SONUS-SONET-MIB :: sonusSonetFarEndLineFailureIntervalFCs

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SONUS-SONET-MIB › sonusSonetFarEndLineFailureIntervalFCs

sonusSonetFarEndLineFailureIntervalFCs

Module: SONUS-SONET-MIB

OID (symbolic): SONUS-SONET-MIB::sonusSonetFarEndLineFailureIntervalFCs

OID (numeric): 1.3.6.1.4.1.2879.2.4.3.1.3.9.1.3

Node type: OBJECT-TYPE

Type: PerfCurrentCount

Access: read-only

Description: The counter associated with the number of Failures encountered by a SONET/SDH Line in the current 15 minute interval.

What is sonusSonetFarEndLineFailureIntervalFCs?

Count of far-end-reported Line-layer failure events for one specific historical 15-minute interval (1 = most recently completed of up to 32); like its near-end counterpart, this is a past interval despite the source description text mirroring the 'current' wording.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2879.2.4.3.1.3.9.1.3
snmpwalk -v2c -c public <target> SONUS-SONET-MIB::sonusSonetFarEndLineFailureIntervalFCs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2879.2.4.3.1.3.9.1.3.1
snmpget -v2c -c public <target> SONUS-SONET-MIB::sonusSonetFarEndLineFailureIntervalFCs.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sonusSonetFarEndLineFailureIntervalFCs.1

Start monitoring Sonus Networks softswitch platform with SONET/SDH transport (per-port SONET alarm/admin status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SONUS-SONET-MIB::sonusSonetFarEndLineFailureIntervalFCs OID value, configure state conditions and alerts, and monitor any Sonus Networks softswitch platform with SONET/SDH transport (per-port SONET alarm/admin status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2879sonusSONUS-SMI
1.3.6.1.4.1.2879.2sonusMgmtSONUS-SMI
1.3.6.1.4.1.2879.2.4sonusCircuitMIBsSONUS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2879.2.4.3sonusSonetMIBSONUS-SONET-MIB
1.3.6.1.4.1.2879.2.4.3.1sonusSonetObjectsSONUS-SONET-MIB
1.3.6.1.4.1.2879.2.4.3.1.3sonusSonetLineSONUS-SONET-MIB
1.3.6.1.4.1.2879.2.4.3.1.3.9sonusSonetFarEndLineFailureIntervalTableSONUS-SONET-MIB
1.3.6.1.4.1.2879.2.4.3.1.3.9.1sonusSonetFarEndLineFailureIntervalEntrySONUS-SONET-MIB
1.3.6.1.4.1.2879.2.4.3.1.3.9.1.3sonusSonetFarEndLineFailureIntervalFCsSONUS-SONET-MIB