SL-OPT-APS-MIB :: optApsConfigSwitchReason

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SL-OPT-APS-MIB › optApsConfigSwitchReason

optApsConfigSwitchReason

Module: SL-OPT-APS-MIB

OID (symbolic): SL-OPT-APS-MIB::optApsConfigSwitchReason

OID (numeric): 1.3.6.1.4.1.4515.1.11.1.1.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The reason why APS switch happened. When the working connection on one end fails, its other end is told to do an APS switch. The following options in the increasing order of priority indicate what type of switch request it is.

optApsRevertive : Switch back to working connection after the Wait-to-Restore interval is over, and failures are cleared. It is the lowest priority. optApsManual : Manual switch causes APS switch unless a request of equal or higher priority is in effect. optApsSignalFailureHigh : switch occured due to SD failure. optApsForceSwitch : Forced switch forces hardware to switch the active connection even if the other connection (could be working connection or protection connection) is in alarm. optApsLockOut : This is the highest priority switch. This will override all other requests. optApsLockOut : indicates that the last switchover to the working occurred because of protection lockout.

What is optApsConfigSwitchReason?

Read-only enumeration reporting why the last APS switch on this channel occurred, in increasing priority order: optApsRevertive (lowest, automatic switch-back), optApsManual, optApsSignalFailure, optApsForceSwitch, up to optApsLockOut (highest, a protection lockout in effect). Check this after an unexpected switchover to see whether it was operator-driven or fault-driven.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.11.1.1.1.18
snmpwalk -v2c -c public <target> SL-OPT-APS-MIB::optApsConfigSwitchReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.11.1.1.1.18.1
snmpget -v2c -c public <target> SL-OPT-APS-MIB::optApsConfigSwitchReason.1

Start monitoring Smartoptics SiteLight optical transport platform (optical Automatic Protection Switching status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-OPT-APS-MIB::optApsConfigSwitchReason OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transport platform (optical Automatic Protection Switching status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.11slOptApsMibSL-OPT-APS-MIB
1.3.6.1.4.1.4515.1.11.1slOptApsConfigSL-OPT-APS-MIB
1.3.6.1.4.1.4515.1.11.1.1optApsConfigTableSL-OPT-APS-MIB
1.3.6.1.4.1.4515.1.11.1.1.1optApsConfigEntrySL-OPT-APS-MIB
1.3.6.1.4.1.4515.1.11.1.1.1.18optApsConfigSwitchReasonSL-OPT-APS-MIB