All MIBs › SIEMENS-HP4KHIM-MIB
Organization: Siemens
Last Updated: 2006-11-10
Category: Siemens Enterprise
Description: Manages Siemens HP4K host interface module configuration, port status, and data path state.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is SIEMENS-HP4KHIM-MIB?
SIEMENS-HP4KHIM-MIB is a Siemens enterprise MIB for the HiPath 4000 (HP4K) telephony platform's Host Interface Module (HIM), covering hardware architecture identification, software version/release tracking, and welcome-page/PABX (private branch exchange) identification data. It exposes objects reporting hardware architecture type, system release and revision level, HIM version, and PABX system numbers, alongside a 'welcome page' table used for system identification during login/administration. Its monitoring emphasis is squarely on software version and hardware architecture status: confirming which HP4K system release, revision level, and hardware architecture a given HIM is running, which is essential for compatibility checks before applying patches or interoperating with other PBX nodes. It is a self-contained Siemens enterprise MIB without evident dependency on external standard MIBs. It is deployed in enterprise/carrier telephony environments running Siemens HiPath 4000 PBX systems where the HIM component bridges host management functions to the switching fabric, and a SIEMENS-HP4KHIM-MIB download from Siemens/Unify support lets administrators load it into a MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SIEMENS-HP4KHIM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Siemens HiPath 4000 (HP4K) PBX host interface module
Monitoring Examples
An administrator would poll himHP4KVersion, himSystemRelease, and himRevisionLevel together to confirm the exact software build running on a HIM before applying a firmware update, and check himHWArchitecture/himHWArchitectureType to ensure the update package is compatible with the installed hardware generation. Reading himWelPgTable entries such as himWelPgPabxId and himWelPgSysNo confirms which PABX and system number the HIM belongs to, which matters when managing a multi-node HiPath cluster where mismatched release levels between nodes can cause interoperability issues.
What Can Be Monitored
- HIM hardware architecture type
- system release version
- revision level
- PABX identifier
- system number
- operation mode
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-CONF
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 | |
| enterprises |
From SNMPv2-TC
| DisplayString | |
| MacAddress | |
| TEXTUAL-CONVENTION |
How to Use in IPNetwork Monitor
Example using himChanges OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| siemens | 1.3.6.1.4.1.4329 | |||
| iandcAdmin | 1.3.6.1.4.1.4329.2 | |||
| hp4khim | 1.3.6.1.4.1.4329.2.51 | |||
| himWelcomePage | 1.3.6.1.4.1.4329.2.51.1 | |||
| himWelPgTable | 1.3.6.1.4.1.4329.2.51.1.1 | not-accessible | ||
| himWelPgEntry | 1.3.6.1.4.1.4329.2.51.1.1.1 | not-accessible | ||
| HIM himWelPgPabxId | 1.3.6.1.4.1.4329.2.51.1.1.1.1 | HimPabxId | read-only | |
| HIM himWelPgSysNo | 1.3.6.1.4.1.4329.2.51.1.1.1.2 | HimSwitchNumber | read-only | This field contains the system number (max. 17 characters). |
| OCT himHP4KVersion | 1.3.6.1.4.1.4329.2.51.1.1.1.3 | OCTET STRING | read-only | This field contains the Hicom/HiPath version number of the system (max. 4 characters). |
| OCT himSystemRelease | 1.3.6.1.4.1.4329.2.51.1.1.1.4 | OCTET STRING | read-only | This field contains the system release number of the system (max. 2 characters). |
| OCT himRevisionLevel | 1.3.6.1.4.1.4329.2.51.1.1.1.5 | OCTET STRING | read-only | This field contains the revision number of the system software (max. 2 characters). |
| OCT himHWArchitecture | 1.3.6.1.4.1.4329.2.51.1.1.1.6 | OCTET STRING | read-only | This field contains the information on hardware architecture in the format [hw-architecture][system-variant][hw-design] [hw-architecture] Abbreviation describing hardware architecture. F.i '4300', '350E', etc. [system-variant] H40: SYSTEM VARIANT 40 H80: SYSTEM VARIANT 80 H600: SYSTEM VARIANT 600 [hw-design] ECX: HARDWARE DESIGN EXTENDED COMPACT EXTENDED ECDSC: HARDWARE DESIGN EXTENDED COMPACT DSC CXE: HARDWARE DESIGN EXTENDED COMPACT CXE |
| OCT himHWArchitectureType | 1.3.6.1.4.1.4329.2.51.1.1.1.7 | OCTET STRING | read-only | This field contains abbreviation describing hardware architecture type (max. 3 characters). |
| OCT himOperationMode | 1.3.6.1.4.1.4329.2.51.1.1.1.8 | OCTET STRING | read-only | This field contains the operating mode of the system. Possible Values: SIMPLEX: OPERATING MODE SIMPLEX DUPLEX: OPERATING MODE DUPLEX REDUNDANCY |
| OCT himSWUProc1 | 1.3.6.1.4.1.4329.2.51.1.1.1.9 | OCTET STRING | read-only | These fields contains the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B |
| OCT himSWUMemory1 | 1.3.6.1.4.1.4329.2.51.1.1.1.10 | OCTET STRING | read-only | These fields contain the size of the SWU memory for each processor card. SWU = Switching Unit |
| OCT himSWUProc2 | 1.3.6.1.4.1.4329.2.51.1.1.1.11 | OCTET STRING | read-only | These fields contains the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B |
| OCT himSWUMemory2 | 1.3.6.1.4.1.4329.2.51.1.1.1.12 | OCTET STRING | read-only | These fields contain the size of the SWU memory for each processor card. SWU = Switching Unit |
| himSwitchData | 1.3.6.1.4.1.4329.2.51.2 | |||
| himTechInfoTable | 1.3.6.1.4.1.4329.2.51.2.1 | not-accessible | ||
| himTechInfoEntry | 1.3.6.1.4.1.4329.2.51.2.1.1 | not-accessible | ||
| HIM himTechInfoPabxId | 1.3.6.1.4.1.4329.2.51.2.1.1.1 | HimPabxId | read-only | |
| OCT himTechInfoInfoNo | 1.3.6.1.4.1.4329.2.51.2.1.1.2 | OCTET STRING | read-only | This field contains the number of the subsystem. This number can be assigned as required when configuring the subsystem. |
| OCT himTechInfoDate | 1.3.6.1.4.1.4329.2.51.2.1.1.3 | OCTET STRING | read-only | This field contains the date on which the subsystem was configured. |
| OCT himTechInfoTechnicalData | 1.3.6.1.4.1.4329.2.51.2.1.1.4 | OCTET STRING | read-only | This field contains the technical data of the subsystem. |
| OCT himTechInfoNumber | 1.3.6.1.4.1.4329.2.51.2.1.1.5 | OCTET STRING | read-only | This field contains the number of each subsystem configured. |
| OCT himTechInfoExtraText | 1.3.6.1.4.1.4329.2.51.2.1.1.6 | OCTET STRING | read-only | This field contains additional text. |
| himNotepadDataTable | 1.3.6.1.4.1.4329.2.51.2.2 | not-accessible | This node contains the system data entered in a notepad. The table for notepad entries holds a maximum of 30 data records. | |
| himNotepadDataEntry | 1.3.6.1.4.1.4329.2.51.2.2.1 | not-accessible | ||
| HIM himNotepadDataPabxId | 1.3.6.1.4.1.4329.2.51.2.2.1.1 | HimPabxId | read-only | |
| U32 himNotepadDataInfoNo | 1.3.6.1.4.1.4329.2.51.2.2.1.2 | Unsigned32 | read-only | This field contains the number of the subsystem. This number is assigned permanently when configuring the subsystem. |
| OCT himNotepadDataDate | 1.3.6.1.4.1.4329.2.51.2.2.1.3 | OCTET STRING | read-only | This field contains the date on which the subsystem was configured. |
| OCT himNotepadDataText | 1.3.6.1.4.1.4329.2.51.2.2.1.4 | OCTET STRING | read-only | This field contains the technical data of the subsystem. |
| himProjPlanInfoTable | 1.3.6.1.4.1.4329.2.51.2.3 | not-accessible | This screen makes it possible to generate a file with project planning data. | |
| himProjPlanInfoEntry | 1.3.6.1.4.1.4329.2.51.2.3.1 | not-accessible | ||
| HIM himProjPlanPabxId | 1.3.6.1.4.1.4329.2.51.2.3.1.1 | HimPabxId | read-only | |
| OCT himProjPlanInfoFile | 1.3.6.1.4.1.4329.2.51.2.3.1.2 | OCTET STRING | read-only | This field contains the name of the project planning file. |
| OCT himProjPlanInfoCreationDate | 1.3.6.1.4.1.4329.2.51.2.3.1.3 | OCTET STRING | read-only | This field contains the date on which the project planning file was generated. |
| OCT himProjPlanInfoCreationTime | 1.3.6.1.4.1.4329.2.51.2.3.1.4 | OCTET STRING | read-only | This field contains the time at which the project planning file was generated. |
| himSpecSwitchData | 1.3.6.1.4.1.4329.2.51.3 | |||
