, then the following values is defined for the encoding type: unspecified(1), 8B10B(2), 4b5b(3), NRZ(4), Manchester(5), SONET(6), reserved(7-256) If wwpLeosPortXcvrIdentiferType is XFP, then the following values is defined for the encoding type: Bit 7: 64B/66B (yes/no) Bit 6: 8B10B (yes/no) Bit 5: Sonet Scrambled (yes/no) Bit 4: NRZ (yes/no) Bit 3: RZ (yes/no) Bit 2: Tx Dither Support (yes/no) Bit 1: Reserved Bit 0: Reserved Multiple bits can be set at once in the case of XFP. For instance, to indicate support for NRZ(4) and Sonet scrambled (5), the user would see this object with the value of 16 + 32 = 48
STR wwpLeosPortXcvrMfgDate1.3.6.1.4.1.6141.2.60.4.1.1.1.1.13DisplayStringread-onlyThe transceiver's manufacture date in string.
INT wwpLeosPortXcvrComplianceVer1.3.6.1.4.1.6141.2.60.4.1.1.1.1.14INTEGERread-onlyThis represents the compliance version. Value 1 means digital diagnostic functionality not included or undefined Value 2 means includes functionality defined in Rev 9.0 SFF-8472 Value 3 means TBD Value 4 means TBD.
INT wwpLeosPortXcvrWaveLength1.3.6.1.4.1.6141.2.60.4.1.1.1.1.15INTEGERread-onlyThis represents the wavelength of the transceiver. Units are nano meter.
INT wwpLeosPortXcvrTemperature1.3.6.1.4.1.6141.2.60.4.1.1.1.1.16INTEGERread-onlyThis represents the temperature of the transceiver. Units are in degrees C
INT wwpLeosPortXcvrVcc1.3.6.1.4.1.6141.2.60.4.1.1.1.1.17INTEGERread-onlyThis represents the voltage of the transceiver.
INT wwpLeosPortXcvrBias1.3.6.1.4.1.6141.2.60.4.1.1.1.1.18INTEGERread-onlyThis represents the bias of the transceiver.
INT wwpLeosPortXcvrRxPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.19INTEGERread-onlyThis represents the measured receive power of the transceiver. Units are micro Watts.
INT wwpLeosPortXcvrTxState1.3.6.1.4.1.6141.2.60.4.1.1.1.1.20INTEGERread-onlyIndicates whether this transceiver is currently set to transmit.
INT wwpLeosPortXcvrTxFaultStatus1.3.6.1.4.1.6141.2.60.4.1.1.1.1.21INTEGERread-onlyIndicates the fault status of this transceiver.
INT wwpLeosPortXcvrRxRateStatus1.3.6.1.4.1.6141.2.60.4.1.1.1.1.22INTEGERread-onlyIndicates the Rx rate status of this transceiver.
INT wwpLeosPortXcvr9by125um1.3.6.1.4.1.6141.2.60.4.1.1.1.1.23INTEGERread-onlyIndicates the link length for 9/125um fiber.
INT wwpLeosPortXcvr50by125um1.3.6.1.4.1.6141.2.60.4.1.1.1.1.24INTEGERread-onlyIndicates the link length for 50/125um fiber.
INT wwpLeosPortXcvr62dot5by125um1.3.6.1.4.1.6141.2.60.4.1.1.1.1.25INTEGERread-onlyIndicates the link length for 62.5/125um fiber.
INT wwpLeosPortXcvrCu1.3.6.1.4.1.6141.2.60.4.1.1.1.1.26INTEGERread-onlyIndicates the link length for copper.
INT wwpLeosPortXcvrTxOutputPw1.3.6.1.4.1.6141.2.60.4.1.1.1.1.27INTEGERread-onlyIndicates the Tx Output power for the transceiver. Units are micro Watts.
T/F wwpLeosPortXcvrLosState1.3.6.1.4.1.6141.2.60.4.1.1.1.1.28TruthValueread-onlyIndicates the Loss Of Signal State for the optical transceiver. Ports without optical transceiver will always report 'false'.
