All MIBs › SL-DRY-CON-MIB › slDryConInDescription
slDryConInDescription
Module: SL-DRY-CON-MIB
OID (symbolic): SL-DRY-CON-MIB::slDryConInDescription
OID (numeric): 1.3.6.1.4.1.4515.1.7.2.2.1.2
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: A textual description of the input dry contact alarm.
What is slDryConInDescription?
This read-write DisplayString (0-40 characters) holds a free-text description of what the input dry contact alarm represents, per the GR-833-CORE Appendix L alarm message format. An admin sets this so that when the alarm fires, the description clearly identifies the physical condition being monitored rather than just a numeric index. For example, an admin might set this to "Equipment Room Door Open" to label the alarm generated by a door-open sensor wired to that input.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.7.2.2.1.2 snmpwalk -v2c -c public <target> SL-DRY-CON-MIB::slDryConInDescription
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.7.2.2.1.2.1 snmpget -v2c -c public <target> SL-DRY-CON-MIB::slDryConInDescription.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4515.1.7.2.2.1.2.1 s <value>
Start monitoring Smartoptics SiteLight optical transport equipment, dry-contact I/O interface (external alarm input/output status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-DRY-CON-MIB::slDryConInDescription OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transport equipment, dry-contact I/O interface (external alarm input/output status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4515 | smartoptics | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1 | sitelight | SL-NE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4515.1.7 | slDryConMib | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2 | slDryConIn | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2.2 | slDryConInTable | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2.2.1 | slDryConInEntry | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2.2.1.2 | slDryConInDescription | SL-DRY-CON-MIB |