TPT-NGFW-CLUSTER-MIB :: tptNgfwClusterHaFeatSyncStatusTotalEntries

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTPT-NGFW-CLUSTER-MIBtptNgfwClusterHaFeatSyncStatusTotalEntries

tptNgfwClusterHaFeatSyncStatusTotalEntries

Module: TPT-NGFW-CLUSTER-MIB

OID (symbolic): TPT-NGFW-CLUSTER-MIB::tptNgfwClusterHaFeatSyncStatusTotalEntries

OID (numeric): 1.3.6.1.4.1.10734.3.9.2.2.11.7.1.5

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total number of entries for the feature.

What is tptNgfwClusterHaFeatSyncStatusTotalEntries?

This is the total number of synchronized state entries currently held for a specific feature. Admins use this as a size indicator for how much state a given feature is tracking across the HA pair, useful when comparing against add/delete counters to gauge churn.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10734.3.9.2.2.11.7.1.5
snmpwalk -v2c -c public <target> TPT-NGFW-CLUSTER-MIB::tptNgfwClusterHaFeatSyncStatusTotalEntries

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10734.3.9.2.2.11.7.1.5.1
snmpget -v2c -c public <target> TPT-NGFW-CLUSTER-MIB::tptNgfwClusterHaFeatSyncStatusTotalEntries.1

Start monitoring Trend Micro TippingPoint NGFW appliances with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TPT-NGFW-CLUSTER-MIB::tptNgfwClusterHaFeatSyncStatusTotalEntries OID value, configure state conditions and alerts, and monitor any Trend Micro TippingPoint NGFW appliances from a single console.

How to Use in IPNetwork Monitor

Select a Trend Micro TippingPoint NGFW appliance as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tptNgfwClusterHaFeatSyncStatusTotalEntries into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of entries for the feature. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.10734tippingpointTIPPINGPOINT-REG-MIB
1.3.6.1.4.1.10734.3tpt_productsTIPPINGPOINT-REG-MIB
1.3.6.1.4.1.10734.3.9tpt_ngfwMIBsTPT-NGFW-REG-MIB
1.3.6.1.4.1.10734.3.9.2tpt_ngfw_objsTPT-NGFW-REG-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10734.3.9.2.2tptNgfwClusterTPT-NGFW-CLUSTER-MIB
1.3.6.1.4.1.10734.3.9.2.2.11tptNgfwClusterHaTPT-NGFW-CLUSTER-MIB
1.3.6.1.4.1.10734.3.9.2.2.11.7tptNgfwClusterHaFeatSyncStatusTableTPT-NGFW-CLUSTER-MIB
1.3.6.1.4.1.10734.3.9.2.2.11.7.1tptNgfwClusterHaFeatSyncStatusTableEntryTPT-NGFW-CLUSTER-MIB
1.3.6.1.4.1.10734.3.9.2.2.11.7.1.5tptNgfwClusterHaFeatSyncStatusTotalEntriesTPT-NGFW-CLUSTER-MIB