All MIBs › WSD-MIB › rsWSDTokenDefault
rsWSDTokenDefault
Module: WSD-MIB
OID (symbolic): WSD-MIB::rsWSDTokenDefault
OID (numeric): 1.3.6.1.4.1.89.35.1.40.38.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Indication whether this farm is the default one. noToken indicates that the farm should be used as default when no matching token was found. noHeaderField indicates that the farm should be used when no matching header field was found, and alwaysDefault indicates that this farm should be used in either case.
What is rsWSDTokenDefault?
Marks whether this farm is the default: notDefault(1), noToken(2) to use it when no matching token was found, noHeaderField(3) to use it when the header field is missing, or alwaysDefault(4) to use it in either case. Set one farm as a catch-all so unmatched requests still get served.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.35.1.40.38.1.4 snmpwalk -v2c -c public <target> WSD-MIB::rsWSDTokenDefault
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.89.35.1.40.38.1.4.1 snmpget -v2c -c public <target> WSD-MIB::rsWSDTokenDefault.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.89.35.1.40.38.1.4.1 i <value>
Start monitoring load balancer / application delivery controller (Radware-style), web/application server farm monitored by the device (server oper-status/load status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WSD-MIB::rsWSDTokenDefault OID value, configure state conditions and alerts, and monitor any load balancer / application delivery controller (Radware-style), web/application server farm monitored by the device (server oper-status/load status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.89 | rnd | Dell-MIB |
| 1.3.6.1.4.1.89.35 | rndApplications | Dell-MIB |
| 1.3.6.1.4.1.89.35.1 | rsServerDispatcher | RADWARE-MIB |
| 1.3.6.1.4.1.89.35.1.40 | rsNWSD | RADWARE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.89.35.1.40.38 | rsWSDTokenTable | WSD-MIB |
| 1.3.6.1.4.1.89.35.1.40.38.1 | rsWSDTokenTableEntry | WSD-MIB |
| 1.3.6.1.4.1.89.35.1.40.38.1.4 | rsWSDTokenDefault | WSD-MIB |