| himSpecShelfDataTable | 1.3.6.1.4.1.4329.2.51.3.1 | not-accessible | All subscriber and trunk-related lines are grouped within LTU (Line/Trunk Unit) frames. Each frame has several slots for modules. The frame is connected to the system via the LTUC control board. This table contains the frame configuration. | |
| himSpecShelfDataEntry | 1.3.6.1.4.1.4329.2.51.3.1.1 | not-accessible | ||
| HIM himSpecShelfDataPabxId | 1.3.6.1.4.1.4329.2.51.3.1.1.1 | HimPabxId | read-only | |
| OCT himSpecShelfDataAddress | 1.3.6.1.4.1.4329.2.51.3.1.1.2 | OCTET STRING | read-only | This field contains the address of the shelf in format LTG.LTU. LTG:Line/Trunk Group LTU: Line/Trunk Unit |
| OCT himSpecShelfDataFrameType | 1.3.6.1.4.1.4329.2.51.3.1.1.3 | OCTET STRING | read-only | This field contains the part number of the frame. |
| INT himSpecShelfDataLTU | 1.3.6.1.4.1.4329.2.51.3.1.1.4 | INTEGER | read-only | This field contains type of LTU (Line/Trunk Unit) frame. Possible values for LTU frame type: - PREATL - frametype for Preatlantic Hicom Types - CC40F - basisframe for 40CMX - CC80W - basisframe for 80CMX - CC80F - basisframe for 80CMX/DSC and CXE - L80XF - for 80CMX/DSC, CXE, 600ECS and AP shelves - L80XW - extension frame for 80CMX/DSC - LTUW - frame for 600ECX and AP shelves Possible values for AP shelf type: - L80XF - for 80CMX/DSC, CXE, 600ECS and AP shelves - LTUW - frame for 600ECX and AP shelves - INCH19 - 19 inch frame for AP shelves |
| HIM himSpecShelfDataNetworkType | 1.3.6.1.4.1.4329.2.51.3.1.1.5 | HimShelfNWType | read-only | This field contains connection type of LTU frame / AP shelf. |
| IP himSpecShelfDataNetworkAddress | 1.3.6.1.4.1.4329.2.51.3.1.1.6 | IpAddress | read-only | This field contains network IP address. |
| OCT himSpecShelfDataRemote | 1.3.6.1.4.1.4329.2.51.3.1.1.7 | OCTET STRING | read-only | This field shows if frame is remote. Possible values: - yes - frame is remote - no - frame is not remote |
| OCT himSpecShelfDataLocation | 1.3.6.1.4.1.4329.2.51.3.1.1.8 | OCTET STRING | read-only | This field contains postal address (city, street, building, ..) , where a FLEX LTU or an AP shelf is located. |
| OCT himSpecShelfDataLTUC | 1.3.6.1.4.1.4329.2.51.3.1.1.9 | OCTET STRING | read-only | This field contains part number adding LTUC module. LTUC: Line/Trunk Unit Control. |
| himSWUBoardTable | 1.3.6.1.4.1.4329.2.51.3.2 | not-accessible | This table contains the configuration of the peripheral boards. Periphery Assemblies Peripheral and ring generator assemblies as well as SIU are configured in the LTU. The board is entered in the SWU database. LTU = Line/Trunk Unit SIU = Signaling Interface Unit SWU = Switching Unit | |
| himSWUBoardEntry | 1.3.6.1.4.1.4329.2.51.3.2.1 | not-accessible | ||
| HIM himSWUBoardPabxId | 1.3.6.1.4.1.4329.2.51.3.2.1.1 | HimPabxId | read-only | |
| HIM himSWUBoardPEN | 1.3.6.1.4.1.4329.2.51.3.2.1.2 | HimPEN | read-only | This field contains the name of the board PEN. PEN: Port Equipment Number The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group LTU: Line/Trunk Unit EBT: Slot |
| OCT himSWUBoardOverlayLTU | 1.3.6.1.4.1.4329.2.51.3.2.1.3 | OCTET STRING | read-only | This field contains the name of the overlay LTU (Line/Trunk Unit). |
| OCT himSWUBoardType | 1.3.6.1.4.1.4329.2.51.3.2.1.4 | OCTET STRING | read-only | This field contains the name of the configured board. |
| OCT himSWUBoardNominal | 1.3.6.1.4.1.4329.2.51.3.2.1.5 | OCTET STRING | read-only | This field contains the name of the nominal board. |
| OCT himSWUBoardActual | 1.3.6.1.4.1.4329.2.51.3.2.1.6 | OCTET STRING | read-only | This field contains part number of the board that is plugged in. |
| OCT hhimSWUBoardFirmware | 1.3.6.1.4.1.4329.2.51.3.2.1.7 | OCTET STRING | read-only | This field contains the name of the firmware. |
| OCT himSWUBoardRev | 1.3.6.1.4.1.4329.2.51.3.2.1.8 | OCTET STRING | read-only | This field contains the revision of the board. |
| OCT himSWUBoardFunctId | 1.3.6.1.4.1.4329.2.51.3.2.1.9 | OCTET STRING | read-only | Function identification number for boards with more than one functions (e.g. SIUX, STMA, SLMO24). |
| OCT himSWUBoardMode | 1.3.6.1.4.1.4329.2.51.3.2.1.10 | OCTET STRING | read-only | This field contains the mode of the board. The mode is only displayed for the RG/ACGEN board. |
| OCT himSWUBoardLWNo | 1.3.6.1.4.1.4329.2.51.3.2.1.11 | OCTET STRING | read-only | This field contains the number of the loadware. |
| OCT himSWUBoardLWInterVer | 1.3.6.1.4.1.4329.2.51.3.2.1.12 | OCTET STRING | read-only | This field contains the interface version of the board. |
| OCT himSWUBoardLWName | 1.3.6.1.4.1.4329.2.51.3.2.1.13 | OCTET STRING | read-only | This field contains the file name of the loadware file or of the initialization file. |
| OCT himSWUBoardLWDate | 1.3.6.1.4.1.4329.2.51.3.2.1.14 | OCTET STRING | read-only | This field contains the date on which the loadware or the initialization file was generated. |
| himSWUPeriphery | 1.3.6.1.4.1.4329.2.51.4 | |||
| himPSIOAssTable | 1.3.6.1.4.1.4329.2.51.4.1 | not-accessible | This table contains the PSIO assemblies data. | |
| himPSIOAssEntry | 1.3.6.1.4.1.4329.2.51.4.1.1 | not-accessible | ||
| HIM himPSIOAssPabxId | 1.3.6.1.4.1.4329.2.51.4.1.1.1 | HimPabxId | read-only | |
| HIM himPSIOAssPEN | 1.3.6.1.4.1.4329.2.51.4.1.1.2 | HimPEN | read-only | This field contains the name of the board PEN. PEN: Port Equipment Number The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group LTU: Line/Trunk Unit EBT: Slot |
| OCT himPSIOAssAssembly | 1.3.6.1.4.1.4329.2.51.4.1.1.3 | OCTET STRING | read-only | This field contains the name of the PSIO board. PSIO: Peripheral Serial Input Output |
| OCT himPSIOAssActual | 1.3.6.1.4.1.4329.2.51.4.1.1.4 | OCTET STRING | read-only | This field contains the part number of the PSIO board. |
| OCT himPSIOAssFirmware | 1.3.6.1.4.1.4329.2.51.4.1.1.5 | OCTET STRING | read-only | This field contains the firmware name of the PSIO board. |
| himSerialLineTable | 1.3.6.1.4.1.4329.2.51.4.2 | not-accessible | This table contains the serial interfaces data. | |
| himSerialLineEntry | 1.3.6.1.4.1.4329.2.51.4.2.1 | not-accessible | ||
| HIM himSerialLinePabxId | 1.3.6.1.4.1.4329.2.51.4.2.1.1 | HimPabxId | read-only | |
| U32 himSerialLineNumber | 1.3.6.1.4.1.4329.2.51.4.2.1.2 | Unsigned32 | read-only | This field contains the physical line number of the interface. Possible Values: numeric, 8-63 |
| OCT himSerialLineBoardType | 1.3.6.1.4.1.4329.2.51.4.2.1.3 | OCTET STRING | read-only | This field contains abbreviation name of the board type. |
| U32 himSerialLineSpeed | 1.3.6.1.4.1.4329.2.51.4.2.1.4 | Unsigned32 | read-only | This field contains standardized transmission speed (baud rate). Possible Values: 50, 100, 200, 300, 600, 1200, 2400, 4800, 9600, 19200. |
| OCT himSerialLineLogDevName | 1.3.6.1.4.1.4329.2.51.4.2.1.5 | OCTET STRING | read-only | This field contains the logical device name of the line. Possible Values: Value - Description CON1 - LOGICAL DEVICE CONNECTION,TERMINAL 1 CON2 - LOGICAL DEVICE CONNECTION,TERMINAL 2 CON3 - LOGICAL DEVICE CONNECTION,TERMINAL 3 CON4 - LOGICAL DEVICE CONNECTION,TERMINAL 4 CON5 - LOGICAL DEVICE CONNECTION 5 CON6 - LOGICAL DEVICE CONNECTION 6 PR1 - LOGICAL DEVICE:LINE PRINTER 1 PR2 - LOGICAL DEVICE:LINE PRINTER 2 PR3 - LOGICAL DEVICE:LINE PRINTER 3 PR4 - LOGICAL DEVICE:LINE PRINTER 4 |
| OCT himSerialLineDevType | 1.3.6.1.4.1.4329.2.51.4.2.1.6 | OCTET STRING | read-only | This field contains the device type of the line. Possible Values: Value - Description PT88 - DEVICE TYPE QUOSC - QUME-ONLY-SCREEN QUOPT - QUME-ONLY-PT88 QUSCAPT - QUME-SCREEN-AND-PT88 PCOSC - PC-D-ONLY-SCREEN PCOPT - PC-D-ONLY-PT88 PCSCAPT - PC-D-SCREEN-AND-PT88 ASC - ASCII-CODE EBC - EBCDIC CODE RSV1 - RESERVED DEVICE TYPE 1 RSV2 - RESERVED DEVICE TYPE 2 RSV3 - RESERVED DEVICE TYPE 3 |
| INT himSerialLineType | 1.3.6.1.4.1.4329.2.51.4.2.1.7 | INTEGER | read-only | This field contains the line type (operation of synchronous lines (terminals) connected via V24 modems). Possible values: - ASY: asynchronous line type - V24: ccitt rec v24 |
| himSCSIDevTable | 1.3.6.1.4.1.4329.2.51.4.3 | not-accessible | This table contains the data for the SCSI devices connected. | |
