All MIBs › SHE-SYSTEM-MIB › sheSystemControlRequest
sheSystemControlRequest
Module: SHE-SYSTEM-MIB
OID (symbolic): SHE-SYSTEM-MIB::sheSystemControlRequest
OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.2.1.7.1
Node type: OBJECT-TYPE
Type: SheSystemControlRequestType
Access: read-write
Description: System commands : configureTime : The command to configure the external time. tmnConnect : the command for a manager to connect in order to be allowed to manage the SHE and to stop the NE sending the sheSystemStartupEnd trap. tmnDisconnect: the command for a TMN to disconnect from the NE. lctConnect : the command for a manager to connect as a LCT. The SHE then sends the sheSystemLctSession trap. lctDisconnect: the command for a LCT to disconnect from the NE. The SHE then sends the sheSystemLctSession trap. If a LCT does not disconnect a LCT session is automatically disconnected by the SHE after a internal timer expired. writeDatatoFlash: the command to start writing configuration data of all subsystems to flash-memory (long running command). configureTimeZone: the command to change the current timezone. setCPUThreshold: the command to configure the threshold that when CPU usage exceeds the certain limit, notification is sent. setMemoryThreshold: the command to configure the threshold that when Memory usage exceeds the certain limit, notification is sent. Notifications : sheSystemStartupEnd, sheSystemLctSession, sheSystemWriteDatatoFlashFinished, sheSystemChangedCPULoadThreshold, sheSystemChangedMemoryThreshold.
What is sheSystemControlRequest?
A write-only command dispatcher: setting it to one of the enumerated codes (configureTime, tmnConnect/tmnDisconnect, lctConnect/lctDisconnect, writeDatatoFlash, configureTimeZone, setCPUThreshold, setMemoryThreshold) triggers that system action, and completion is reported via traps like sheSystemStartupEnd or sheSystemChangedCPULoadThreshold. This is the single entry point an NMS uses to issue system-level maintenance commands rather than setting scattered individual objects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.2.1.7.1 snmpwalk -v2c -c public <target> SHE-SYSTEM-MIB::sheSystemControlRequest
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.2.1.7.1.1 snmpget -v2c -c public <target> SHE-SYSTEM-MIB::sheSystemControlRequest.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.2.1.7.1.1 s <value>
Start monitoring Nokia Siemens Networks SHE DSLAM, fixed-line broadband access equipment (system config/NTP/file-management status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-SYSTEM-MIB::sheSystemControlRequest OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM, fixed-line broadband access equipment (system config/NTP/file-management status) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.7 | siemensUnits | AN-MIB |
| 1.3.6.1.4.1.231.7.1 | oenProductMibs | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2 | an | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2.2 | ppe | AN-SHE-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1 | she | AN-SHE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.7.1.2.2.1.2 | sheSystem | SHE-SYSTEM-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.2.1 | sheSystemInfo | SHE-SYSTEM-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.2.1.7 | sheSystemControl | SHE-SYSTEM-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.2.1.7.1 | sheSystemControlRequest | SHE-SYSTEM-MIB |