TIMETRA-OES-HARDWARE-MIB :: tmnxOesCtlCardPortDown

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › TIMETRA-OES-HARDWARE-MIB › tmnxOesCtlCardPortDown

tmnxOesCtlCardPortDown

Module: TIMETRA-OES-HARDWARE-MIB

OID (symbolic): TIMETRA-OES-HARDWARE-MIB::tmnxOesCtlCardPortDown

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.99.1.1

Node type: NOTIFICATION-TYPE

Description: [CAUSE] The tmnxOesCtlCardPortDown notification is generated when a port (e.g. ES 1 or AUX) on an OES Control Card (e.g. EC card) is not operational. The reason may be a misconnected, disconnected or faulty cable, a faulty port or Control Card.

[EFFECT] If an ES (Extension Shelf) port is down then one of the control plane communication paths between EC (Equipment Controller) cards in different OES Chassis is not available. The control communications with one or more OES subtending chassis may be affected rendering the Chassis unmanageable. Other control paths may be available.

If an AUX port is down then one of the control plane communication paths between the router and the OES Master Chassis is not available and control communications with the OES may be affected rendering the OES unmanageable. Other control paths may be available.

[RECOVERY] Check that the cable is correctly connected and test the cable.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' TIMETRA-OES-HARDWARE-MIB::tmnxOesCtlCardPortDown
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.99.1.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:50557->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (509886845) 59 days, 0:21:08.45
  SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-OES-HARDWARE-MIB::tmnxOesCtlCardPortDown

Start monitoring Nokia/Alcatel-Lucent 7750 SR router with Optical Extension Shelf (OES chassis hardware inventory/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-HARDWARE-MIB::tmnxOesCtlCardPortDown OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7750 SR router with Optical Extension Shelf (OES chassis hardware inventory/status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.3.99tmnxOesHwMIBNotifyPrefixTIMETRA-OES-HARDWARE-MIB
1.3.6.1.4.1.6527.3.1.3.99.1tmnxOesHwNotificationsTIMETRA-OES-HARDWARE-MIB
1.3.6.1.4.1.6527.3.1.3.99.1.1tmnxOesCtlCardPortDownTIMETRA-OES-HARDWARE-MIB