| himSCSIDevEntry | 1.3.6.1.4.1.4329.2.51.4.3.1 | not-accessible | ||
| HIM himSCSIDevPabxId | 1.3.6.1.4.1.4329.2.51.4.3.1.1 | HimPabxId | read-only | |
| U32 himSCSIDevId | 1.3.6.1.4.1.4329.2.51.4.3.1.2 | Unsigned32 | read-only | This field contains the type of SCSI device. |
| OCT himSCSIDevType | 1.3.6.1.4.1.4329.2.51.4.3.1.3 | OCTET STRING | read-only | This field contains the SCSI ID of the device. |
| OCT himSCSIDevName | 1.3.6.1.4.1.4329.2.51.4.3.1.4 | OCTET STRING | read-only | This field contains the name of the SCSI device in format: [vendor] [product number]. |
| OCT himSCSIDevFirmware | 1.3.6.1.4.1.4329.2.51.4.3.1.5 | OCTET STRING | read-only | This field contains the firmware name of the SCSI device. |
| OCT himSCSIDevLoadDrive | 1.3.6.1.4.1.4329.2.51.4.3.1.6 | OCTET STRING | read-only | This field displays (if activity is in progress) the device from which the operating system and the database are started. |
| himCentralSwitchData | 1.3.6.1.4.1.4329.2.51.5 | |||
| himCabinetTable | 1.3.6.1.4.1.4329.2.51.5.1 | not-accessible | This table contains the data for configuring the cabinets and frames in a system. They reflect the physical structure of the system. | |
| himCabinetEntry | 1.3.6.1.4.1.4329.2.51.5.1.1 | not-accessible | ||
| HIM himCabPabxId | 1.3.6.1.4.1.4329.2.51.5.1.1.1 | HimPabxId | read-only | |
| OCT himCabAddr | 1.3.6.1.4.1.4329.2.51.5.1.1.2 | OCTET STRING | read-only | This field contains the cabinet address. Structure of cabinet address: P 1 01 | | |__Number of cabinet in cabinet row | |_____Units, position of cabinet row |_______Tens (P=0, Q=1), position of the cabinet |
| OCT himCabPhysAddr | 1.3.6.1.4.1.4329.2.51.5.1.1.3 | OCTET STRING | read-only | |
| OCT himCabCabinet | 1.3.6.1.4.1.4329.2.51.5.1.1.4 | OCTET STRING | read-only | This field contains the name of the cabinet. |
| OCT himCabPartNo | 1.3.6.1.4.1.4329.2.51.5.1.1.5 | OCTET STRING | read-only | This field contains the part number of the cabinet. |
| U32 himCabShelfNo | 1.3.6.1.4.1.4329.2.51.5.1.1.6 | Unsigned32 | read-only | This field contains the number of the shelf. |
| OCT himCabFrame | 1.3.6.1.4.1.4329.2.51.5.1.1.7 | OCTET STRING | read-only | This field contains the name of the frame. |
| OCT himCabPid1 | 1.3.6.1.4.1.4329.2.51.5.1.1.8 | OCTET STRING | read-only | This field contains the processor ID 1. |
| OCT himCabPid2 | 1.3.6.1.4.1.4329.2.51.5.1.1.9 | OCTET STRING | read-only | This field contains the processor ID 2. |
| OCT himCabPid3 | 1.3.6.1.4.1.4329.2.51.5.1.1.10 | OCTET STRING | read-only | This field contains the processor ID 2. |
| OCT himCabLTUNo | 1.3.6.1.4.1.4329.2.51.5.1.1.11 | OCTET STRING | read-only | This field contains the number of the LTU (Line/Trunk Unit). The LTU range is divided in two parts: HHS (HICOM Host System) and AP (Access Point). The available values of the ranges are: HHS 1-15 and AP 17-99. The LTU 16 is forbidden. There are existing shelfes which are allowed only in HHS and others which are allowed only in the AP range. |
| himMemScalingTable | 1.3.6.1.4.1.4329.2.51.5.2 | not-accessible | This screen contains the memory parameters for each of the devices or features specified. The values are only displayed in Configuration Management. See also DIMSU parameter list. | |
| himMemScalingEntry | 1.3.6.1.4.1.4329.2.51.5.2.1 | not-accessible | ||
| HIM himMemScalingPabxId | 1.3.6.1.4.1.4329.2.51.5.2.1.1 | HimPabxId | read-only | |
| OCT himMemScalingUnit | 1.3.6.1.4.1.4329.2.51.5.2.1.2 | OCTET STRING | read-only | This field contains the parameter name (AMO DIMSU). |
| I32 himMemScalingUsed | 1.3.6.1.4.1.4329.2.51.5.2.1.3 | Integer32 | read-only | This value specifies the number of memory elements already used up. The comparison with the value in the Maximum field indicates how much of the allocated memory is still available for configuring devices or features. |
| I32 himMemScalingMaxUsed | 1.3.6.1.4.1.4329.2.51.5.2.1.4 | Integer32 | read-only | This field contains the number of memory elements allocated. |
| I32 himMemScalingAllocated | 1.3.6.1.4.1.4329.2.51.5.2.1.5 | Integer32 | read-only | This field displays the maximum number of memory elements that once have been used up during the lifetime of the switch ('high water mark'). It gives an indication how much memory was necessary at one time, so it is advised to not reduce the Maximum value below this value. |
| I32 himMemScalingStandard | 1.3.6.1.4.1.4329.2.51.5.2.1.6 | Integer32 | read-only | Standard is the advised value to be set in the Maximum field, if you don't have special needs to set it to a specific value. If you set all devices and features to the standard values it is guaranteed that you don't run out of DIMSU memory. |
| I32 himMemScalingSysMax | 1.3.6.1.4.1.4329.2.51.5.2.1.7 | Integer32 | read-only | This field contains the maximum number of possible memory elements. |
| himGeneralSwitchData | 1.3.6.1.4.1.4329.2.51.6 | |||
| himDBConfSys | 1.3.6.1.4.1.4329.2.51.6.1 | |||
| himDBConfSysTable | 1.3.6.1.4.1.4329.2.51.6.1.1 | not-accessible | ||
| himDBConfSysEntry | 1.3.6.1.4.1.4329.2.51.6.1.1.1 | not-accessible | ||
| HIM himDBConfSysPabxId | 1.3.6.1.4.1.4329.2.51.6.1.1.1.1 | HimPabxId | read-only | |
| OCT himDBConfSysClass1 | 1.3.6.1.4.1.4329.2.51.6.1.1.1.2 | OCTET STRING | read-only | This field contains the name of the system. |
| OCT himDBConfSysClass2 | 1.3.6.1.4.1.4329.2.51.6.1.1.1.3 | OCTET STRING | read-only | This field contains the coded name of the system. |
| OCT himDBConfSysHWAss1 | 1.3.6.1.4.1.4329.2.51.6.1.1.1.4 | OCTET STRING | read-only | This field contains the hardware ID of the system. |
| OCT himDBConfSysHWAss2 | 1.3.6.1.4.1.4329.2.51.6.1.1.1.5 | OCTET STRING | read-only | This field contains the shortened hardware ID of the system. |
| OCT himDBConfSysDevLine1 | 1.3.6.1.4.1.4329.2.51.6.1.1.1.6 | OCTET STRING | read-only | This field contains the name of the product line. |
| OCT himDBConfSysDevLine2 | 1.3.6.1.4.1.4329.2.51.6.1.1.1.7 | OCTET STRING | read-only | This field contains the shortened name of the product line. Possible values: - H300: EUROPE DEVELOPMENT - HUSA: US DEVELOPMENT |
| INT himDBConfSysOpMode | 1.3.6.1.4.1.4329.2.51.6.1.1.1.8 | INTEGER | read-only | This field contains the operating mode of the system. Possible Values: - SIMPLEX: OPERATING MODE SIMPLEX - DUPLEX: OPERATING MODE DUPLEX REDUNDANCY |
| OCT himDBConfSysResType | 1.3.6.1.4.1.4329.2.51.6.1.1.1.9 | OCTET STRING | read-only | This field contains the restart identifier. |
| OCT himDBConfSysHWArch | 1.3.6.1.4.1.4329.2.51.6.1.1.1.10 | OCTET STRING | read-only | This field contains the name of the hardware architecture. |
| OCT himDBConfSysHWArchType | 1.3.6.1.4.1.4329.2.51.6.1.1.1.11 | OCTET STRING | read-only | This field contains the name of the hardware architecture type. |
| HIM himDBConfSysNo | 1.3.6.1.4.1.4329.2.51.6.1.1.1.12 | HimSwitchNumber | read-only | This field contains the number of the system. |
| INT himDBConfSysLoc | 1.3.6.1.4.1.4329.2.51.6.1.1.1.13 | INTEGER | read-only | This field contains the name of the location in which the system is installed. Possible Values: - CUSTOMER (customer) - SUPPORT (support) - TESTLAB (testlab) |
| OCT himDBConfSysBaseApp | 1.3.6.1.4.1.4329.2.51.6.1.1.1.14 | OCTET STRING | read-only | This field contains the name of the base application. |
| OCT himDBConfSysDBApp | 1.3.6.1.4.1.4329.2.51.6.1.1.1.15 | OCTET STRING | read-only | This field contains the name of the database application. |
| OCT himDBConfSysID | 1.3.6.1.4.1.4329.2.51.6.1.1.1.16 | OCTET STRING | read-only | This field contains the system identification. |
| himDBConfHW | 1.3.6.1.4.1.4329.2.51.6.2 | |||
| himDBConfHWTable | 1.3.6.1.4.1.4329.2.51.6.2.1 | not-accessible | ||
| himDBConfHWEntry | 1.3.6.1.4.1.4329.2.51.6.2.1.1 | not-accessible | ||
| HIM himDBConfHWPabxId | 1.3.6.1.4.1.4329.2.51.6.2.1.1.1 | HimPabxId | read-only | |
| I32 himDBConfHWLTG | 1.3.6.1.4.1.4329.2.51.6.2.1.1.2 | Integer32 | read-only | This field contains the number of LTGs in the system. LTG: Line/Trunk Group |
