SWITCH-RATELIMIT-MIB :: rcRateLimitVlanPortHistoryHistoryIntervalStart

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SWITCH-RATELIMIT-MIB › rcRateLimitVlanPortHistoryHistoryIntervalStart

rcRateLimitVlanPortHistoryHistoryIntervalStart

Module: SWITCH-RATELIMIT-MIB

OID (symbolic): SWITCH-RATELIMIT-MIB::rcRateLimitVlanPortHistoryHistoryIntervalStart

OID (numeric): 1.3.6.1.4.1.8886.6.1.2.8.1.4

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first sample of the history at a time such that when the next hour of the day begins, a sample is started at that instant. Note that following this rule may require the probe to delay collecting the first sample of the history, as each sample must be of the same interval. Also note that the sample which is currently being collected is not accessible in this table until the end of its interval.

What is rcRateLimitVlanPortHistoryHistoryIntervalStart?

Read-only TimeTicks giving sysUpTime at the start of the interval this sample was collected over. It timestamps each historical sample so an admin can plot traffic counts against actual time rather than just sample order.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.2.8.1.4
snmpwalk -v2c -c public <target> SWITCH-RATELIMIT-MIB::rcRateLimitVlanPortHistoryHistoryIntervalStart

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.2.8.1.4.1
snmpget -v2c -c public <target> SWITCH-RATELIMIT-MIB::rcRateLimitVlanPortHistoryHistoryIntervalStart.1

Start monitoring Raisecom carrier-access/aggregation switch (per-port ingress/egress rate-limit status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SWITCH-RATELIMIT-MIB::rcRateLimitVlanPortHistoryHistoryIntervalStart OID value, configure state conditions and alerts, and monitor any Raisecom carrier-access/aggregation switch (per-port ingress/egress rate-limit status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8886raisecomRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6iscomSeriesRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6.1iscomSwitchRAISECOM-BASE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8886.6.1.2rcRateLimitSWITCH-RATELIMIT-MIB
1.3.6.1.4.1.8886.6.1.2.8rcRateLimitVlanPortHistoryTableSWITCH-RATELIMIT-MIB
1.3.6.1.4.1.8886.6.1.2.8.1rcRateLimitVlanPortHistoryEntrySWITCH-RATELIMIT-MIB
1.3.6.1.4.1.8886.6.1.2.8.1.4rcRateLimitVlanPortHistoryHistoryIntervalStartSWITCH-RATELIMIT-MIB