TIMETRA-CHASSIS-INTERCONNECT-MIB :: tmnxCpmNoLocalIcPort

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › TIMETRA-CHASSIS-INTERCONNECT-MIB › tmnxCpmNoLocalIcPort

tmnxCpmNoLocalIcPort

Module: TIMETRA-CHASSIS-INTERCONNECT-MIB

OID (symbolic): TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxCpmNoLocalIcPort

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.94.0.2.5

Node type: NOTIFICATION-TYPE

Description: [CAUSE] The tmnxCpmNoLocalIcPort alarm is generated when the CPM cannot reach the other chassis using its local CPM interconnect ports.

[EFFECT] Another control communications path may still be available between the CPM and the other chassis via the mate CPM in the same chassis. If that alternative path is not available then complete disruption of control communications to the other chassis will occur and the tmnxInterChassisCommsDown alarm is raised.

A tmnxCpmNoLocalIcPort alarm on the active CPM indicates that a further failure of the local CPM interconnect ports on the standby CPM will cause complete disruption of control communications to the other chassis and the tmnxInterChassisCommsDown alarm is raised.

A tmnxCpmNoLocalIcPort alarm on the standby CPM indicates that a CPM switchover may cause temporary disruption of control communications to the other chassis while the rebooting CPM comes back into service.

[RECOVERY] Ensure that all CPM interconnect ports in the system are properly cabled together with working cables.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxCpmNoLocalIcPort
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.94.0.2.5

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:61217->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (285190945) 33 days, 0:11:49.45
  SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxCpmNoLocalIcPort

Start monitoring Nokia/Alcatel-Lucent 7750 SR/7950 XRS multi-chassis router (interconnect port/SFF transceiver status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-CHASSIS-INTERCONNECT-MIB::tmnxCpmNoLocalIcPort OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7750 SR/7950 XRS multi-chassis router (interconnect port/SFF transceiver status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.3.94tmnxChassisInterconNotifyPrefixTIMETRA-CHASSIS-INTERCONNECT-MIB
1.3.6.1.4.1.6527.3.1.3.94.0tmnxChassisInterconNotificationTIMETRA-CHASSIS-INTERCONNECT-MIB
1.3.6.1.4.1.6527.3.1.3.94.0.2tmnxCpmIcPortNotificationsTIMETRA-CHASSIS-INTERCONNECT-MIB
1.3.6.1.4.1.6527.3.1.3.94.0.2.5tmnxCpmNoLocalIcPortTIMETRA-CHASSIS-INTERCONNECT-MIB