All MIBs › TM63-MIB › testGeneratorDetector
testGeneratorDetector
Module: TM63-MIB
OID (symbolic): TM63-MIB::testGeneratorDetector
OID (numeric): 1.3.6.1.4.1.5746.1.2.6.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: numer generatora/detektora wykorzystywanego do testu 1..16 - generator w kierunku kanalu skladowego (E1) 1..16 17 - generator w kierunku kanalu zbiorczego (E3)
What is testGeneratorDetector?
Selects which channel's test-signal generator/detector pair is active for BER testing: values 1-16 select one of the 16 E1 tributary channels, and 17 selects the E3 aggregate channel.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5746.1.2.6.5 snmpwalk -v2c -c public <target> TM63-MIB::testGeneratorDetector
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5746.1.2.6.5.1 snmpget -v2c -c public <target> TM63-MIB::testGeneratorDetector.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5746.1.2.6.5.1 i <value>
Start monitoring Lanex telecom transmission equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TM63-MIB::testGeneratorDetector OID value, configure state conditions and alerts, and monitor any Lanex telecom transmission equipment from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5746 | lanex | TM62-MIB |
| 1.3.6.1.4.1.5746.1 | telecom | TM62-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5746.1.2 | optiLine16 | TM63-MIB |
| 1.3.6.1.4.1.5746.1.2.6 | test | TM63-MIB |
| 1.3.6.1.4.1.5746.1.2.6.5 | testGeneratorDetector | TM63-MIB |