TM63-MIB :: statLOES

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TM63-MIB › statLOES

statLOES

Module: TM63-MIB

OID (symbolic): TM63-MIB::statLOES

OID (numeric): 1.3.6.1.4.1.5746.1.2.3.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Stan rejestru Sygnalow Skladowych 1-16 Zanik sygnau skadowego przychodzcego do wejcia (ZSSx=1 - zanik sygnau, ZSSx=0 - sygna obecny, gdzie: x - numer kanalu). bit : 15 14 13 12 11 10 9 8 nazwa : ZSS16 ZSS15 ZSS14 ZSS13 ZSS12 ZSS11 ZSS10 ZSS9

bit : 7 6 5 4 3 2 1 0 nazwa : ZSS8 ZSS7 ZSS6 ZSS5 ZSS4 ZSS3 ZSS2 ZSS1

What is statLOES?

A 16-bit read-only status register showing loss of signal on each of the 16 E1 tributary inputs (bit=1 means that channel's incoming signal is lost); admins read this to quickly see which tributary channels have a cabling or far-end problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5746.1.2.3.1
snmpwalk -v2c -c public <target> TM63-MIB::statLOES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5746.1.2.3.1.1
snmpget -v2c -c public <target> TM63-MIB::statLOES.1

Start monitoring Lanex telecom transmission equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TM63-MIB::statLOES OID value, configure state conditions and alerts, and monitor any Lanex telecom transmission equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5746lanexTM62-MIB
1.3.6.1.4.1.5746.1telecomTM62-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5746.1.2optiLine16TM63-MIB
1.3.6.1.4.1.5746.1.2.3statusTM63-MIB
1.3.6.1.4.1.5746.1.2.3.1statLOESTM63-MIB