All MIBs › T11-FC-VIRTUAL-FABRIC-MIB › t11vfPortStorageType
t11vfPortStorageType
Module: T11-FC-VIRTUAL-FABRIC-MIB
OID (symbolic): T11-FC-VIRTUAL-FABRIC-MIB::t11vfPortStorageType
OID (numeric): 1.3.6.1.2.1.147.1.3.1.4
Node type: OBJECT-TYPE
Type: StorageType
Access: read-write
Description: The storage type for this conceptual row, and for the corresponding row in the augmented fcmPortTable.
Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row.
What is t11vfPortStorageType?
This object indicates the storage type for a Virtual Fabric port entry's conceptual row, and by extension the corresponding row in the switch's port table. Admins use it to know whether that port's Virtual Fabric tagging configuration persists across a device reboot. For example, a row marked nonVolatile would confirm the port's VF_ID and tagging settings survive a restart.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.147.1.3.1.4 snmpwalk -v2c -c public <target> T11-FC-VIRTUAL-FABRIC-MIB::t11vfPortStorageType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.147.1.3.1.4.1 snmpget -v2c -c public <target> T11-FC-VIRTUAL-FABRIC-MIB::t11vfPortStorageType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.147.1.3.1.4.1 s <value>
Start monitoring vendor-neutral, standards-based MIB (IETF RFC 4747 / T11 FC-SW), Fibre Channel switches/directors supporting Virtual Fabrics with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the T11-FC-VIRTUAL-FABRIC-MIB::t11vfPortStorageType OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB (IETF RFC 4747 / T11 FC-SW), Fibre Channel switches/directors supporting Virtual Fabrics from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.147 | t11FcVirtualFabricMIB | T11-FC-VIRTUAL-FABRIC-MIB |
| 1.3.6.1.2.1.147.1 | t11vfObjects | T11-FC-VIRTUAL-FABRIC-MIB |
| 1.3.6.1.2.1.147.1.3 | t11vfPortTable | T11-FC-VIRTUAL-FABRIC-MIB |
| 1.3.6.1.2.1.147.1.3.1 | t11vfPortEntry | T11-FC-VIRTUAL-FABRIC-MIB |
| 1.3.6.1.2.1.147.1.3.1.4 | t11vfPortStorageType | T11-FC-VIRTUAL-FABRIC-MIB |