T/F wwpLeosPortXcvrDiagSupported1.3.6.1.4.1.6141.2.60.4.1.1.1.1.29TruthValueread-onlyIndicates if diagnostics are supported on this transceiver.
T/F wwpLeosPortXcvrEnhDiagAlarmSupported1.3.6.1.4.1.6141.2.60.4.1.1.1.1.30TruthValueread-onlyIndicates if enhanced diagnostics alarms / warnings implemented.
T/F wwpLeosPortXcvrEnhDiagSoftTxDisableSupported1.3.6.1.4.1.6141.2.60.4.1.1.1.1.31TruthValueread-onlyIndicates if enhanced diagnostics soft Tx disable control is implemented.
T/F wwpLeosPortXcvrEnhDiagSoftTxFaultSupported1.3.6.1.4.1.6141.2.60.4.1.1.1.1.32TruthValueread-onlyIndicates if enhanced diagnostics soft Tx fault monitoring is implemented.
T/F wwpLeosPortXcvrEnhDiagRxLosSupported1.3.6.1.4.1.6141.2.60.4.1.1.1.1.33TruthValueread-onlyIndicates if enhanced diagnostics Rx LOS monitoring is implemented.
I32 wwpLeosPortXcvrHighTempAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.34Integer32read-onlyIndicates the higher threshold for temperature alarm.
I32 wwpLeosPortXcvrLowTempAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.35Integer32read-onlyIndicates the lower threshold for temperature alarm.
I32 wwpLeosPortXcvrHighVccAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.36Integer32read-onlyIndicates the higher threshold for voltage alarm.
I32 wwpLeosPortXcvrLowVccAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.37Integer32read-onlyIndicates the lower threshold for voltage alarm.
I32 wwpLeosPortXcvrHighBiasAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.38Integer32read-onlyIndicates the higher threshold for bias alarm.
I32 wwpLeosPortXcvrLowBiasAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.39Integer32read-onlyIndicates the lower threshold for bias alarm.
I32 wwpLeosPortXcvrHighTxPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.40Integer32read-onlyIndicates the higher threshold for Tx power alarm. Units are micro watts
I32 wwpLeosPortXcvrLowTxPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.41Integer32read-onlyIndicates the lower threshold for Tx power alarm. Units are micro watts.
I32 wwpLeosPortXcvrHighRxPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.42Integer32read-onlyIndicates the higher threshold for Rx power alarm. Units are micro watts.
I32 wwpLeosPortXcvrLowRxPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.43Integer32read-onlyIndicates the lower threshold for Rx power alarm. Units are micro watts.
T/F wwpLeosPortXcvrEnhDiagRateSelectSupported1.3.6.1.4.1.6141.2.60.4.1.1.1.1.44TruthValueread-onlyIndicates if enhanced diagnostics soft rate select control is implemented.
INT wwpLeosPortXcvrAdminState1.3.6.1.4.1.6141.2.60.4.1.1.1.1.45INTEGERread-writeThe admin state of the transceiver.
INT wwpLeosPortXcvrXfpMinBitRate1.3.6.1.4.1.6141.2.60.4.1.1.1.1.70INTEGERread-onlyThis represents the minimum bit rate.
INT wwpLeosPortXcvrXfpMaxBitRate1.3.6.1.4.1.6141.2.60.4.1.1.1.1.71INTEGERread-onlyThis represents the maximum bit rate.
INT wwpLeosPortXcvrXfpLinkLenSmf1km1.3.6.1.4.1.6141.2.60.4.1.1.1.1.72INTEGERread-onlyThis represents the length (SMF fiber) 1km.
INT wwpLeosPortXcvrXfpLinkLenE50u2m1.3.6.1.4.1.6141.2.60.4.1.1.1.1.73INTEGERread-onlyThis represents the length (ext. BW MMF) 2m.
