SL-MAIN-MIB :: slmSysTemperature

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › SL-MAIN-MIB › slmSysTemperature

slmSysTemperature

Module: SL-MAIN-MIB

OID (symbolic): SL-MAIN-MIB::slmSysTemperature

OID (numeric): 1.3.6.1.4.1.4515.1.3.1.43

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The temperature of the PL device in Celsius.

What is slmSysTemperature?

This object reports the current internal temperature of a PacketLogic/Sandvine device in degrees Celsius, providing thermal health monitoring. System administrators monitor this to ensure the device stays within safe operating temperature ranges and to detect cooling system failures. Elevated temperatures may trigger throttling or shutdown mechanisms.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.3.1.43
snmpwalk -v2c -c public <target> SL-MAIN-MIB::slmSysTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.3.1.43.1
snmpget -v2c -c public <target> SL-MAIN-MIB::slmSysTemperature.1

Start monitoring SmartOptics SiteLight optical transport main control card/chassis (system/alarm/software-version status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-MAIN-MIB::slmSysTemperature OID value, configure state conditions and alerts, and monitor any SmartOptics SiteLight optical transport main control card/chassis (system/alarm/software-version status) from a single console.

How to Use in IPNetwork Monitor

Select a SmartOptics SiteLight optical transport main control card or chassis as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type slmSysTemperature into the Find box to locate it in the OID tree, then select it and click OK. It reports the current temperature of the PL device, in degrees Celsius. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.3slMainSL-MAIN-MIB
1.3.6.1.4.1.4515.1.3.1slmSysSL-MAIN-MIB
1.3.6.1.4.1.4515.1.3.1.43slmSysTemperatureSL-MAIN-MIB