| I32 himDBConfHWLTU | 1.3.6.1.4.1.4329.2.51.6.2.1.1.3 | Integer32 | read-only | This field contains the number of LTUs in the system. LTU: Line/Trunk Unit |
| I32 himDBConfHWLines | 1.3.6.1.4.1.4329.2.51.6.2.1.1.4 | Integer32 | read-only | This field contains the number of lines in the system. |
| I32 himDBConfHWPorts | 1.3.6.1.4.1.4329.2.51.6.2.1.1.5 | Integer32 | read-only | This field contains the number of ports in the system. |
| I32 himDBConfHWPBC | 1.3.6.1.4.1.4329.2.51.6.2.1.1.6 | Integer32 | read-only | This field contains the number of peripheral board controllers (PBC) in the system. |
| I32 himDBConfHWMTSBdPerGSN | 1.3.6.1.4.1.4329.2.51.6.2.1.1.7 | Integer32 | read-only | This field contains the number of memory time switches (MTS) per group switching network (GSN). |
| I32 himDBConfHWSIUPPerLTU | 1.3.6.1.4.1.4329.2.51.6.2.1.1.8 | Integer32 | read-only | This field contains the number of SIUP boards per LTU (Line/Trunk Unit). |
| I32 himDBConfHWDIUCPerLTU | 1.3.6.1.4.1.4329.2.51.6.2.1.1.9 | Integer32 | read-only | This field contains the number of DIUC boards per LTU (Line/Trunk Unit). |
| I32 himDBConfHWHwyPerMTSBd | 1.3.6.1.4.1.4329.2.51.6.2.1.1.10 | Integer32 | read-only | This field contains the number highways (HYW) per MTS board. |
| I32 himDBConfHWHDLCPerDCL | 1.3.6.1.4.1.4329.2.51.6.2.1.1.11 | Integer32 | read-only | This field contains the number of high level data link control (HDLC) channels per data communication link (DCL). |
| I32 himDBConfHWPBCPerDCL | 1.3.6.1.4.1.4329.2.51.6.2.1.1.12 | Integer32 | read-only | This field contains the number of peripheral board controllers (PBC) per data communication link (DCL). |
| I32 himDBConfHWStdSIULine | 1.3.6.1.4.1.4329.2.51.6.2.1.1.13 | Integer32 | read-only | This field contains the number of signaling unit lines. SIU: Signaling-Unit |
| I32 himDBConfHWConfLine | 1.3.6.1.4.1.4329.2.51.6.2.1.1.14 | Integer32 | read-only | This field contains the number of lines in the CONFERENCE board. |
| OCT himDBConfHWDBDim | 1.3.6.1.4.1.4329.2.51.6.2.1.1.15 | OCTET STRING | read-only | This field contains the name of the database dimensioning. |
| I32 himDBConfHWTableVer | 1.3.6.1.4.1.4329.2.51.6.2.1.1.16 | Integer32 | read-only | This field contains the version of the Conf table. |
| himHWData | 1.3.6.1.4.1.4329.2.51.6.3 | |||
| himHWDataTable | 1.3.6.1.4.1.4329.2.51.6.3.1 | not-accessible | ||
| himHWDataEntry | 1.3.6.1.4.1.4329.2.51.6.3.1.1 | not-accessible | ||
| HIM himHWDataPabxId | 1.3.6.1.4.1.4329.2.51.6.3.1.1.1 | HimPabxId | read-only | |
| OCT himHWArch | 1.3.6.1.4.1.4329.2.51.6.3.1.1.2 | OCTET STRING | read-only | This field contains the name of the hardware architecture. |
| OCT himHWArchType | 1.3.6.1.4.1.4329.2.51.6.3.1.1.3 | OCTET STRING | read-only | This field contains the name of the hardware architecture type. |
| OCT himHWOpMode | 1.3.6.1.4.1.4329.2.51.6.3.1.1.4 | OCTET STRING | read-only | This field contains the name of the operating mode. |
| OCT himHWSWUProc1 | 1.3.6.1.4.1.4329.2.51.6.3.1.1.5 | OCTET STRING | read-only | These fields contain the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B |
| OCT himHWSWUMem1 | 1.3.6.1.4.1.4329.2.51.6.3.1.1.6 | OCTET STRING | read-only | These fields contain the size of the SWU memory for each processor board. SWU = Switching Unit |
| OCT himHWSWUProc2 | 1.3.6.1.4.1.4329.2.51.6.3.1.1.7 | OCTET STRING | read-only | These fields contain the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B |
| OCT himHWSWUMem2 | 1.3.6.1.4.1.4329.2.51.6.3.1.1.8 | OCTET STRING | read-only | These fields contain the size of the SWU memory for each processor board. SWU = Switching Unit |
| OCT himHWADPProc | 1.3.6.1.4.1.4329.2.51.6.3.1.1.9 | OCTET STRING | read-only | This field contains the name of the ADP processor. |
| OCT himHWADPMem | 1.3.6.1.4.1.4329.2.51.6.3.1.1.10 | OCTET STRING | read-only | This field contains the size of memory used by the ADP. |
| himLWDataOnCB | 1.3.6.1.4.1.4329.2.51.6.4 | |||
| himLWDataOnCBTable | 1.3.6.1.4.1.4329.2.51.6.4.1 | not-accessible | ||
| himLWDataOnCBEntry | 1.3.6.1.4.1.4329.2.51.6.4.1.1 | not-accessible | ||
| HIM himLWDataOnCBPabxId | 1.3.6.1.4.1.4329.2.51.6.4.1.1.1 | HimPabxId | read-only | |
| OCT himLWOnCBAss | 1.3.6.1.4.1.4329.2.51.6.4.1.1.2 | OCTET STRING | read-only | This field contains the hardware ID of the board. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty. |
| OCT himLWOnCBPBCAddr | 1.3.6.1.4.1.4329.2.51.6.4.1.1.3 | OCTET STRING | read-only | This field contains the peripheral board controller (PBC) address of the module. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty. |
| OCT himLWOnCBFileName | 1.3.6.1.4.1.4329.2.51.6.4.1.1.4 | OCTET STRING | read-only | This field contains the filename of the loadware file. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty. |
| OCT himLWOnCBProdTime | 1.3.6.1.4.1.4329.2.51.6.4.1.1.5 | OCTET STRING | read-only | This field contains the production date of the loadware. Note:Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty. |
| himLWDataOnProc | 1.3.6.1.4.1.4329.2.51.6.5 | |||
| himLWOnProcTable | 1.3.6.1.4.1.4329.2.51.6.5.1 | not-accessible | ||
| himLWOnProcEntry | 1.3.6.1.4.1.4329.2.51.6.5.1.1 | not-accessible | ||
| HIM himLWOnProcPabxId | 1.3.6.1.4.1.4329.2.51.6.5.1.1.1 | HimPabxId | read-only | |
| OCT himLWOnProcAss | 1.3.6.1.4.1.4329.2.51.6.5.1.1.2 | OCTET STRING | read-only | This field contains the name of the directory where the file with information on Loadware resides, e. g. CCA, CCB or ADP (max. 3 characters). |
| OCT himLWOnProcInfoType | 1.3.6.1.4.1.4329.2.51.6.5.1.1.3 | OCTET STRING | read-only | This field contains the boot type. It represents the file name also. |
| OCT himLWOnProcLWId | 1.3.6.1.4.1.4329.2.51.6.5.1.1.4 | OCTET STRING | read-only | This field contains the name of the loadware. |
| OCT himLWOnProcLWIdCMP | 1.3.6.1.4.1.4329.2.51.6.5.1.1.5 | OCTET STRING | read-only | This field contains the name of the loadware ID for the CMP. This field contains the '-' character if it is not relevant to this board. |
| OCT himLWOnProcLWIdLP | 1.3.6.1.4.1.4329.2.51.6.5.1.1.6 | OCTET STRING | read-only | This field contains the name of the loadware ID for the LP. This field contains the '-' character if it is not relevant to this board. |
| himLWDataOnCSIU | 1.3.6.1.4.1.4329.2.51.6.6 | |||
| himLWOnCSIUTable | 1.3.6.1.4.1.4329.2.51.6.6.1 | not-accessible | This table contains the loadware data on the central SIU (Signaling Interface Unit). | |
| himLWOnCSIUEntry | 1.3.6.1.4.1.4329.2.51.6.6.1.1 | not-accessible | ||
| HIM himLWOnCSIUPabxId | 1.3.6.1.4.1.4329.2.51.6.6.1.1.1 | HimPabxId | read-only | |
| OCT himLWOnCSIUNominal | 1.3.6.1.4.1.4329.2.51.6.6.1.1.2 | OCTET STRING | read-only | This field contains the name of the nominal SIU (Signaling Interface Unit). |
| OCT himLWOnCSIULWNo | 1.3.6.1.4.1.4329.2.51.6.6.1.1.3 | OCTET STRING | read-only | This field contains the name of the SIU (Signaling Interface Unit) loadware. |
| OCT himLWOnCSIUProc | 1.3.6.1.4.1.4329.2.51.6.6.1.1.4 | OCTET STRING | read-only | This field contains the name of the processor in the SIU (Signaling Interface Unit). |
| OCT himLWOnCSIUSlot | 1.3.6.1.4.1.4329.2.51.6.6.1.1.5 | OCTET STRING | read-only | This field contains the name of the SIU (Signaling Interface Unit) slot. |
| OCT himLWOnCSIUActual | 1.3.6.1.4.1.4329.2.51.6.6.1.1.6 | OCTET STRING | read-only | This field contains the name of the current SIU (Signaling Interface Unit). |
| OCT himLWOnCSIUFileName | 1.3.6.1.4.1.4329.2.51.6.6.1.1.7 | OCTET STRING | read-only | This field contains the file name of the loadware file or of the initialization file. |
| OCT himLWOnCSIUFileProd | 1.3.6.1.4.1.4329.2.51.6.6.1.1.8 | OCTET STRING | read-only | This field contains the date on which the loadware or the initialization file was generated. |
| himMacAddress | 1.3.6.1.4.1.4329.2.51.6.7 | |||
| himMacAddrTable | 1.3.6.1.4.1.4329.2.51.6.7.1 | not-accessible | This table contains the C-LAN and IPDA MAC addresses which are read during the boot process. | |
| himMacAddrEntry | 1.3.6.1.4.1.4329.2.51.6.7.1.1 | not-accessible | ||
| HIM himMacAddrPabxId | 1.3.6.1.4.1.4329.2.51.6.7.1.1.1 | HimPabxId | read-only | |
