All MIBs › SL-DRY-CON-MIB › slDryConInAlmType
slDryConInAlmType
Module: SL-DRY-CON-MIB
OID (symbolic): SL-DRY-CON-MIB::slDryConInAlmType
OID (numeric): 1.3.6.1.4.1.4515.1.7.2.2.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Describe the current input dry contact alarm type.
What is slDryConInAlmType?
This read-write INTEGER, defined per GR-833-CORE Appendix F Table 1, classifies the type of environmental or equipment alarm condition monitored by an input dry contact, with enumerated values such as fire(13), flood(14), hitemp(19), power(31), and smoke(36). An admin sets this so alarm systems and NMS displays can categorize what physical condition triggered the input, rather than showing a generic contact number. For example, an admin would set this to smoke(36) for an input wired to a smoke detector, or power(31) for one monitoring loss of commercial AC power.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.7.2.2.1.7 snmpwalk -v2c -c public <target> SL-DRY-CON-MIB::slDryConInAlmType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.7.2.2.1.7.1 snmpget -v2c -c public <target> SL-DRY-CON-MIB::slDryConInAlmType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4515.1.7.2.2.1.7.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> slDryConInAlmType.1
Start monitoring Smartoptics SiteLight optical transport equipment, dry-contact I/O interface (external alarm input/output status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-DRY-CON-MIB::slDryConInAlmType OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transport equipment, dry-contact I/O interface (external alarm input/output status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4515 | smartoptics | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1 | sitelight | SL-NE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4515.1.7 | slDryConMib | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2 | slDryConIn | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2.2 | slDryConInTable | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2.2.1 | slDryConInEntry | SL-DRY-CON-MIB |
| 1.3.6.1.4.1.4515.1.7.2.2.1.7 | slDryConInAlmType | SL-DRY-CON-MIB |