TIMETRA-CHASSIS-MIB :: tmnxMDAIngHsmdaSchedPolicy

MIB Reference — IPNetwork Monitor · Updated September 30, 2026

All MIBs › TIMETRA-CHASSIS-MIB › tmnxMDAIngHsmdaSchedPolicy

tmnxMDAIngHsmdaSchedPolicy

Module: TIMETRA-CHASSIS-MIB

OID (symbolic): TIMETRA-CHASSIS-MIB::tmnxMDAIngHsmdaSchedPolicy

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.26

Node type: OBJECT-TYPE

Type: TNamedItemOrEmpty

Access: read-write

Description: The value of tmnxMDAIngHsmdaSchedPolicy specifies the name of High Scale MDA (HSMDA) scheduler policy to use on the ingress of the MDA.

An 'inconsistentValue' error is returned if this object is set to a value which does not have a corresponding entry in TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyTable.

When the value of tmnxMDAAssignedType specifies a non-HSMDA MDA Type, an 'inconsistentValue' error is returned if this object is set to any non-empty string.

This object is obsoleted in 10.0 Release.

What is tmnxMDAIngHsmdaSchedPolicy?

This read-write string, now marked obsolete (replaced in the 10.0 release), specified the name of a High Scale MDA (HSMDA) scheduler policy to apply on the ingress side of an MDA, and had to reference a real entry in TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyTable. On current releases the newer egress/ingress HSMDA policy objects should be used instead; this field is retained mainly for legacy configuration compatibility.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.26
snmpwalk -v2c -c public <target> TIMETRA-CHASSIS-MIB::tmnxMDAIngHsmdaSchedPolicy

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.26.1
snmpget -v2c -c public <target> TIMETRA-CHASSIS-MIB::tmnxMDAIngHsmdaSchedPolicy.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.26.1 s <value>

Start monitoring Nokia/Alcatel-Lucent 7x50 SR-series service routers, entire product line (chassis/slot/port hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-CHASSIS-MIB::tmnxMDAIngHsmdaSchedPolicy OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7x50 SR-series service routers, entire product line (chassis/slot/port hardware inventory) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2.2tmnxHwObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3tmnxCardObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3.8tmnxMDATableALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.3.8.1tmnxMDAEntryALCATEL-IND1-TIMETRA-CHASSIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.2.3.8.1.26tmnxMDAIngHsmdaSchedPolicyTIMETRA-CHASSIS-MIB