| OCT himMacAddrProc | 1.3.6.1.4.1.4329.2.51.6.7.1.1.2 | OCTET STRING | read-only | This field contains the name of the processor (CCA, CCB or ADP - max 3 characters). It is also the name of the Unix directory where the file with information on MAC address resides. |
| OCT himMacAddrInfoType | 1.3.6.1.4.1.4329.2.51.6.7.1.1.3 | OCTET STRING | read-only | This field contains the condition on which the mac addresses are available. |
| MAC himMacAddrCLan | 1.3.6.1.4.1.4329.2.51.6.7.1.1.4 | MacAddress | read-only | This field contains the MAC address for UW7 part. The format is following: 'xx xx xx xx xx xx'. |
| MAC himMacAddrIPDA | 1.3.6.1.4.1.4329.2.51.6.7.1.1.5 | MacAddress | read-only | This field contains the MAC address for RMX part. The format is following: 'xx xx xx xx xx xx'. |
| himFeatures | 1.3.6.1.4.1.4329.2.51.7 | |||
| himMarketingFeatures | 1.3.6.1.4.1.4329.2.51.7.1 | |||
| himMarkFeatTable | 1.3.6.1.4.1.4329.2.51.7.1.1 | not-accessible | ||
| himMarkFeatEntry | 1.3.6.1.4.1.4329.2.51.7.1.1.1 | not-accessible | ||
| HIM himMarkFeatPabxId | 1.3.6.1.4.1.4329.2.51.7.1.1.1.1 | HimPabxId | read-only | |
| OCT himMarkFeatVer | 1.3.6.1.4.1.4329.2.51.7.1.1.1.2 | OCTET STRING | read-only | This field contains the version of the software package. Format explanation: H 2 04 | |__SW version (01=EV1.0; 02=EV2.0; 03=EV3.0; 04=HiPath 4000 V1.0; 05=HiPath 4000 V2.0; 06=HiPath 4000 V3.0) | |_____Marketing concept (1=Old, 2=New) |
| OCT himMarkFeatSerNo | 1.3.6.1.4.1.4329.2.51.7.1.1.1.3 | OCTET STRING | read-only | This field contains the serial number of the software package. |
| OCT himMarkFeatHWId | 1.3.6.1.4.1.4329.2.51.7.1.1.1.4 | OCTET STRING | read-only | This field contains the dongle ID of the hardware dongle connected. |
| OCT himMarkFeatInstallDate | 1.3.6.1.4.1.4329.2.51.7.1.1.1.5 | OCTET STRING | read-only | This field contains the date on which the code word was entered. |
| OCT himMarkFeatExpiryDate | 1.3.6.1.4.1.4329.2.51.7.1.1.1.6 | OCTET STRING | read-only | This field contains the date on which the code word will expire. |
| OCT himMarkFeatConfCode | 1.3.6.1.4.1.4329.2.51.7.1.1.1.7 | OCTET STRING | read-only | This field contains codeword entry confirmation code. |
| HIM himMarkFeatTrialModeAct | 1.3.6.1.4.1.4329.2.51.7.1.1.1.8 | HimYesNo | read-only | This field shows whether trial mode is active. Possible values: - yes - trial mode is activated - no - trial mode is not activated |
| I32 himMarkFeatTrialRemDays | 1.3.6.1.4.1.4329.2.51.7.1.1.1.9 | Integer32 | read-only | This field contains number of remaining days of an active trial mode. |
| himSalesFeatTable | 1.3.6.1.4.1.4329.2.51.7.1.2 | not-accessible | ||
| himSalesFeatEntry | 1.3.6.1.4.1.4329.2.51.7.1.2.1 | not-accessible | ||
| HIM himSalesFeatPabxId | 1.3.6.1.4.1.4329.2.51.7.1.2.1.1 | HimPabxId | read-only | |
| OCT himSalesFeatMarketPackId | 1.3.6.1.4.1.4329.2.51.7.1.2.1.2 | OCTET STRING | read-only | This column contains the CM ids of the marketing packages. |
| OCT himSalesFeatMarketPack | 1.3.6.1.4.1.4329.2.51.7.1.2.1.3 | OCTET STRING | read-only | This column contains the names of the marketing packages. |
| OCT himSalesFeatContract | 1.3.6.1.4.1.4329.2.51.7.1.2.1.4 | OCTET STRING | read-only | This column indicates whether the marketing packages have been purchased. |
| OCT himSalesFeatUsed | 1.3.6.1.4.1.4329.2.51.7.1.2.1.5 | OCTET STRING | read-only | This column indicates whether the marketing packages have been used. |
| OCT himSalesFeatFree | 1.3.6.1.4.1.4329.2.51.7.1.2.1.6 | OCTET STRING | read-only | This field contains the number of free packages. |
| OCT himSalesFeatMarkForTrial | 1.3.6.1.4.1.4329.2.51.7.1.2.1.7 | OCTET STRING | read-only | This field contains the number of packages (entites) marked for trial or blocked (if the trial mode is not active). |
| himTechFeatures | 1.3.6.1.4.1.4329.2.51.7.2 | |||
| himTechFeatTable | 1.3.6.1.4.1.4329.2.51.7.2.1 | not-accessible | ||
| himTechFeatEntry | 1.3.6.1.4.1.4329.2.51.7.2.1.1 | not-accessible | This table contains all enabled and disabled customer-specific features. Use the Object List view to display a list of all features availavle. | |
| HIM himTechFeatPabxId | 1.3.6.1.4.1.4329.2.51.7.2.1.1.1 | HimPabxId | read-only | |
| OCT himTechFeatId | 1.3.6.1.4.1.4329.2.51.7.2.1.1.2 | OCTET STRING | read-only | This field contains the CM id of the customer-specific feature. |
| OCT himTechFeatName | 1.3.6.1.4.1.4329.2.51.7.2.1.1.3 | OCTET STRING | read-only | This field contains the name of the customer-specific feature. |
| HIM himTechFeatState | 1.3.6.1.4.1.4329.2.51.7.2.1.1.4 | HimYesNo | read-only | This field contains the status of the customer-specific feature. |
| himAPSPatches | 1.3.6.1.4.1.4329.2.51.8 | |||
| himSwitchAPS | 1.3.6.1.4.1.4329.2.51.8.1 | |||
| himSwitchAPSTable | 1.3.6.1.4.1.4329.2.51.8.1.1 | not-accessible | ||
| himSwitchAPSEntry | 1.3.6.1.4.1.4329.2.51.8.1.1.1 | not-accessible | ||
| HIM himSwitchAPSPabxId | 1.3.6.1.4.1.4329.2.51.8.1.1.1.1 | HimPabxId | read-only | |
| OCT himSwitchAPSName | 1.3.6.1.4.1.4329.2.51.8.1.1.1.2 | OCTET STRING | read-only | |
| OCT himSwitchAPSCorrVer | 1.3.6.1.4.1.4329.2.51.8.1.1.1.3 | OCTET STRING | read-only | |
| OCT himSwitchAPSPartNo | 1.3.6.1.4.1.4329.2.51.8.1.1.1.4 | OCTET STRING | read-only | |
| himReplacedAMOs | 1.3.6.1.4.1.4329.2.51.8.2 | |||
| himReplAMOTable | 1.3.6.1.4.1.4329.2.51.8.2.1 | not-accessible | This table displays those AMOs that have been changed since the last system correction version. | |
| himReplAMOEntry | 1.3.6.1.4.1.4329.2.51.8.2.1.1 | not-accessible | ||
| HIM himReplAMOPabxId | 1.3.6.1.4.1.4329.2.51.8.2.1.1.1 | HimPabxId | read-only | |
| OCT himReplAMOAPS | 1.3.6.1.4.1.4329.2.51.8.2.1.1.2 | OCTET STRING | read-only | The APS in which the change has been made. |
| OCT himReplAMOName | 1.3.6.1.4.1.4329.2.51.8.2.1.1.3 | OCTET STRING | read-only | This field contains the name of the AMO command. |
| OCT himReplAMOInAPSDir | 1.3.6.1.4.1.4329.2.51.8.2.1.1.4 | OCTET STRING | read-only | This field contains the name of the subsystem in the DIR file. |
| OCT himReplAMOSubsystem | 1.3.6.1.4.1.4329.2.51.8.2.1.1.5 | OCTET STRING | read-only | This field contains the name of the current subsystem. |
| himPatchInfo | 1.3.6.1.4.1.4329.2.51.8.3 | |||
| himPatchInfoTable | 1.3.6.1.4.1.4329.2.51.8.3.1 | not-accessible | This table contains information on the software patches that have been implemented. | |
| himPatchInfoEntry | 1.3.6.1.4.1.4329.2.51.8.3.1.1 | not-accessible | ||
| HIM himPatchInfoPabxId | 1.3.6.1.4.1.4329.2.51.8.3.1.1.1 | HimPabxId | read-only | |
| OCT himPatchInfoPatchNo | 1.3.6.1.4.1.4329.2.51.8.3.1.1.2 | OCTET STRING | read-only | This field contains the number of the patch. |
| OCT himPatchInfoPatchGroup | 1.3.6.1.4.1.4329.2.51.8.3.1.1.3 | OCTET STRING | read-only | This field contains the name of the patch group. |
| HIM himPatchInfoOpt | 1.3.6.1.4.1.4329.2.51.8.3.1.1.4 | HimYesNo | read-only | This field represents an indicator that the patch is: - optional: not part of patch packet, - not optional: a part of patch packet (represents the whole list of internal activated/deactivated patches). The purpose of this field is to give user an option to display all patches as well as only optional ones. |
| OCT himPatchInfoActHD | 1.3.6.1.4.1.4329.2.51.8.3.1.1.5 | OCTET STRING | read-only | This field indicates whether the patch is enabled on the hard disk. |
| OCT himPatchInfoActADP | 1.3.6.1.4.1.4329.2.51.8.3.1.1.6 | OCTET STRING | read-only | This field indicates whether the patch is enabled on the ADP. |
| OCT himPatchInfoActBP | 1.3.6.1.4.1.4329.2.51.8.3.1.1.7 | OCTET STRING | read-only | This field indicates whether the patch is enabled on the A/B processor. |
| himSWVersion | 1.3.6.1.4.1.4329.2.51.9 | |||
| himSWVerOnProcTable | 1.3.6.1.4.1.4329.2.51.9.1 | not-accessible | This table contains data on the software versions loaded on the processor boards. | |
| himSWVerOnProcEntry | 1.3.6.1.4.1.4329.2.51.9.1.1 | not-accessible | ||
| HIM himSWVerOnProcPabxId | 1.3.6.1.4.1.4329.2.51.9.1.1.1 | HimPabxId | read-only | |
| OCT himSWVerOnProcSrc | 1.3.6.1.4.1.4329.2.51.9.1.1.2 | OCTET STRING | read-only | This field contains the name of the software source. |