INT wwpLeosPortXcvrXfpLinkLen50u1m1.3.6.1.4.1.6141.2.60.4.1.1.1.1.74INTEGERread-onlyThis represents the length (50um) 1m.
INT wwpLeosPortXcvrXfpLinkLen62dot5u1m1.3.6.1.4.1.6141.2.60.4.1.1.1.1.75INTEGERread-onlyThis represents the length (62.5um) 1m.
INT wwpLeosPortXcvrXfpLinkLenCopper1m1.3.6.1.4.1.6141.2.60.4.1.1.1.1.76INTEGERread-onlyThis represents the length (copper) 1m.
INT wwpLeosPortXcvrXfpDevTech1.3.6.1.4.1.6141.2.60.4.1.1.1.1.77INTEGERread-onlyThis represents the device technology.
INT wwpLeosPortXcvrXfpTransmitterTech1.3.6.1.4.1.6141.2.60.4.1.1.1.1.78INTEGERread-onlyThis represents the device transmitter technology: Bit 3: Wavelength Control (active/none) Bit 2: Transmitter Cooling (cooled/uncooled) Bit 1: Detector Type (apd/pin) Bit 0: Transmitter Tuning (Tunable/non-Tunable)
INT wwpLeosPortXcvrXfpCdrSupport1.3.6.1.4.1.6141.2.60.4.1.1.1.1.79INTEGERread-onlyThis represents the CDR support: Bit 7: 9.95 Gb/s (yes/no) Bit 6: 10.3 Gb/s (yes/no) Bit 5: 10.5 Gb/s (yes/no) Bit 4: 10.7 Gb/s (yes/no) Bit 3: 11.1 Gb/s (yes/no) Bit 2: N/A Bit 1: Lineside Loopback (yes/no) Bit 0: XFI Loopback (yes/no)
INT wwpLeosPortXcvrXfpWaveLengthTol1.3.6.1.4.1.6141.2.60.4.1.1.1.1.80INTEGERread-onlyThis represents the wavelength tolerance.
INT wwpLeosPortXcvrXfpMaxCaseTemp1.3.6.1.4.1.6141.2.60.4.1.1.1.1.81INTEGERread-onlyThis represents the maximum case temperature.
INT wwpLeosPortXcvrXfpMaxPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.82INTEGERread-onlyThis represents the maximum power dissipation.
INT wwpLeosPortXcvrXfpMax5vCurrent1.3.6.1.4.1.6141.2.60.4.1.1.1.1.83INTEGERread-onlyThis represents the 5.0 Volt Max Current.
INT wwpLeosPortXcvrXfpMax3p3vCurrent1.3.6.1.4.1.6141.2.60.4.1.1.1.1.84INTEGERread-onlyThis represents the 3.3 Volt Max Current.
INT wwpLeosPortXcvrXfpMax1p8vCurrent1.3.6.1.4.1.6141.2.60.4.1.1.1.1.85INTEGERread-onlyThis represents the 1.8 Volt Max Current.
INT wwpLeosPortXcvrXfpMaxNeg5p2vCurrent1.3.6.1.4.1.6141.2.60.4.1.1.1.1.86INTEGERread-onlyThis represents the -5.2 Volt Max Current.
INT wwpLeosPortXcvrXfpDiagMonitorType1.3.6.1.4.1.6141.2.60.4.1.1.1.1.87INTEGERread-onlyThis represents the diag monitor type: Bit 4 indicates BER support. Bit 3 indidates the Rx Power Meas. type of Avg or OMA.
INT wwpLeosPortXcvrXfpEnhancedOptions1.3.6.1.4.1.6141.2.60.4.1.1.1.1.88INTEGERread-onlyThis represents the enhanced options: Bit 7: VPS Support (yes/no) Bit 6: Soft TX_DISABLE (yes/no) Bit 5: Soft P_down (yes/no) Bit 4: VPS LV Regulator Mode (yes/no) Bit 3: VPS bypassed Reg. Mode (yes/no) Bit 2: Active FEC Ctrl (yes/no) Bit 1: Wavelength or frequency Tunability (yes/no) Bit 0: CMU Support Mode (yes/no)
INT wwpLeosPortXcvrXfpAuxMonitoringInput11.3.6.1.4.1.6141.2.60.4.1.1.1.1.89INTEGERread-onlyThis represents the Aux monitoring of A/D input 1.
