wwpLeosOamErrFrameSecsSummaryWindow

Module: WWP-LEOS-OAM-MIB

OID (symbolic): WWP-LEOS-OAM-MIB::wwpLeosOamErrFrameSecsSummaryWindow

OID (numeric): 1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The amount of time (in 100ms intervals) over which the threshold is defined. The default value is 100 (10 seconds).

If wwpLeosOamErrFrameSecsSummaryThreshold frame errors occur within a window of wwpLeosOamErrFrameSecsSummaryWindow (in tenths of seconds), an Event Notification OAMPDU should be generated with an Errored Frame Seconds Summary Event TLV indicating the threshold has been crossed in this window.

What is wwpLeosOamErrFrameSecsSummaryWindow?

This sets, in tenths of a second (100-9000, default 100 i.e. 10 seconds), the time window over which the Errored Frame Seconds Summary Event is evaluated, counting how many one-second intervals within the window had at least one frame error. A longer window smooths out brief error bursts and only alerts on sustained, recurring frame-error conditions.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8
snmpwalk -v2c -c public <target> WWP-LEOS-OAM-MIB::wwpLeosOamErrFrameSecsSummaryWindow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8.1
snmpget -v2c -c public <target> WWP-LEOS-OAM-MIB::wwpLeosOamErrFrameSecsSummaryWindow.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8.1 i <value>

Start monitoring Ciena/World Wide Packets Metro Ethernet switch, Ethernet access/first-mile demarcation device (802.3ah OAM peer-discovery/remote-fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WWP-LEOS-OAM-MIB::wwpLeosOamErrFrameSecsSummaryWindow OID value, configure state conditions and alerts, and monitor any Ciena/World Wide Packets Metro Ethernet switch, Ethernet access/first-mile demarcation device (802.3ah OAM peer-discovery/remote-fault status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6141wwpWWP-SMI
1.3.6.1.4.1.6141.2wwpModulesWWP-SMI
1.3.6.1.4.1.6141.2.60wwpModulesLeosWWP-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6141.2.60.400wwpLeosOamMibModuleWWP-LEOS-OAM-MIB
1.3.6.1.4.1.6141.2.60.400.1wwpLeosOamMIBWWP-LEOS-OAM-MIB
1.3.6.1.4.1.6141.2.60.400.1.2wwpLeosOamObjsWWP-LEOS-OAM-MIB
1.3.6.1.4.1.6141.2.60.400.1.2.6wwpLeosOamEventConfigTableWWP-LEOS-OAM-MIB
1.3.6.1.4.1.6141.2.60.400.1.2.6.1wwpLeosOamEventConfigEntryWWP-LEOS-OAM-MIB
1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8wwpLeosOamErrFrameSecsSummaryWindowWWP-LEOS-OAM-MIB