| OCT himSWVerOnProcSWVer | 1.3.6.1.4.1.4329.2.51.9.1.1.3 | OCTET STRING | read-only | This field contains the name of the software version of the ADP software. The software version is displayed in the following format: [item-code-prefix][hipath-version][release-no][country-id][country-code][revision-no] e. g. P30252N 43 08 B 000 10 |
| OCT himSWVerOnProcItemCodeNoPrefix | 1.3.6.1.4.1.4329.2.51.9.1.1.4 | OCTET STRING | read-only | This field contains the prefix of the software. |
| OCT himSWVerOnProcHP4KVer | 1.3.6.1.4.1.4329.2.51.9.1.1.5 | OCTET STRING | read-only | This field contains the Hicom/HiPath version. |
| OCT himSWVerOnProcSysRel | 1.3.6.1.4.1.4329.2.51.9.1.1.6 | OCTET STRING | read-only | This field contains the system release number. |
| OCT himSWVerOnProcCountry | 1.3.6.1.4.1.4329.2.51.9.1.1.7 | OCTET STRING | read-only | This field contains the country identifier. |
| OCT himSWVerOnProcCountryCode | 1.3.6.1.4.1.4329.2.51.9.1.1.8 | OCTET STRING | read-only | This field contains the country encoding. |
| OCT himSWVerOnProcRevNo | 1.3.6.1.4.1.4329.2.51.9.1.1.9 | OCTET STRING | read-only | This field contains the revision number of the ADP software. |
| himSwPkgVersion | 1.3.6.1.4.1.4329.2.51.10 | |||
| himSWPkgVerTable | 1.3.6.1.4.1.4329.2.51.10.1 | not-accessible | This table contains the software versions of the service functions. This data is retrieved using the UNIX command pgkinfo -l. | |
| himSWPkgVerEntry | 1.3.6.1.4.1.4329.2.51.10.1.1 | not-accessible | ||
| HIM himSWPkgVerPabxId | 1.3.6.1.4.1.4329.2.51.10.1.1.1 | HimPabxId | read-only | |
| OCT himSWPkgVerPkgAbbr | 1.3.6.1.4.1.4329.2.51.10.1.1.2 | OCTET STRING | read-only | This field contains the abbreviation of the software package. |
| OCT himSWPkgVerPkgName | 1.3.6.1.4.1.4329.2.51.10.1.1.3 | OCTET STRING | read-only | This field contains the name of the software package. |
| OCT himSWPkgVerVersion | 1.3.6.1.4.1.4329.2.51.10.1.1.4 | OCTET STRING | read-only | This field contains the version of the software package. |
| OCT himSWPkgVerInstAt | 1.3.6.1.4.1.4329.2.51.10.1.1.5 | OCTET STRING | read-only | This field contains the date on which the software package was installed. |
| INT himSWPkgVerStatus | 1.3.6.1.4.1.4329.2.51.10.1.1.6 | INTEGER | read-only | This field contains the status of the software package. |
| himSystem | 1.3.6.1.4.1.4329.2.51.11 | |||
| himSysBasicTable | 1.3.6.1.4.1.4329.2.51.11.1 | not-accessible | This table complements the information about the HiPath 4000 system that is stored in the hicomSystem branch of the hicom MIB. | |
| himSysBasicEntry | 1.3.6.1.4.1.4329.2.51.11.1.1 | not-accessible | ||
| HIM himSysBasicPabxId | 1.3.6.1.4.1.4329.2.51.11.1.1.1 | HimPabxId | read-only | |
| OCT himSysBasicDomain | 1.3.6.1.4.1.4329.2.51.11.1.1.2 | OCTET STRING | read-only | This field contains the name of the domain to which the system is belonging. |
| OCT himSysBasicNodeNo | 1.3.6.1.4.1.4329.2.51.11.1.1.3 | OCTET STRING | read-only | HiPath node number. This field contains the globally unique number of your own PABX. This has a hierarchical structure containing different levels in Version V1.0 and later. Up to three values of the format: L2- L1- L0 can be used for numbering a system. - L2: area number in level 2 - L1: area number in level 1 - L0: area number in level 0 or node number in the old sense. If the value '0' is selected for a level, this means that the relevant hierarchical level is not being used for node numbering: '0' is equal to 'nothing' or 'level is not set'. With the help of this new node number format it is now possible to implement node numbers in networks in which - just as with dial numbers - the network hierarchy is reflected in the node numbers. The same numbering level (= number of levels set in the node number) must be used for all nodes in a network. This field will always show a three-level display with leading zeroes for levels not used for systems in Version V1.0 and later. Example: - 0-0-100 for 1-level numbering - 0-1-101 for 2-level numbering - 1-2-300 for 3-level numbering Values: 0-9 and '-' with format 22-111-000 Level 0 (000) 0-999 Level 1 (111) 0-253 Level 2 (22) 0-29 Max. 10 digits |
| HIM himSysBasicLEGK | 1.3.6.1.4.1.4329.2.51.11.1.1.4 | HimYesNo | read-only | This field tells if the 'LEGK' feature is activated on the system. LEGK is a process within the call processing of HiPath 4000 with the following functions: - Gate keeper function: IP address resolution mechanism for IP trunking requiring the HG3550 board as hardware. - Resource Management: This function monitors network component usage for controlling IP trunking, IPDA scenarios, HFA and direct media connections. The LEGK can be activated at every HiPath 4000 in the network. Alternatively, it can be configured on a specific HiPath 4000 system only. |
| himSysLANCardsTable | 1.3.6.1.4.1.4329.2.51.11.2 | not-accessible | ||
| himSysLANCardsEntry | 1.3.6.1.4.1.4329.2.51.11.2.1 | not-accessible | ||
| HIM himSysLANCardsPabxId | 1.3.6.1.4.1.4329.2.51.11.2.1.1 | HimPabxId | read-only | |
| IP himSysLANCardsIPAddr | 1.3.6.1.4.1.4329.2.51.11.2.1.2 | IpAddress | read-only | Unique IP address within the Customer LAN. |
| IP himSysLANCardsNetMask | 1.3.6.1.4.1.4329.2.51.11.2.1.3 | IpAddress | read-only | The netmask of the LAN card. It depends on the class of the LAN Card address. |
| IP himSysLANCardsBroadCast | 1.3.6.1.4.1.4329.2.51.11.2.1.4 | IpAddress | read-only | The broadcast address is used to send a datagram packet to all hosts of a network or subnetwork, e.g. for address propagation from a router. The broadcast address also depends on the LAN Card address. |
| INT himSysLANCardsType | 1.3.6.1.4.1.4329.2.51.11.2.1.5 | INTEGER | read-only | Type of the LAN card. Possible values are Ethernet and Token Ring. |
| INT himSysLANCardsStatus | 1.3.6.1.4.1.4329.2.51.11.2.1.6 | INTEGER | read-only | The status of the configured LAN card. Can be one of the following: - Unknown (no traffic light lit): The LAN Card is configured, but no reboot has been performed. - Enabled (green traffic light lit): The LAN Card is active. - Disabled (red traffic light lit): The LAN Card is not active. |
| himSysHostsTable | 1.3.6.1.4.1.4329.2.51.11.3 | not-accessible | ||
| himSysHostsEntry | 1.3.6.1.4.1.4329.2.51.11.3.1 | not-accessible | ||
| HIM himSysHostsPabxId | 1.3.6.1.4.1.4329.2.51.11.3.1.1 | HimPabxId | read-only | |
| I32 himSysHostsNo | 1.3.6.1.4.1.4329.2.51.11.3.1.2 | Integer32 | read-only | Index of the host entry. |
| IP himSysHostsIPAddr | 1.3.6.1.4.1.4329.2.51.11.3.1.3 | IpAddress | read-only | The IP address of the host. |
| OCT himSysHostsName | 1.3.6.1.4.1.4329.2.51.11.3.1.4 | OCTET STRING | read-only | Unique name of the host. |
| himSysWAMLConn | 1.3.6.1.4.1.4329.2.51.11.4 | |||
| himSysWAMLConnTable | 1.3.6.1.4.1.4329.2.51.11.4.1 | not-accessible | ||
| himSysWAMLConnEntry | 1.3.6.1.4.1.4329.2.51.11.4.1.1 | not-accessible | ||
| HIM himSysWAMLConnPabxId | 1.3.6.1.4.1.4329.2.51.11.4.1.1.1 | HimPabxId | read-only | |
| I32 himSysWAMLConnLTG | 1.3.6.1.4.1.4329.2.51.11.4.1.1.2 | Integer32 | read-only | Line/trunk group number. Valid values: 1-1 |
| I32 himSysWAMLConnLTU | 1.3.6.1.4.1.4329.2.51.11.4.1.1.3 | Integer32 | read-only | Line/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAML |
| I32 himSysWAMLConnSlot | 1.3.6.1.4.1.4329.2.51.11.4.1.1.4 | Integer32 | read-only | Slot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAML |
| HIM himSysWAMLConnRufNr | 1.3.6.1.4.1.4329.2.51.11.4.1.1.5 | HimPhoneNumber | read-only | Phone number of the WAML board. |
| U32 himSysWAMLConnBChl | 1.3.6.1.4.1.4329.2.51.11.4.1.1.6 | Unsigned32 | read-only | Number of b-channels on the WAML board. |
| OCT himSysWAMLConnStatus | 1.3.6.1.4.1.4329.2.51.11.4.1.1.7 | OCTET STRING | read-only | Status of the WAML board. |
| himSysWAMLConnIPTable | 1.3.6.1.4.1.4329.2.51.11.4.2 | not-accessible | ||
| himSysWAMLConnIPEntry | 1.3.6.1.4.1.4329.2.51.11.4.2.1 | not-accessible | ||
| HIM himSysWAMLConnIPPabxId | 1.3.6.1.4.1.4329.2.51.11.4.2.1.1 | HimPabxId | read-only | |
