All MIBs › SL-DRY-CON-MIB › slDryConOutCommand
slDryConOutCommand
Module: SL-DRY-CON-MIB
OID (symbolic): SL-DRY-CON-MIB::slDryConOutCommand
OID (numeric): 1.3.6.1.4.1.4515.1.7.1.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Setting this object controls the output dry contact state: activate(1) - activate the output dry contact deactivate(2) - dectivate the output dry contact clear(3) - clears the output dry contact command The object value can also be read by the management. In this case the agent should return the current command to the management. The object value should not be kept in the NVRAM because it is used only for testing. The intial value should be clear(3).
What is slDryConOutCommand?
This read-write INTEGER controls the state of an output dry contact, with values activate(1) to close/activate the contact, deactivate(2) to open/deactivate it, and clear(3) to clear the command, and its initial value is clear(3). An admin uses it to remotely drive an external relay-controlled device, such as a bell or light, and can also read it back since the agent reflects the current command rather than persisting it in NVRAM, as it is intended only for testing. For example, an admin would set this to activate(1) to momentarily energize a connected alarm bell, then set it back to clear(3) afterward.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.7.1.2.1.2 snmpwalk -v2c -c public <target> SL-DRY-CON-MIB::slDryConOutCommand
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.7.1.2.1.2.1 snmpget -v2c -c public <target> SL-DRY-CON-MIB::slDryConOutCommand.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4515.1.7.1.2.1.2.1 i <value>
Start monitoring Smartoptics SiteLight optical transport equipment, dry-contact I/O interface (external alarm input/output status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-DRY-CON-MIB::slDryConOutCommand OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transport equipment, dry-contact I/O interface (external alarm input/output status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4515 | smartoptics | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1 | sitelight | SL-NE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4515.1.7 | slDryConMib | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.1 | slDryConOut | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.1.2 | slDryConOutTable | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.1.2.1 | slDryConOutEntry | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.1.2.1.2 | slDryConOutCommand | SL-DRY-CON-MIB |