All MIBs › TN-SAS-PORT-MIB › tnPortEtherClockConfig
tnPortEtherClockConfig
Module: TN-SAS-PORT-MIB
OID (symbolic): TN-SAS-PORT-MIB::tnPortEtherClockConfig
OID (numeric): 1.3.6.1.4.1.7483.7.2.2.2.2.4.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: When the value of tnPortEtherClockConfig is 'automatic' the Ethernet interface will automatically negotiate clock mastership along with other link parameters with the far end. Depending upon the capabilities of the two ends, one will be master the other will be slave for clocking. When the value of tnPortEtherClockConfig is 'manual-master', the Ethernet interface will negotiate other link parameters with the far end except clock mastership. It assumes clock mastership and want the other end to be slave. When the value is 'manual-slave' this ethernet interface chooses to be slave and wants the far end to assume clock mastership. For 10 baseT and 100 baseT ethernet interfaces, value of this variable should be 'none', as this will not be applicable for those interfaces.
What is tnPortEtherClockConfig?
Controls clock mastership negotiation on this Ethernet interface: automatic(1) negotiates mastership with the far end, manual-master(2) forces this end to be clock master, manual-slave(3) forces this end to be clock slave, and notApplicable(0) — the required setting for 10baseT/100baseT ports — disables clocking negotiation entirely.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7483.7.2.2.2.2.4.1.13 snmpwalk -v2c -c public <target> TN-SAS-PORT-MIB::tnPortEtherClockConfig
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.7483.7.2.2.2.2.4.1.13.1 snmpget -v2c -c public <target> TN-SAS-PORT-MIB::tnPortEtherClockConfig.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.7483.7.2.2.2.2.4.1.13.1 i <value>
Start monitoring Nokia 7x50 service routers, SAS/satellite access shelf ports (split-horizon-group/QoS-policy port status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TN-SAS-PORT-MIB::tnPortEtherClockConfig OID value, configure state conditions and alerts, and monitor any Nokia 7x50 service routers, SAS/satellite access shelf ports (split-horizon-group/QoS-policy port status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.7483 | tropic | TROPIC-GLOBAL-REG |
| 1.3.6.1.4.1.7483.7 | tnSASProducts | TROPIC-GLOBAL-REG |
| 1.3.6.1.4.1.7483.7.2 | tnServiceAccessSwitches | TROPIC-GLOBAL-REG |
| 1.3.6.1.4.1.7483.7.2.2 | tnSASMIB | TROPIC-GLOBAL-REG |
| 1.3.6.1.4.1.7483.7.2.2.2 | tnSASObjs | TROPIC-GLOBAL-REG |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.7483.7.2.2.2.2 | tnSASPortObjs | TN-SAS-PORT-MIB |
| 1.3.6.1.4.1.7483.7.2.2.2.2.4 | tnSASPortEtherExtnTable | TN-SAS-PORT-MIB |
| 1.3.6.1.4.1.7483.7.2.2.2.2.4.1 | tnSASPortEtherExtnEntry | TN-SAS-PORT-MIB |
| 1.3.6.1.4.1.7483.7.2.2.2.2.4.1.13 | tnPortEtherClockConfig | TN-SAS-PORT-MIB |