| I32 himSysWAMLConnIPLTG | 1.3.6.1.4.1.4329.2.51.11.4.2.1.2 | Integer32 | read-only | Line/trunk group number. Valid values: 1-1 |
| I32 himSysWAMLConnIPLTU | 1.3.6.1.4.1.4329.2.51.11.4.2.1.3 | Integer32 | read-only | Line/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAML |
| I32 himSysWAMLConnIPSlot | 1.3.6.1.4.1.4329.2.51.11.4.2.1.4 | Integer32 | read-only | Slot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAML |
| OCT himSysWAMLConnIPIfName | 1.3.6.1.4.1.4329.2.51.11.4.2.1.5 | OCTET STRING | read-only | Name of the interface. |
| IP himSysWAMLConnIPAddr | 1.3.6.1.4.1.4329.2.51.11.4.2.1.6 | IpAddress | read-only | IP address of the WAML connection. |
| IP himSysWAMLConnIPNetMask | 1.3.6.1.4.1.4329.2.51.11.4.2.1.7 | IpAddress | read-only | Net mask of the WAML connection. |
| himBoards | 1.3.6.1.4.1.4329.2.51.12 | |||
| himBoardBasicTable | 1.3.6.1.4.1.4329.2.51.12.1 | not-accessible | This table contains the boards that are managed by CM. It can be viewed as an extension of hicomBCSUTable. Please note that the PEN (LTG, LTU, Slot) of LTU boards is different from what is contained in CM, and uses the same format as in the hicom MIB. | |
| himBoardBasicEntry | 1.3.6.1.4.1.4329.2.51.12.1.1 | not-accessible | ||
| HIM himBoardBasicPabxId | 1.3.6.1.4.1.4329.2.51.12.1.1.1 | HimPabxId | read-only | |
| I32 himBoardBasicLTG | 1.3.6.1.4.1.4329.2.51.12.1.1.2 | Integer32 | read-only | Line/trunk group number. Valid values: 1-1 |
| I32 himBoardBasicLTU | 1.3.6.1.4.1.4329.2.51.12.1.1.3 | Integer32 | read-only | Line/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAML |
| I32 himBoardBasicSlot | 1.3.6.1.4.1.4329.2.51.12.1.1.4 | Integer32 | read-only | Slot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAML |
| I32 himBoardBasicFuncId | 1.3.6.1.4.1.4329.2.51.12.1.1.5 | Integer32 | read-only | Function ID Valid values: 0-255 2 for SIU type 2 (MFV) 3 for SIU type 3 (MFC) 4 for SIU - RDS functionality 5 for SIU - ANI signaling 6 for SIU - CIS multifrequency (MFS) 7 for SIU - line testing |
| INT himBoardBasicCat | 1.3.6.1.4.1.4329.2.51.12.1.1.6 | INTEGER | read-only | Category The board type includes: LTG -- line/trunk group LTU -- line/trunk unit PER -- peripheral module PERHW -- load peripheral hardware ACGEN -- alternating current generator DIU -- digital interface unit IPGW -- IP gateway RG -- ring generator SIUP -- signalling unit periphery TMD -- T1 boards |
| OCT himBoardBasicName | 1.3.6.1.4.1.4329.2.51.12.1.1.7 | OCTET STRING | read-only | Name of the setup the board is configured to. |
| HIM himBoardBasicVOIPSec | 1.3.6.1.4.1.4329.2.51.12.1.1.8 | HimYesNo | read-only | |
| OCT himBoardBasicLWVar | 1.3.6.1.4.1.4329.2.51.12.1.1.9 | OCTET STRING | read-only | The loadware variant. Default value: 0 Valid values: 0-9, A-D |
| I32 himBoardBasicNoCirc | 1.3.6.1.4.1.4329.2.51.12.1.1.10 | Integer32 | read-only | Number of circuits to be configured. Valid values: 1-255 |
| himBoardIPTable | 1.3.6.1.4.1.4329.2.51.12.2 | not-accessible | This table contains the IP address configuration of the boards. Please note that not all fields are used for all boards. | |
| himBoardIPEntry | 1.3.6.1.4.1.4329.2.51.12.2.1 | not-accessible | ||
| IP himBoardIPGwyIPAddr | 1.3.6.1.4.1.4329.2.51.12.2.1.1 | IpAddress | read-only | IP address of the gateway. Valid for: STMI |
| IP himBoardIPSrcIPAddr | 1.3.6.1.4.1.4329.2.51.12.2.1.2 | IpAddress | read-only | Source IP address of STMI-HFA board. A valid Source IP address must always be specified in order to enable the IP phones to address the system (SWU) Default: 0.0.0.0 Valid for: HFA |
| IP himBoardIPNetMask | 1.3.6.1.4.1.4329.2.51.12.2.1.3 | IpAddress | read-only | IP network mask. Valid for: HFA |
| IP himBoardIPDefRouter | 1.3.6.1.4.1.4329.2.51.12.2.1.4 | IpAddress | read-only | IP address of the default router within the LAN segment. The default router takes care of routing forward all packets with a destination address with a network part different from the own LAN segment. Default: 0.0.0.0 Valid for: HFA |
| IP himBoardIPCustLANIP | 1.3.6.1.4.1.4329.2.51.12.2.1.5 | IpAddress | read-only | IP address of customer LAN. Default: 0.0.0.0 Valid for: IGW, SIP |
| IP himBoardIPSTMI2IGWSubMask | 1.3.6.1.4.1.4329.2.51.12.2.1.6 | IpAddress | read-only | IP subnet mask of LAN segment. Default: 0.0.0.0 Valid for: IGW, SIP |
| IP himBoardIPDefGWIP | 1.3.6.1.4.1.4329.2.51.12.2.1.7 | IpAddress | read-only | Default gateway IP address. Default: 0.0.0.0 Valid for: IGW, SIP |
| IP himBoardIPManStatIP | 1.3.6.1.4.1.4329.2.51.12.2.1.8 | IpAddress | read-only | IP address of management station. Default: 0.0.0.0 Valid for: IGW, SIP |
| I32 himBoardIPManStatPort | 1.3.6.1.4.1.4329.2.51.12.2.1.9 | Integer32 | read-only | Port number of management station. Valid values: 1024 - 65535 Default: 0 Valid for: IGW, SIP |
| IP himBoardIPBckpServIP | 1.3.6.1.4.1.4329.2.51.12.2.1.10 | IpAddress | read-only | IP address of backup server. Default: 0.0.0.0 Valid for: IGW, SIP |
| I32 himBoardIPBckpServPort | 1.3.6.1.4.1.4329.2.51.12.2.1.11 | Integer32 | read-only | Port number of backup server. Default: 0 (0 means 'undefined port number') Valid for: IGW, SIP |
| himBoardLocTable | 1.3.6.1.4.1.4329.2.51.12.3 | not-accessible | This table contains the location data of the boards. It is only available for boards of type DSX, LTUCA, LTUCE and LTUCX. | |
| himBoardLocEntry | 1.3.6.1.4.1.4329.2.51.12.3.1 | not-accessible | ||
| I32 himBoardLocId | 1.3.6.1.4.1.4329.2.51.12.3.1.1 | Integer32 | read-only | Describes the location of the switch for the system configurator. Valid values: 0-999 |
| OCT himBoardLocLoc | 1.3.6.1.4.1.4329.2.51.12.3.1.2 | OCTET STRING | read-only | Postal address of the LTU (Line/Trunk Unit) shelf. Applies to the Local Connection Type. Valid values: text, up to 45 characters |
| HIM himBoardLocPhoneNo | 1.3.6.1.4.1.4329.2.51.12.3.1.3 | HimPhoneNumber | read-only | Phone number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters |
| HIM himBoardLocFaxNo | 1.3.6.1.4.1.4329.2.51.12.3.1.4 | HimPhoneNumber | read-only | Fax number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters |
| himIPDA | 1.3.6.1.4.1.4329.2.51.13 | |||
| himIPDAGenData | 1.3.6.1.4.1.4329.2.51.13.1 | |||
| himIPDAGenTable | 1.3.6.1.4.1.4329.2.51.13.1.1 | not-accessible | General settings that are true for all IPDAs. | |
| himIPDAGenEntry | 1.3.6.1.4.1.4329.2.51.13.1.1.1 | not-accessible | ||
| HIM himIPDAGenPabxId | 1.3.6.1.4.1.4329.2.51.13.1.1.1.1 | HimPabxId | read-only | |
| I32 himIPDAGenSpeed | 1.3.6.1.4.1.4329.2.51.13.1.1.1.2 | Integer32 | read-only | Indicates the bit-rate speed. Valid values: 10 Mbits/s; 100 Mbits/s |
| INT himIPDAGenMode | 1.3.6.1.4.1.4329.2.51.13.1.1.1.3 | INTEGER | read-only | Indicates the bit-rate mode. Valid values: Full Duplex, Half Duplex |
| I32 himIPDAGenPayConn | 1.3.6.1.4.1.4329.2.51.13.1.1.1.4 | Integer32 | read-only | TOS for VoIP payload connections to APs (CP). Valid values: 0-255 |
| I32 himIPDAGenSigConn | 1.3.6.1.4.1.4329.2.51.13.1.1.1.5 | Integer32 | read-only | TOS for signalling connections to APs (FA). Valid values: 0-255 |
| himIPDAGenIPTable | 1.3.6.1.4.1.4329.2.51.13.1.2 | not-accessible | General IP settings that are true for all IPDAs. | |
| himIPDAGenIPEntry | 1.3.6.1.4.1.4329.2.51.13.1.2.1 | not-accessible | ||
| IP himIPDAGenIPNetAddr | 1.3.6.1.4.1.4329.2.51.13.1.2.1.1 | IpAddress | read-only | IP net address of HiPath LAN segment. |
| IP himIPDAGenIPNetMask | 1.3.6.1.4.1.4329.2.51.13.1.2.1.2 | IpAddress | read-only | IP net mask of HiPath LAN segment. |
| IP himIPDAGenIPCCAAddr | 1.3.6.1.4.1.4329.2.51.13.1.2.1.3 | IpAddress | read-only | Address of the CC-A processor within the HiPath LAN segment. |
| IP himIPDAGenIPCCBAddr | 1.3.6.1.4.1.4329.2.51.13.1.2.1.4 | IpAddress | read-only | Address of the CC-B processor within the HiPath LAN segment. Default value: 0.0.0.0 |
| IP himIPDAGenIPDefRoutAddr | 1.3.6.1.4.1.4329.2.51.13.1.2.1.5 | IpAddress | read-only | IP address of the default router within the HiPath LAN segment. |
| IP himIPDAGenIPSurvNetAddr | 1.3.6.1.4.1.4329.2.51.13.1.2.1.6 | IpAddress | read-only | The IP address of the survivability net. Default value: 0.0.0.0 |
