TAIT-TN9300-MIB :: tn9300Mpt1327RxBytes

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TAIT-TN9300-MIB › tn9300Mpt1327RxBytes

tn9300Mpt1327RxBytes

Module: TAIT-TN9300-MIB

OID (symbolic): TAIT-TN9300-MIB::tn9300Mpt1327RxBytes

OID (numeric): 1.3.6.1.4.1.3570.3.6.2.5.5

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of bytes received from the MPT1327 Gateway.

What is tn9300Mpt1327RxBytes?

A running counter of bytes received from the MPT1327 Gateway. Used to confirm data is actually flowing inbound over the gateway link, e.g. spotting the counter stalling during an outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3570.3.6.2.5.5
snmpwalk -v2c -c public <target> TAIT-TN9300-MIB::tn9300Mpt1327RxBytes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3570.3.6.2.5.5.1
snmpget -v2c -c public <target> TAIT-TN9300-MIB::tn9300Mpt1327RxBytes.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> tn9300Mpt1327RxBytes.1

Start monitoring Tait TaitNet TN9300 DMR node controller (node state/peer connectivity/call-switching status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TAIT-TN9300-MIB::tn9300Mpt1327RxBytes OID value, configure state conditions and alerts, and monitor any Tait TaitNet TN9300 DMR node controller (node state/peer connectivity/call-switching status) from a single console.

How to Use in IPNetwork Monitor

Select a Tait TaitNet TN9300 DMR node controller (node state/peer connectivity/call-switching status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tn9300Mpt1327RxBytes into the Find box to locate it in the OID tree, then select it and click OK. The number of bytes received from the MPT1327 Gateway. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3570taitTAIT-COMMON-MIB
1.3.6.1.4.1.3570.3taitProductsTAIT-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3570.3.6tn9300MIBTAIT-TN9300-MIB
1.3.6.1.4.1.3570.3.6.2tn9300ObjsTAIT-TN9300-MIB
1.3.6.1.4.1.3570.3.6.2.5tn9300Mpt1327ObjsTAIT-TN9300-MIB
1.3.6.1.4.1.3570.3.6.2.5.5tn9300Mpt1327RxBytesTAIT-TN9300-MIB