SLA-MONITOR-MIB :: slaMonitorRtpCtrlTargetAddress

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SLA-MONITOR-MIB › slaMonitorRtpCtrlTargetAddress

slaMonitorRtpCtrlTargetAddress

Module: SLA-MONITOR-MIB

OID (symbolic): SLA-MONITOR-MIB::slaMonitorRtpCtrlTargetAddress

OID (numeric): 1.3.6.1.4.1.45.4.8.1.2.4.1.4

Node type: OBJECT-TYPE

Type: InetAddress

Access: read-create

Description: Specifies the target address used for the RTP test. The address type can be determined by examining the value of the corresponding slaMonitorRtpCtrlTargetAddressType.

A value for this object MUST be provided during entry creation.

What is slaMonitorRtpCtrlTargetAddress?

This read-create value sets the destination address the RTP performance test should target, and must be supplied when the row is created since there is no default. An admin validating voice quality to a remote site would point this at an SLA Monitor agent or endpoint at that site.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.45synopticsCMU-MIB
1.3.6.1.4.1.45.4policySYNOPTICS-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.45.4.8slaMonitorMibSLA-MONITOR-MIB
1.3.6.1.4.1.45.4.8.1slaMonitorMibClassesSLA-MONITOR-MIB
1.3.6.1.4.1.45.4.8.1.2slaMonitorAgtTestClassesSLA-MONITOR-MIB
1.3.6.1.4.1.45.4.8.1.2.4slaMonitorRtpCtrlTableSLA-MONITOR-MIB
1.3.6.1.4.1.45.4.8.1.2.4.1slaMonitorRtpCtrlEntrySLA-MONITOR-MIB
1.3.6.1.4.1.45.4.8.1.2.4.1.4slaMonitorRtpCtrlTargetAddressSLA-MONITOR-MIB