| himIPDAAPData | 1.3.6.1.4.1.4329.2.51.13.2 | |||
| himIPDABasicTable | 1.3.6.1.4.1.4329.2.51.13.2.1 | not-accessible | This table stores IPDA information from CM. | |
| himIPDABasicEntry | 1.3.6.1.4.1.4329.2.51.13.2.1.1 | not-accessible | ||
| HIM himIPDABasicPabxId | 1.3.6.1.4.1.4329.2.51.13.2.1.1.1 | HimPabxId | read-only | |
| I32 himIPDABasicLTU | 1.3.6.1.4.1.4329.2.51.13.2.1.1.2 | Integer32 | read-only | Line/trunk unit. Valid values: 17-99 |
| HIM himIPDABasicConnType | 1.3.6.1.4.1.4329.2.51.13.2.1.1.3 | HimShelfNWType | read-only | Connection type of the shelf. Valid values: APDL -- AP shelf via IP - direct linked APNW -- AP shelf via IP - network |
| I32 himIPDABasicBChanNo | 1.3.6.1.4.1.4329.2.51.13.2.1.1.4 | Integer32 | read-only | Amount of B-Channels. Valid values: 1- 120 |
| HIM himIPDABasicConvAMLaw | 1.3.6.1.4.1.4329.2.51.13.2.1.1.5 | HimYesNo | read-only | |
| himIPDAIPTable | 1.3.6.1.4.1.4329.2.51.13.2.2 | not-accessible | This table contains the IP address configuration of the IPDAs. | |
| himIPDAIPEntry | 1.3.6.1.4.1.4329.2.51.13.2.2.1 | not-accessible | ||
| IP himIPDAIPAccPtAddr | 1.3.6.1.4.1.4329.2.51.13.2.2.1.1 | IpAddress | read-only | IP address of the access point in the AP network. |
| IP himIPDAIPTAccPtAddr | 1.3.6.1.4.1.4329.2.51.13.2.2.1.2 | IpAddress | read-only | IP address for the TAP/Service PC link at the access point. This IP address must be in the same network as the access point in the AP network. |
| IP himIPDAIPAccPtRoutAddr | 1.3.6.1.4.1.4329.2.51.13.2.2.1.3 | IpAddress | read-only | IP address of the gateway (IP address of the router in the AP network). |
| IP himIPDAIPNetMaskNW | 1.3.6.1.4.1.4329.2.51.13.2.2.1.4 | IpAddress | read-only | Netmask of the network to which the respective Access Point in AP network belongs. |
| IP himIPDAIPAccPtPriRoutAddr | 1.3.6.1.4.1.4329.2.51.13.2.2.1.5 | IpAddress | read-only | IP address of the primary signalling router for NCUI board (IP address of the router in the HiPath 4000 LAN segment). Required if the connection type is APDL. |
| IP himIPDAIPNetMaskDL | 1.3.6.1.4.1.4329.2.51.13.2.2.1.6 | IpAddress | read-only | Netmask of the network to which the Access Point in AP internal network belongs. |
| himIPDALocTable | 1.3.6.1.4.1.4329.2.51.13.2.3 | not-accessible | This table contains the location data of the boards. It is only available for boards of type DSX, LTUCA, LTUCE and LTUCX. | |
| himIPDALocEntry | 1.3.6.1.4.1.4329.2.51.13.2.3.1 | not-accessible | ||
| I32 himIPDALocId | 1.3.6.1.4.1.4329.2.51.13.2.3.1.1 | Integer32 | read-only | Describes the location of the switch for the system configurator. Valid values: 0-999 |
| OCT himIPDALocLoc | 1.3.6.1.4.1.4329.2.51.13.2.3.1.2 | OCTET STRING | read-only | Postal address of the LTU (Line/Trunk Unit) shelf. Applies to the Local Connection Type. Valid values: text, up to 45 characters |
| HIM himIPDALocPhoneNo | 1.3.6.1.4.1.4329.2.51.13.2.3.1.3 | HimPhoneNumber | read-only | Phone number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters |
| HIM himIPDALocFaxNo | 1.3.6.1.4.1.4329.2.51.13.2.3.1.4 | HimPhoneNumber | read-only | Fax number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters |
| himInfo | 1.3.6.1.4.1.4329.2.51.14 | |||
| I32 himSubagentLastMsgNo | 1.3.6.1.4.1.4329.2.51.14.1 | Integer32 | read-only | The last message, warning or error number issued by the Him subagent. |
| OCT himSubagentLastMsgText | 1.3.6.1.4.1.4329.2.51.14.2 | OCTET STRING | read-only | The last message, warning or error text issued by the Him subagent. |
| I32 himResultData | 1.3.6.1.4.1.4329.2.51.14.3 | Integer32 | read-write | Is used for agent internal communication. Contains the PabxId of a Hicom for which the last discovery process was conveyed. Is SET by the discovery agent and indicates the availability of new discovered data. The new data is to be incorporated by the subagent into the subagent's data base. |
| himDiscovery | 1.3.6.1.4.1.4329.2.51.15 | |||
| C32 himChangesEx | 1.3.6.1.4.1.4329.2.51.15.1 | Counter32 | read-only | Indicates the number of finished HIM discoveries - corresponds to the number of hicomHWDiscovXXX traps sent out. |
| himDiscovTable | 1.3.6.1.4.1.4329.2.51.15.2 | not-accessible | The table describing the status concerning discovery of HIM information. | |
| himDiscovEntry | 1.3.6.1.4.1.4329.2.51.15.2.1 | not-accessible | The entry describes the status of the discovery process. It is designed to comply with the structure of discovery entries in the hicom MIB, even though data is only provided for one switch. | |
| HIM himDiscovPabxId | 1.3.6.1.4.1.4329.2.51.15.2.1.1 | HimPabxId | read-only | Unique identifier of the Hicom being discovered. |
| STR himDiscovPabxMnemonic | 1.3.6.1.4.1.4329.2.51.15.2.1.2 | DisplayString | read-only | Name of the Hicom system. |
| DIS himDiscovStatus | 1.3.6.1.4.1.4329.2.51.15.2.1.3 | DiscoveryStates | read-write | Status of discovery process. A managment station may initiate a discovery by setting this variable to value busy. The other values are set by the agent. |
| DIS himDiscovMode | 1.3.6.1.4.1.4329.2.51.15.2.1.4 | DiscoveryModes | read-write | Mode of discovery process. |
| STR himDiscovTimDat | 1.3.6.1.4.1.4329.2.51.15.2.1.5 | DisplayString | read-only | Date and time (year, month, day, hour, minute, second) the last successful discovery action was performed for the Hicom. |
| STR himDiscovErrTimDat | 1.3.6.1.4.1.4329.2.51.15.2.1.6 | DisplayString | read-only | Date and time (year, month, day, hour, minute, second) the last failed discovery action was performed for the Hicom. |
| himMibConformance | 1.3.6.1.4.1.4329.2.51.20 | |||
| himMibGroups | 1.3.6.1.4.1.4329.2.51.20.1 | |||
| himWelcomePageGroup | 1.3.6.1.4.1.4329.2.51.20.1.1 | |||
| himSwitchDataGroup | 1.3.6.1.4.1.4329.2.51.20.1.2 | |||
| himSpecGroup | 1.3.6.1.4.1.4329.2.51.20.1.3 | |||
| himSWUPeripheryGroup | 1.3.6.1.4.1.4329.2.51.20.1.4 | |||
| himCentralSwitchGroup | 1.3.6.1.4.1.4329.2.51.20.1.5 | |||
| himGeneralSwitchGroup | 1.3.6.1.4.1.4329.2.51.20.1.6 | |||
| himFeaturesGroup | 1.3.6.1.4.1.4329.2.51.20.1.7 | |||
| himAPSPatchesGroup | 1.3.6.1.4.1.4329.2.51.20.1.8 | |||
| himSWVersionGroup | 1.3.6.1.4.1.4329.2.51.20.1.9 | |||
| himSWPkgVersionGroup | 1.3.6.1.4.1.4329.2.51.20.1.10 | |||
| himSystemGroup | 1.3.6.1.4.1.4329.2.51.20.1.11 | |||
| himBoardsGroup | 1.3.6.1.4.1.4329.2.51.20.1.12 | |||
| himIPDAGroup | 1.3.6.1.4.1.4329.2.51.20.1.13 | |||
| himInfoGroup | 1.3.6.1.4.1.4329.2.51.20.1.14 | |||
| himDiscoveryGroup | 1.3.6.1.4.1.4329.2.51.20.1.15 | |||
| himTrapsGroup | 1.3.6.1.4.1.4329.2.51.20.1.16 | |||
| himTrapGroup | 1.3.6.1.4.1.4329.2.51.21 | |||
| himTrapVariables | 1.3.6.1.4.1.4329.2.51.21.1 | |||
| I32 himTrapPabxId | 1.3.6.1.4.1.4329.2.51.21.1.1 | Integer32 | not-accessible | Unique identifier of a Hicom system. |
| STR himTrapPabxMnemonic | 1.3.6.1.4.1.4329.2.51.21.1.2 | DisplayString | not-accessible | Mnemonic name of the Hicom system. |
| himTraps | 1.3.6.1.4.1.4329.2.51.21.2 | |||
| NTF internalMessageHimSubagent | 1.3.6.1.4.1.4329.2.51.21.2.0 | An internalMessage trap contains an informational message generated by the subagent. | ||
| NTF internalWarningHimSubagent | 1.3.6.1.4.1.4329.2.51.21.2.1 | An internalWarning trap contains a warning message generated by a subagent. | ||
| NTF internalErrorHimSubagent | 1.3.6.1.4.1.4329.2.51.21.2.2 | An internalError trap contains an error message generated by a subagent. After issuing this trap, the agent terminates. | ||
| NTF himDiscovSucc | 1.3.6.1.4.1.4329.2.51.21.2.10 | A himDiscovSucc trap indicates the successful termination of a discovery process. | ||
| NTF himDiscovErr | 1.3.6.1.4.1.4329.2.51.21.2.11 | A himDiscovErr trap signifies the unsuccessful termination of a discovery process. | ||
| NTF himDiscovBusy | 1.3.6.1.4.1.4329.2.51.21.2.19 | A himDiscovBusy trap signifies that a sw discovery process is running. |
RFC description
MIB for Siemens HP4K HIM (Intelligent Interface Module) system monitoring and management.
Start monitoring Siemens HiPath 4000 (HP4K) PBX host interface module (hardware architecture/software release identification) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.