sheMstpBaseControlConfIdVlanIdList

Module: SHE-BRIDGE-MIB

OID (symbolic): SHE-BRIDGE-MIB::sheMstpBaseControlConfIdVlanIdList

OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.4.11.1.2.9

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: The MST configuration determines to which MST region each switch belongs. The configuration includes the name of the region, the revision number, and the MST instance-to-VLAN assignment map. For two or more switches to be in the same MST region, they must have the same VLAN-to-instance mapping, the same configuration revision number, and the same name. The sheMstpBridgeProtoParamTable holds 32 static profile entries of spanning tree protocol parameters. A profile can be used on a per-VLAN basis. This octet String with 4096 octets maps VLANs to spanning tree protocol profiles: one octet containing the sheMstpBridgeProtoParamIndex per VLAN. The octet number is the sheVlanIndex. You can assign a VLAN to only one spanning-tree instance at a time. parameter of - modifyMstpBaseConfIdVlanIdList

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.4.11.1.2.9
snmpwalk -v2c -c public <target> SHE-BRIDGE-MIB::sheMstpBaseControlConfIdVlanIdList

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.4.11.1.2.9.1
snmpget -v2c -c public <target> SHE-BRIDGE-MIB::sheMstpBaseControlConfIdVlanIdList.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.4.11.1.2.9.1 s <value>

Start monitoring Nokia Siemens Networks hiX-series DSLAM access node (bridge-port VLAN/MSTP/LAG/QoS status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-BRIDGE-MIB::sheMstpBaseControlConfIdVlanIdList OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks hiX-series DSLAM access node (bridge-port VLAN/MSTP/LAG/QoS status) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.1oenProductMibsAN-MIB
1.3.6.1.4.1.231.7.1.2anAN-MIB
1.3.6.1.4.1.231.7.1.2.2ppeAN-SHE-MIB
1.3.6.1.4.1.231.7.1.2.2.1sheAN-SHE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.1.2.2.1.4sheBridgeMibSHE-BRIDGE-MIB
1.3.6.1.4.1.231.7.1.2.2.1.4.11sheMstpConfigSHE-BRIDGE-MIB
1.3.6.1.4.1.231.7.1.2.2.1.4.11.1sheMstpBaseSHE-BRIDGE-MIB
1.3.6.1.4.1.231.7.1.2.2.1.4.11.1.2sheMstpBaseControlSHE-BRIDGE-MIB
1.3.6.1.4.1.231.7.1.2.2.1.4.11.1.2.9sheMstpBaseControlConfIdVlanIdListSHE-BRIDGE-MIB