TIMETRA-CHASSIS-MIB :: tmnxSyncIfTimingOtherCPMAlarm

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTIMETRA-CHASSIS-MIBtmnxSyncIfTimingOtherCPMAlarm

tmnxSyncIfTimingOtherCPMAlarm

Module: TIMETRA-CHASSIS-MIB

OID (symbolic): TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingOtherCPMAlarm

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.48

Node type: OBJECT-TYPE

Type: TmnxSETSRefAlarm

Access: read-only

Description: The value of tmnxSyncIfTimingOtherCPMAlarm indicates the alarms on the timing reference from the other CPM. If any of the bits is set to '1', then the reference is disqualified by the timing subsystem and the value of tmnxSyncIfTimingOtherCPMQual is set to 'not-qualified'.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.48
snmpwalk -v2c -c public <target> TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingOtherCPMAlarm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.48.1
snmpget -v2c -c public <target> TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingOtherCPMAlarm.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> tmnxSyncIfTimingOtherCPMAlarm.1

Start monitoring Nokia/Alcatel-Lucent 7x50 SR-series service routers, entire product line (chassis/slot/port hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-CHASSIS-MIB::tmnxSyncIfTimingOtherCPMAlarm OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7x50 SR-series service routers, entire product line (chassis/slot/port hardware inventory) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2.2tmnxHwObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3tmnxCardObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3.11tmnxSyncIfTimingTableALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3.11.1tmnxSyncIfTimingEntryALCATEL-IND1-TIMETRA-CHASSIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.48tmnxSyncIfTimingOtherCPMAlarmTIMETRA-CHASSIS-MIB