All MIBs › TIMETRA-CHASSIS-INTERCONNECT-MIB › tmnxSfmIcPortDegraded
tmnxSfmIcPortDegraded
Module: TIMETRA-CHASSIS-INTERCONNECT-MIB
OID (symbolic): TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxSfmIcPortDegraded
OID (numeric): 1.3.6.1.4.1.6527.3.1.3.94.0.3.8
Node type: NOTIFICATION-TYPE
Description: [CAUSE] The tmnxSfmIcPortDegraded notification is generated when the system has detected a degradation of the switch fabric that is associated with a particular SFM interconnect port. The value of tmnxSfmIcPortDegradeState will reflect this condition by having a value that is NOT 'none (1)'. If the value of tmnxSfmIcPortDegradeState is 'degraded (2)' the SFM interconnect port can still carry some traffic but not at the full capacity of the port. The port and attached cable are not necessarily the cause of the degradation but are a likely cause.
[EFFECT] Switch fabric capacity on this port is reduced when tmnxSfmIcPortDegradeState is degraded. This may not be causing any impact to service because of redundancy in the fabric.
[RECOVERY] Although it may not be necessary to maintain full service, replacing the affected components may restore some fabric capacity.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxSfmIcPortDegraded snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.94.0.3.8
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:63915->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (48763307) 5 days, 15:27:13.07 SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxSfmIcPortDegraded
Start monitoring Nokia/Alcatel-Lucent 7750 SR/7950 XRS multi-chassis router (interconnect port/SFF transceiver status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxSfmIcPortDegraded OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7750 SR/7950 XRS multi-chassis router (interconnect port/SFF transceiver status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6527 | timetra | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3 | timetraProducts | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1 | tmnxSRMIB | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1.3 | tmnxSRNotifyPrefix | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6527.3.1.3.94 | tmnxChassisInterconNotifyPrefix | TIMETRA-CHASSIS-INTERCONNECT-MIB |
| 1.3.6.1.4.1.6527.3.1.3.94.0 | tmnxChassisInterconNotification | TIMETRA-CHASSIS-INTERCONNECT-MIB |
| 1.3.6.1.4.1.6527.3.1.3.94.0.3 | tmnxSfmIcPortNotifications | TIMETRA-CHASSIS-INTERCONNECT-MIB |
| 1.3.6.1.4.1.6527.3.1.3.94.0.3.8 | tmnxSfmIcPortDegraded | TIMETRA-CHASSIS-INTERCONNECT-MIB |