TIMETRA-CHASSIS-MIB :: tmnxSyncIfTimingRef2State

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTIMETRA-CHASSIS-MIBtmnxSyncIfTimingRef2State

tmnxSyncIfTimingRef2State

Module: TIMETRA-CHASSIS-MIB

OID (symbolic): TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingRef2State

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.39

Node type: OBJECT-TYPE

Type: TmnxRefInState

Access: read-only

Description: The value of tmnxSyncIfTimingRef2State indicates the operational state of the Reference 2 Timing.

What is tmnxSyncIfTimingRef2State?

This object reports the operational status of the secondary timing reference input on the system, which is used for synchronizing the network element's internal clock. Network operators monitor this value to ensure the system has at least one valid timing source; if both primary and secondary references fail, the system falls back to local oscillator and timing accuracy degrades. Proper timing is critical for protocols like SONET/SDH and LTE.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.39
snmpwalk -v2c -c public <target> TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingRef2State

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.39.1
snmpget -v2c -c public <target> TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingRef2State.1

Start monitoring Nokia/Alcatel-Lucent 7x50 SR-series service routers, entire product line (chassis/slot/port hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingRef2State OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7x50 SR-series service routers, entire product line (chassis/slot/port hardware inventory) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2.2tmnxHwObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3tmnxCardObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3.11tmnxSyncIfTimingTableALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3.11.1tmnxSyncIfTimingEntryALCATEL-IND1-TIMETRA-CHASSIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.39tmnxSyncIfTimingRef2StateTIMETRA-CHASSIS-MIB