SALIX-SYSTEM-MIB :: salixSysSyncForcedState

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SALIX-SYSTEM-MIB › salixSysSyncForcedState

salixSysSyncForcedState

Module: SALIX-SYSTEM-MIB

OID (symbolic): SALIX-SYSTEM-MIB::salixSysSyncForcedState

OID (numeric): 1.3.6.1.4.1.2158.2.3.1.5.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This variable indicates the state of the sync module with regard to switching between the configured active reference, the value of the 'salixSysSyncConfiguredActiveRef' variable, and the alternate active reference. The alternate active reference is identified by the 'salixSysSyncPrimaryRef' or 'salixSysSyncSecondaryRef' that is not configured as the 'salixSysSyncConfiguredActiveRef'.

none(0) - the sync module is in a state where it is free to switch between the configured active reference the alternate active reference.

revertiveSwitchInhibit - the state of the sync module after switching from the 'salixSysSyncConfiguredActiveRef' to the 'salixSysSyncCurrentActiveRef' when the 'salixSysSyncRevertiveSwitch' is configured as 'false'. In this state the sync module will not revert back to using the 'salixSysSyncConfiguredActiveRef' unless the 'salixSysSyncCurrentActiveRef' has failed and the state of the active reference defined by the 'salixSysSyncConfiguredActiveRef' variable is 'valid'.

autoReferenceSwitchInhibit - the state of the sync module when the 'salixSysSyncAutoReferenceSwitch' variable is configured as 'false'. In this state the sync module will not switch to using the alternate active reference unless the 'salixSysSyncCurrentActiveRef' has failed and the state of the alternate active reference is 'valid'.

What is salixSysSyncForcedState?

Reports whether the sync module is currently inhibited from switching between the configured active and alternate references: none(0) means free to switch, revertiveSwitchInhibit indicates a state after switching where revertive behavior is inhibited, and autoReferenceSwitchInhibit indicates automatic switching is blocked. An admin reads this to understand why the sync module isn't switching references even though conditions might otherwise call for it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.2.3.1.5.14
snmpwalk -v2c -c public <target> SALIX-SYSTEM-MIB::salixSysSyncForcedState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.2.3.1.5.14.1
snmpget -v2c -c public <target> SALIX-SYSTEM-MIB::salixSysSyncForcedState.1

Start monitoring SALIX Technologies media gateway/integrated access device (system error/status reporting) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-SYSTEM-MIB::salixSysSyncForcedState OID value, configure state conditions and alerts, and monitor any SALIX Technologies media gateway/integrated access device (system error/status reporting) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2158salixTechnologiesSALIX-MIB
1.3.6.1.4.1.2158.2salixGenericSALIX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2158.2.3salixSystemMIBSALIX-SYSTEM-MIB
1.3.6.1.4.1.2158.2.3.1salixSystemMIBObjectsSALIX-SYSTEM-MIB
1.3.6.1.4.1.2158.2.3.1.5salixSystemSyncSALIX-SYSTEM-MIB
1.3.6.1.4.1.2158.2.3.1.5.14salixSysSyncForcedStateSALIX-SYSTEM-MIB