TIMETRA-OES-HARDWARE-MIB :: tmnxOesRedundancyFail

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › TIMETRA-OES-HARDWARE-MIB › tmnxOesRedundancyFail

tmnxOesRedundancyFail

Module: TIMETRA-OES-HARDWARE-MIB

OID (symbolic): TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.99.1.30

Node type: NOTIFICATION-TYPE

Description: [CAUSE] The tmnxOesRedundancyFail notification is generated when the inactive equipment controller card in the OES is not providing redundancy protection. In some cases this is a transitory alarm that occurs as redundant Equipment Controllers discover one another and synchronize. Typical causes for the persistence of this alarm are: 1) Irreconcilable database schemas. 2) Inability to support system timing. 3) System timing is compromised. The inactive controller system timing module is not reporting the same status as the active controller or is reporting an error that the active controller does not have. 4) Subshelf link missing. Reasons that are generally transitory are: 1) Database not yet fully synchronized. 2) Software loads are not yet synchronized. Some or all of these may apply when the alarm is raised.

[EFFECT] The OES is not protected against failure of the active Equipment Controller.

[RECOVERY] Check for the Redundancy demerit in the detailed information of the chassis indicated.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.99.1.30

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:64551->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (348132391) 40 days, 7:02:03.91
  SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail

Start monitoring Nokia/Alcatel-Lucent 7750 SR router with Optical Extension Shelf (OES chassis hardware inventory/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7750 SR router with Optical Extension Shelf (OES chassis hardware inventory/status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.3.99tmnxOesHwMIBNotifyPrefixTIMETRA-OES-HARDWARE-MIB
1.3.6.1.4.1.6527.3.1.3.99.1tmnxOesHwNotificationsTIMETRA-OES-HARDWARE-MIB
1.3.6.1.4.1.6527.3.1.3.99.1.30tmnxOesRedundancyFailTIMETRA-OES-HARDWARE-MIB