INT wwpLeosPortXcvrXfpAuxMonitoringInput21.3.6.1.4.1.6141.2.60.4.1.1.1.1.90INTEGERread-onlyThis represents the Aux monitoring of A/D input 2.
U32 wwpLeosPortXcvrAdminFrequency1.3.6.1.4.1.6141.2.60.4.1.1.1.1.91Unsigned32read-writeThe admin frequency of the transceiver in GHz
U32 wwpLeosPortXcvrXfpLaserFirstFrequency1.3.6.1.4.1.6141.2.60.4.1.1.1.1.92Unsigned32read-onlyThis represents the first frequency in GHz
U32 wwpLeosPortXcvrXfpLaserLastFrquency1.3.6.1.4.1.6141.2.60.4.1.1.1.1.93Unsigned32read-onlyThis represents the last frequency in GHz
INT wwpLeosPortXcvrXfpMaxGridScacing1.3.6.1.4.1.6141.2.60.4.1.1.1.1.94INTEGERread-onlyThis represents the maximun support grid spacing in GHz
INT wwpLeosPortXcvrXfpChannelNum1.3.6.1.4.1.6141.2.60.4.1.1.1.1.95INTEGERread-onlyThis represents the channel number
INT wwpLeosPortXcvrXfpFrequencyError1.3.6.1.4.1.6141.2.60.4.1.1.1.1.96INTEGERread-onlyThis represents the frequency error
U32 wwpLeosPortXcvrAdminWavelength1.3.6.1.4.1.6141.2.60.4.1.1.1.1.97Unsigned32read-writeThe admin wavelength of the transceiver in pico-meter
U32 wwpLeosPortXcvrAdminChannel1.3.6.1.4.1.6141.2.60.4.1.1.1.1.98Unsigned32read-writeThe admin channel number of the transceiver
U32 wwpLeosPortXcvrXfpLaserFirstWavelenth1.3.6.1.4.1.6141.2.60.4.1.1.1.1.99Unsigned32read-onlyThis represents the first wavelength in pico meter
U32 wwpLeosPortXcvrXfpLaserLastWavelength1.3.6.1.4.1.6141.2.60.4.1.1.1.1.100Unsigned32read-onlyThis represents the last wavelength in pico meter
U32 wwpLeosPortXcvrXfpLaserFirstChannel1.3.6.1.4.1.6141.2.60.4.1.1.1.1.101Unsigned32read-onlyThis represents the first channel number
U32 wwpLeosPortXcvrXfpLaserLastChannel1.3.6.1.4.1.6141.2.60.4.1.1.1.1.102Unsigned32read-onlyThis represents the last channel number
U32 wwpLeosPortXcvrOperFrequency1.3.6.1.4.1.6141.2.60.4.1.1.1.1.103Unsigned32read-onlyThe operational frequency of the transceiver in GHz
U32 wwpLeosPortXcvrOperWavelength1.3.6.1.4.1.6141.2.60.4.1.1.1.1.104Unsigned32read-onlyThe operational wavelength of the transceiver in pico-meter
I32 wwpLeosPortXcvrRxDbmPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.105Integer32read-onlyIndicates the Rx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
I32 wwpLeosPortXcvrTxDbmPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.106Integer32read-onlyIndicates the Tx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
I32 wwpLeosPortXcvrHighTxDbmPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.107Integer32read-onlyIndicates the higher threshold for Tx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
I32 wwpLeosPortXcvrLowTxDbmPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.108Integer32read-onlyIndicates the lower threshold for Tx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
I32 wwpLeosPortXcvrHighRxDbmPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.109Integer32read-onlyIndicates the higher threshold for Rx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
I32 wwpLeosPortXcvrLowRxDbmPwAlarmThreshold1.3.6.1.4.1.6141.2.60.4.1.1.1.1.110Integer32read-onlyIndicates the lower threshold for Rx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
wwpLeosPortXcvrNotif1.3.6.1.4.1.6141.2.60.4.1.2
INT wwpLeosPortXcvrEventType1.3.6.1.4.1.6141.2.60.4.1.2.1INTEGERread-onlyIndicates if the Xcvr specified by the wwpLeosPortXcvrId has come up, gone down or has been selected.
