TIMETRA-OES-HARDWARE-MIB :: tmnxOesCardDegraded

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › TIMETRA-OES-HARDWARE-MIB › tmnxOesCardDegraded

tmnxOesCardDegraded

Module: TIMETRA-OES-HARDWARE-MIB

OID (symbolic): TIMETRA-OES-HARDWARE-MIB::tmnxOesCardDegraded

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.99.1.23

Node type: NOTIFICATION-TYPE

Description: [CAUSE] The tmnxOesCardDegraded notification is generated when a fault on the card has caused the system to declare a hardware failure. This condition may be declared due to a failure in the SEEP or another hardware failure, depending on the card type the alarm is raised against.

[EFFECT] The tmnxOesCardDegraded alarm indicates a lower priority fault on the card that does not directly affect the traffic currently flowing through the device.

[RECOVERY] First attempt a soft reset of the card. If the card has rebooted and the condition does not clear, then try a hard reset of the card. If the card has rebooted and the condition does not clear, then remove the card and re-insert it to see if the condition clears. If the condition remains, then replace the card and follow the return and repair process for the problem card.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' TIMETRA-OES-HARDWARE-MIB::tmnxOesCardDegraded
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.99.1.23

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:56540->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (240843996) 27 days, 21:00:39.96
  SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-OES-HARDWARE-MIB::tmnxOesCardDegraded

Start monitoring Nokia/Alcatel-Lucent 7750 SR router with Optical Extension Shelf (OES chassis hardware inventory/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-HARDWARE-MIB::tmnxOesCardDegraded OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7750 SR router with Optical Extension Shelf (OES chassis hardware inventory/status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.3.99tmnxOesHwMIBNotifyPrefixTIMETRA-OES-HARDWARE-MIB
1.3.6.1.4.1.6527.3.1.3.99.1tmnxOesHwNotificationsTIMETRA-OES-HARDWARE-MIB
1.3.6.1.4.1.6527.3.1.3.99.1.23tmnxOesCardDegradedTIMETRA-OES-HARDWARE-MIB