WWP-LEOS-DNS-CLIENT-MIB :: wwpLeosDnsServerInetAddrType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WWP-LEOS-DNS-CLIENT-MIB › wwpLeosDnsServerInetAddrType

wwpLeosDnsServerInetAddrType

Module: WWP-LEOS-DNS-CLIENT-MIB

OID (symbolic): WWP-LEOS-DNS-CLIENT-MIB::wwpLeosDnsServerInetAddrType

OID (numeric): 1.3.6.1.4.1.6141.2.60.16.1.1.6.1.7

Node type: OBJECT-TYPE

Type: InetAddressType

Access: read-write

Description: The Inet address type for the configured DNS Server. Used in conjunction with wwpLeosDnsServerInetAddr. When set to: ipv4 : wwpLeosDnsServerInetAddr should be compliant with InetAddressIPv4 from RFC 4001 ipv6 : wwpLeosDnsServerInetAddr should be compliant with InetAddressIPv6 from RFC 4001

What is wwpLeosDnsServerInetAddrType?

This read-write value indicates the address family, ipv4 or ipv6, of the address held in the paired wwpLeosDnsServerInetAddr object for this DNS server entry. Admins set it together with wwpLeosDnsServerInetAddr when configuring a DNS server using the version-neutral addressing scheme, which is required for IPv6 DNS servers since the older wwpLeosDnsServerAddr object only supports IPv4. For example, setting this to ipv6 and wwpLeosDnsServerInetAddr to an IPv6 literal configures an IPv6 DNS server on the device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6141.2.60.16.1.1.6.1.7
snmpwalk -v2c -c public <target> WWP-LEOS-DNS-CLIENT-MIB::wwpLeosDnsServerInetAddrType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6141.2.60.16.1.1.6.1.7.1
snmpget -v2c -c public <target> WWP-LEOS-DNS-CLIENT-MIB::wwpLeosDnsServerInetAddrType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6141.2.60.16.1.1.6.1.7.1 s <value>

Start monitoring Ciena/World Wide Packets Metro Ethernet switch (DNS resolver server-list/domain-suffix config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WWP-LEOS-DNS-CLIENT-MIB::wwpLeosDnsServerInetAddrType OID value, configure state conditions and alerts, and monitor any Ciena/World Wide Packets Metro Ethernet switch (DNS resolver server-list/domain-suffix config status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6141wwpWWP-SMI
1.3.6.1.4.1.6141.2wwpModulesWWP-SMI
1.3.6.1.4.1.6141.2.60wwpModulesLeosWWP-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6141.2.60.16wwpLeosDnsClientMIBWWP-LEOS-DNS-CLIENT-MIB
1.3.6.1.4.1.6141.2.60.16.1wwpLeosDnsClientMIBObjectsWWP-LEOS-DNS-CLIENT-MIB
1.3.6.1.4.1.6141.2.60.16.1.1wwpLeosDnsClientWWP-LEOS-DNS-CLIENT-MIB
1.3.6.1.4.1.6141.2.60.16.1.1.6wwpLeosDnsServerTableWWP-LEOS-DNS-CLIENT-MIB
1.3.6.1.4.1.6141.2.60.16.1.1.6.1wwpLeosDnsServerEntryWWP-LEOS-DNS-CLIENT-MIB
1.3.6.1.4.1.6141.2.60.16.1.1.6.1.7wwpLeosDnsServerInetAddrTypeWWP-LEOS-DNS-CLIENT-MIB