TIMETRA-CHASSIS-MIB :: tmnxEqSyncIfTimingSystemQuality

MIB Reference — IPNetwork Monitor

All MIBsTIMETRA-CHASSIS-MIBtmnxEqSyncIfTimingSystemQuality

tmnxEqSyncIfTimingSystemQuality

Module: TIMETRA-CHASSIS-MIB

OID (symbolic): TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingSystemQuality

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.2.1.0.65

Node type: NOTIFICATION-TYPE

Description:

The tmnxEqSyncIfTimingSystemQuality notification is generated when there is a change in the system timing quality level. This notification is a point-in-time state change event.

[CAUSE] This notification may be triggered for the following reasons:

1) There has been a switch in the timing reference in use by the network element, either because the previously active timing reference was disqualified, or to ensure that the network element is using the timing reference with the best timing quality. 2) There has been a change in the active timing reference's quality and the change does not result in a timing reference switch. 3) The network element has transitioned into or out of the holdover state.

[EFFECT] The system quality level is used to determine the SSM code transmitted on synchronous interfaces. This may affect the SSM code transmitted on some or all interfaces, which may affect the distribution of timing throughout the network.

[RECOVERY] If the customer is expecting the system to be locked to a reference of a particular quality and the system quality has decreased, the customer will need to determine the root cause (for example, loss of communication with a satellite) and resolve the issue.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingSystemQuality
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.2.1.0.65

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:52155->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (506744763) 58 days, 15:37:27.63
  SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingSystemQuality

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3.2tmnxHwNotificationALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.3.2.1tmnxChassisNotifyPrefixALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.3.2.1.0tmnxChassisNotificationALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.3.2.1.0.65tmnxEqSyncIfTimingSystemQualityTIMETRA-CHASSIS-MIB