SALIX-SYSTEM-MIB :: salixSysRscWorking

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SALIX-SYSTEM-MIB › salixSysRscWorking

salixSysRscWorking

Module: SALIX-SYSTEM-MIB

OID (symbolic): SALIX-SYSTEM-MIB::salixSysRscWorking

OID (numeric): 1.3.6.1.4.1.2158.2.3.1.7.1

Node type: OBJECT-TYPE

Type: PhysicalIndex

Access: read-write

Description: The PhysicalIndex of the Redundant Shelf Controller (RSC) module plug-in unit that is performing shelf controller operations in the product (ie. talking with media controller, handling SNMP requests). Writing a new value to this variable will:

- update the salixSysRscProtect object with the current value of the salixSysRscWorking object and

- activate the specified RSC module to start performing shelf controller operations in the system.

A value of 0 indicates that there is no operational shelf controller installed. Writing zero, an invalid index, or the current value to this object will have no effect.

If the working RSC module fails, the system will automatically switch to the RSC module specified in the salixRscProtect object.

What is salixSysRscWorking?

The PhysicalIndex of the Redundant Shelf Controller (RSC) module plug-in unit currently performing shelf-controller operations (media controller communication, SNMP handling); writing a new value promotes that module to working and demotes the old one to protect. A value of 0 means no operational shelf controller is installed, and if the working RSC fails, the system automatically fails over to the module identified by salixSysRscProtect.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.2.3.1.7.1
snmpwalk -v2c -c public <target> SALIX-SYSTEM-MIB::salixSysRscWorking

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.2.3.1.7.1.1
snmpget -v2c -c public <target> SALIX-SYSTEM-MIB::salixSysRscWorking.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2158.2.3.1.7.1.1 s <value>

Start monitoring SALIX Technologies media gateway/integrated access device (system error/status reporting) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-SYSTEM-MIB::salixSysRscWorking OID value, configure state conditions and alerts, and monitor any SALIX Technologies media gateway/integrated access device (system error/status reporting) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2158salixTechnologiesSALIX-MIB
1.3.6.1.4.1.2158.2salixGenericSALIX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2158.2.3salixSystemMIBSALIX-SYSTEM-MIB
1.3.6.1.4.1.2158.2.3.1salixSystemMIBObjectsSALIX-SYSTEM-MIB
1.3.6.1.4.1.2158.2.3.1.7salixSystemRscSALIX-SYSTEM-MIB
1.3.6.1.4.1.2158.2.3.1.7.1salixSysRscWorkingSALIX-SYSTEM-MIB