INT wwpLeosPortXcvrErrorType1.3.6.1.4.1.6141.2.60.4.1.2.2INTEGERread-onlyIndicates if the Xcvr specified by the wwpLeosPortXcvrId is faulted because of checksum failure or optical fault. This object only makes sense if transceiver has been detected faulted otherwise it returns none.
wwpLeosPortXcvrMIBNotificationPrefix1.3.6.1.4.1.6141.2.60.4.2
wwpLeosPortXcvrMIBNotifications1.3.6.1.4.1.6141.2.60.4.2.0
NTF wwpLeosPortXcvrLinkStateChangeNotification1.3.6.1.4.1.6141.2.60.4.2.0.4A wwpLeosPortXcvrLinkStateChangeNotification is sent if the Xcvr state has changed.
NTF wwpLeosPortXcvrErrorTypeNotification1.3.6.1.4.1.6141.2.60.4.2.0.5A wwpLeosPortXcvrErrorTypeNotification is sent if the Xcvr is detected faulted because of some reason. Reason of failure is specified by wwpLeosPortXcvrErrorType.
NTF wwpLeosPortXcvrTempHighNotification1.3.6.1.4.1.6141.2.60.4.2.0.6A wwpLeosPortXcvrTempHighNotification is sent if the Xcvr temperature exceeds the threshold.
NTF wwpLeosPortXcvrTempLowNotification1.3.6.1.4.1.6141.2.60.4.2.0.7A wwpLeosPortXcvrTempLowNotification is sent if the Xcvr temperature decreases the threshold.
NTF wwpLeosPortXcvrTempNormalNotification1.3.6.1.4.1.6141.2.60.4.2.0.8A wwpLeosPortXcvrTempNormalNotification is sent if the Xcvr temperature returns back to normal state.
NTF wwpLeosPortXcvrVoltageHighNotification1.3.6.1.4.1.6141.2.60.4.2.0.9A wwpLeosPortXcvrVoltageHighNotification is sent if the Xcvr voltage exceeds the threshold.
NTF wwpLeosPortXcvrVoltageLowNotification1.3.6.1.4.1.6141.2.60.4.2.0.10A wwpLeosPortXcvrVoltageLowNotification is sent if the Xcvr voltage decreases the threshold.
NTF wwpLeosPortXcvrVoltageNormalNotification1.3.6.1.4.1.6141.2.60.4.2.0.11A wwpLeosPortXcvrVoltageNormalNotification is sent if the Xcvr voltage returns back to normal state.
NTF wwpLeosPortXcvrBiasHighNotification1.3.6.1.4.1.6141.2.60.4.2.0.12A wwpLeosPortXcvrBiasHighNotification is sent if the Xcvr Bias exceeds the threshold.
NTF wwpLeosPortXcvrBiasLowNotification1.3.6.1.4.1.6141.2.60.4.2.0.13A wwpLeosPortXcvrBiasLowNotification is sent if the Xcvr voltage decreases the threshold.
NTF wwpLeosPortXcvrBiasNormalNotification1.3.6.1.4.1.6141.2.60.4.2.0.14A wwpLeosPortXcvrBiasNormalNotification is sent if the Xcvr Bias returns back to normal state.
NTF wwpLeosPortXcvrTxPowerHighNotification1.3.6.1.4.1.6141.2.60.4.2.0.15A wwpLeosPortXcvrTxPowerHighNotification is sent if the Xcvr TxPower exceeds the threshold.
