T11-FC-NAME-SERVER-MIB :: t11NsInfoSubsetSwitchIndex

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsT11-FC-NAME-SERVER-MIBt11NsInfoSubsetSwitchIndex

t11NsInfoSubsetSwitchIndex

Module: T11-FC-NAME-SERVER-MIB

OID (symbolic): T11-FC-NAME-SERVER-MIB::t11NsInfoSubsetSwitchIndex

OID (numeric): 1.3.6.1.2.1.135.1.1.1.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: The value of this object is zero when operations upon this Name Server Information Subset do not occur at a local Fibre Channel switch; otherwise, it is non-zero and identifies the local switch.

The switch identified by a non-zero value of this object is the same switch as is identified by the same value of fcmSwitchIndex.

What is t11NsInfoSubsetSwitchIndex?

Zero when this Name Server information subset isn't tied to a local Fibre Channel switch; otherwise a non-zero value identifying that local switch (matching fcmSwitchIndex in the FC-MGMT-MIB). Lets an admin correlate name-server data with the specific switch instance it came from in a multi-switch fabric.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.135.1.1.1.1.2
snmpwalk -v2c -c public <target> T11-FC-NAME-SERVER-MIB::t11NsInfoSubsetSwitchIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.135.1.1.1.1.2.1
snmpget -v2c -c public <target> T11-FC-NAME-SERVER-MIB::t11NsInfoSubsetSwitchIndex.1

Start monitoring Fibre Channel fabric switching equipment, Name Server FC-GS-4 (registered node/port identity status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the T11-FC-NAME-SERVER-MIB::t11NsInfoSubsetSwitchIndex OID value, configure state conditions and alerts, and monitor any Fibre Channel fabric switching equipment, Name Server FC-GS-4 (registered node/port identity status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.135t11FcNameServerMIBT11-FC-NAME-SERVER-MIB
1.3.6.1.2.1.135.1t11NsMIBObjectsT11-FC-NAME-SERVER-MIB
1.3.6.1.2.1.135.1.1t11NsStatusT11-FC-NAME-SERVER-MIB
1.3.6.1.2.1.135.1.1.1t11NsInfoSubsetTableT11-FC-NAME-SERVER-MIB
1.3.6.1.2.1.135.1.1.1.1t11NsInfoSubsetEntryT11-FC-NAME-SERVER-MIB
1.3.6.1.2.1.135.1.1.1.1.2t11NsInfoSubsetSwitchIndexT11-FC-NAME-SERVER-MIB