NTF wwpLeosPortXcvrTxPowerLowNotification1.3.6.1.4.1.6141.2.60.4.2.0.16A wwpLeosPortXcvrTxPowerLowNotification is sent if the Xcvr voltage decreases the threshold.
NTF wwpLeosPortXcvrTxPowerNormalNotification1.3.6.1.4.1.6141.2.60.4.2.0.17A wwpLeosPortXcvrTxPowerNormalNotification is sent if the Xcvr TxPower returns back to normal state.
NTF wwpLeosPortXcvrRxPowerHighNotification1.3.6.1.4.1.6141.2.60.4.2.0.18A wwpLeosPortXcvrRxPowerHighNotification is sent if the Xcvr RxPower exceeds the threshold.
NTF wwpLeosPortXcvrRxPowerLowNotification1.3.6.1.4.1.6141.2.60.4.2.0.19A wwpLeosPortXcvrRxPowerLowNotification is sent if the Xcvr voltage decreases the threshold.
NTF wwpLeosPortXcvrRxPowerNormalNotification1.3.6.1.4.1.6141.2.60.4.2.0.20A wwpLeosPortXcvrRxPowerNormalNotification is sent if the Xcvr RxPower returns back to normal state.
NTF wwpLeosPortXcvrSpeedInfoMissingNotification1.3.6.1.4.1.6141.2.60.4.2.0.21A wwpLeosPortXcvrSpeedInfoMissingNotification is sent if the Xcvr speed information is not found.
NTF wwpLeosPortXcvrBiasHighWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.22A wwpLeosPortXcvrBiasHighNotification is sent if the Xcvr Bias exceeds the warning threshold.
NTF wwpLeosPortXcvrBiasLowWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.23A wwpLeosPortXcvrBiasLowNotification is sent if the Xcvr voltage decreases below the warning threshold.
NTF wwpLeosPortXcvrTempHighWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.24A wwpLeosPortXcvrTempHighNotification is sent if the Xcvr temperature exceeds the warning threshold.
NTF wwpLeosPortXcvrTempLowWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.25A wwpLeosPortXcvrTempLowNotification is sent if the Xcvr temperature decreases below the warning threshold.
NTF wwpLeosPortXcvrVoltageHighWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.26A wwpLeosPortXcvrVoltageHighNotification is sent if the Xcvr voltage exceeds the warning threshold.
NTF wwpLeosPortXcvrVoltageLowWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.27A wwpLeosPortXcvrVoltageLowNotification is sent if the Xcvr voltage decreases below the warning threshold.
NTF wwpLeosPortXcvrTxPowerHighWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.28A wwpLeosPortXcvrTxPowerHighNotification is sent if the Xcvr TxPower exceeds the warning threshold.
NTF wwpLeosPortXcvrTxPowerLowWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.29A wwpLeosPortXcvrTxPowerLowNotification is sent if the Xcvr TxPower decreases below the warning threshold.
NTF wwpLeosPortXcvrRxPowerHighWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.30A wwpLeosPortXcvrRxPowerHighNotification is sent if the Xcvr RxPower exceeds the warning threshold.
NTF wwpLeosPortXcvrRxPowerLowWarningNotification1.3.6.1.4.1.6141.2.60.4.2.0.31A wwpLeosPortXcvrRxPowerLowNotification is sent if the Xcvr RxPower decreases below the warning threshold.
wwpLeosPortXcvrMIBConformance1.3.6.1.4.1.6141.2.60.4.3
wwpLeosPortXcvrMIBCompliances1.3.6.1.4.1.6141.2.60.4.3.1
wwpLeosPortXcvrMIBGroups1.3.6.1.4.1.6141.2.60.4.3.2

RFC description

WWP LEOS platform optical transceiver monitoring for ports, signal strength, and laser parameters.

Start monitoring Ciena/World Wide Packets Metro Ethernet switch, optical transceiver ports (Tx/Rx optical-power/temperature/voltage status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download WWP-LEOS-PORT-XCVR-MIB